background image

-8 - 

 

AXTS040*-3(B)-X2

 

External pilot type 

 

         

           

 

 

Fig.4

 

  Piping for External                       

     

Fig.5

 

Piping for External   

                          pilot fluid passage 1                                          pilot fluid passage 2 

Caution 

 

The description of the sub plate and piping port do not match. Be careful with the piping 
port. 

 

For external pilot type, pulse air is only generated while pilot air is supplied.    The blow is 
constantly  stopped  by  the  return  spring  when  the  pilot  air  is  not  supplied.    Air  may  leak 
from the main valve as this is metal seal type. (Refer to Fig.4)

 

 

When  the  minimum  operating  pressure  or  more  is  supplied  to  the  X  port,  air  pulse  is 
generated  even  when  IN  port  is  pressure  is  less  than  the  minimum  operating  pressure 
(Refer to Fig.4).

  

 

When the IN port pressure constantly exceeds the minimum operating pressure, the same 
air can be connected to the IN port and X port (Refer to Fig.5).

  

 

When  the  product  is  used  in  a  condition  where  the  OUT  port  back  pressure  varies,  for 
example,  vacuum  ejector  and  /  or  suction  filter  is  connected  to  the  OUT  port,  please 
consider that the operation frequency will be changed. 

 

Keep using the plug and port with silencer. 

 

Direct manual override is operated by flat blade screwdriver. Insert the flat blade driver to 
the groove until it contacts the bottom of the groove and turn the driver 90 
degrees.   Rotating direction does not matter. Do the same for release (push and rotate for 
90 degrees). 

 

Tighten the piping using the correct torque shown below. 

 

Use an External pilot pressure higher than IN port pressure. 
 
Table.2 

Thread 

Appropriate tightening 

torque (Nm) 

1/2 

20 to 25 

AXTS040*-3(B)-X2 

Pilot air 
Control valve 

Pilot air 
Control valve 

OUT Port 
2(B) port 

OUT Port 
2(B) 

X Port      IN 

Summary of Contents for AXTS040 2 X2 Series

Page 1: ...1 Product name Pulse Blow Valve Model Series Product Number AXTS040 2 3 B X2 Doc No AXTS OMY0007 A Operation Manual SMC Corporation...

Page 2: ...4 1 Specifications P 5 2 Port size and P 5 flow characteristics 3 How to Order P 5 4 Configuration symbol P 6 5 Piping method P 7 8 6 Frequency adjustment P 9 10 7 Mounting P 11 8 Environment P 11 9 L...

Page 3: ...e when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly oper...

Page 4: ...distance or replacement parts Please consult your nearest sales branch For any failure or damage reported within the warranty period which is clearly our responsibility a replacement product or necess...

Page 5: ...oof pressure 1 5MPa Ambient and fluid temperature 20 to 60 o C Lubrication No Enclosure rating IP65 equivalent Weight About 1 400g Use an External pilot pressure higher than IN port pressure 2 Port si...

Page 6: ...r for air blow 4 A Port OUT Port 3 R2 Port Released to atmosphere pilot exhaust port with silencer AXTS040 3 B X2 Symbol for internal pilot fluid passage Fig 2 Symbol for external pilot fluid passage...

Page 7: ...ure of the OUT port will be higher due to the clogging of the filter and silencer of the vacuum ejector during operation Therefore the product cannot be used In that case please use the external pilot...

Page 8: ...minimum operating pressure the same air can be connected to the IN port and X port Refer to Fig 5 When the product is used in a condition where the OUT port back pressure varies for example vacuum eje...

Page 9: ...ne needle is adjusted the time for the opposite side will be slightly changed Internal pilot 1 to 5HZ and external pilot 1 to 8Hz is reference The charts on page 10 show the relation for the adjustmen...

Page 10: ...6 8 Hz ON 7 5 3 1 OFF AXTS040 3 B X2 ON 1 3 5 7 0 1 Hz 0 1 Hz 0 1 Hz 0 1 Hz 2 2 1 1 2 0 Hz 2 3 Hz 2 4 Hz 2 0 Hz 29 17 15 14 3 7 Hz 4 8 Hz 4 9 Hz 4 8 Hz 51 36 32 24 4 3 Hz 6 0 Hz 6 4 Hz 6 7 Hz 58 43 4...

Page 11: ...pool and sleeve which may cause the spool to stick In this situation the type of the compressor lubricating oil should be replaced with a good quality compressor lubrication oil that generates less ox...

Page 12: ...12 Revision history A Modify items in graph This manual is subject to change without prior notice 2020 SMC Corporation All Rights Reserved https www smcworld com...

Reviews: