background image

-5 - 

 

1. 

Specifications 

 

Valve construction 

Metal seal 

Fluid 

Air 

Max. operating pressure 

1.0MPa 

External pilot air pressure 

0.2 to 1.0MPa (External pilot type)   

Frequency adjustment range 

1 to 5Hz (internal pilot type) 
1 to 8Hz (external pilot type) 

Proof pressure 

1.5MPa 

Ambient and fluid temperature 

-20 to +60   

o

Lubrication 

No 

Enclosure rating 

IP65 equivalent 

Weight 

About 1,400g 

   

Use an External pilot pressure higher than IN port pressure. 

 

2. 

Port size 

 

Body port 

Flow characteristics 

Internal pilot type 

1(P)

4(A) 

External pilot type 

3(R2)

2(B) 

[dm

3

/(s

bar)] 

Cv 

[dm

3

/(s

bar)] 

Cv 

1/2 

12 

0.14 

2.9 

14 

0.18 

3.4 

This is the flow rate when the main valve is fully open. 

 

3. 

How to order 

 

 

Switching type 

Summary of Contents for AXTS040 2 X2 Series

Page 1: ...1 Product name Pulse Blow Valve Model Series Product Number AXTS040 2 3 B X2 Doc No AXTS OMY0007 A Operation Manual SMC Corporation...

Page 2: ...4 1 Specifications P 5 2 Port size and P 5 flow characteristics 3 How to Order P 5 4 Configuration symbol P 6 5 Piping method P 7 8 6 Frequency adjustment P 9 10 7 Mounting P 11 8 Environment P 11 9 L...

Page 3: ...e when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly oper...

Page 4: ...distance or replacement parts Please consult your nearest sales branch For any failure or damage reported within the warranty period which is clearly our responsibility a replacement product or necess...

Page 5: ...oof pressure 1 5MPa Ambient and fluid temperature 20 to 60 o C Lubrication No Enclosure rating IP65 equivalent Weight About 1 400g Use an External pilot pressure higher than IN port pressure 2 Port si...

Page 6: ...r for air blow 4 A Port OUT Port 3 R2 Port Released to atmosphere pilot exhaust port with silencer AXTS040 3 B X2 Symbol for internal pilot fluid passage Fig 2 Symbol for external pilot fluid passage...

Page 7: ...ure of the OUT port will be higher due to the clogging of the filter and silencer of the vacuum ejector during operation Therefore the product cannot be used In that case please use the external pilot...

Page 8: ...minimum operating pressure the same air can be connected to the IN port and X port Refer to Fig 5 When the product is used in a condition where the OUT port back pressure varies for example vacuum eje...

Page 9: ...ne needle is adjusted the time for the opposite side will be slightly changed Internal pilot 1 to 5HZ and external pilot 1 to 8Hz is reference The charts on page 10 show the relation for the adjustmen...

Page 10: ...6 8 Hz ON 7 5 3 1 OFF AXTS040 3 B X2 ON 1 3 5 7 0 1 Hz 0 1 Hz 0 1 Hz 0 1 Hz 2 2 1 1 2 0 Hz 2 3 Hz 2 4 Hz 2 0 Hz 29 17 15 14 3 7 Hz 4 8 Hz 4 9 Hz 4 8 Hz 51 36 32 24 4 3 Hz 6 0 Hz 6 4 Hz 6 7 Hz 58 43 4...

Page 11: ...pool and sleeve which may cause the spool to stick In this situation the type of the compressor lubricating oil should be replaced with a good quality compressor lubrication oil that generates less ox...

Page 12: ...12 Revision history A Modify items in graph This manual is subject to change without prior notice 2020 SMC Corporation All Rights Reserved https www smcworld com...

Reviews: