background image

DIN terminal: AV

00-

-

D, DZ

DIN terminal for European use: AV

00-

-

Y, YZ

With indicator light/

surge voltage suppressor

AV2000-

02-

G

AV2000-

02-

GS

AV2000-

02-

D

AV2000-

02-

DZ

AV2000-

02-

Y

AV2000-

02-

YZ

AV3000-

03-

G

AV3000-

03-

GS

AV3000-

03-

D

AV3000-

03-

DZ

AV3000-

03-

Y

AV3000-

03-

YZ

AV4000-

04-

G

AV4000-

04-

GS

AV4000-

04-

D

AV4000-

04-

DZ

AV4000-

04-

Y

AV4000-

04-

YZ

AV5000-

   -

G

AV5000-

   -

GS

AV5000-

   -

D

AV5000-

   -

DZ

AV5000-

   -

Y

AV5000-

   -

YZ

1/4

1/4

1/4

3/8

3/8

3/8

1/2

1/2

1/2

3/4, 1

3/4, 1

3/4, 1

  66

  66

  66

  76

  76

  76

  98

  98

  98

128

128

128

105

125

125

112

132

132

127

147

147

155

175

175

31

31

31

36

36

36

47

47

47

59

59

59

22

22

22

24

24

24

32

32

32

39

39

39

40

40

40

48

48

48

52

52

52

74

74

74

38

38

38

43

43

43

57

57

57

77

77

77

0

0

0

2

2

2

3

3

3

0

0

0

47.5

50.5

62.5

74   

Dimensions

Grommet: AV

00-

-

G, GS

SMC

MADE IN JAPAN

SMC

MADE IN JAPAN

ON

OFF

OFF

ON

300mm (lead wire length)

Manual override
(locking lever type)

Port size

36.8

E

ø37

N

C

Q

H

Pressure gauge
mounting bore 1/8

P

R

P

B

G

I

A

4-R

D

L

K

A

M

G

Applicable heavy duty cord O.D.: ø6, ø8

Manual override (locking lever type)

P

A

R

D

B

C

Q

H

Indicator light

P

4-R

36.8

E

ø37

Model

Port
size

A

B

C

D

E

G

H

I

A

Pressure
gauge
mounting
bore 1/8

65.5

67.5

68.5

70.5

80.5

82.5

90   

94   

82.5

 84.5

 85.5

 87.5

 97.5

 99.5

107   

111   

23   

10.5

27.5

16   

  3.5

20.5

6

10.5

93

100

115

143

29

29

29

28

28

28

42

42

42

50

50

50

23.5

23.5

23.5

27.5

27.5

27.5

37   

37   

37   

46   

46   

46   

M4 x 0.7

Depth 4.5

K

L

M

N

P

Q

R

M6 x 1

Depth 6

M6 x 1

Depth 7.5

M6 x 1

Depth 7.5

M6 x 1

Depth 7.5

M6 x 1

Depth 6

M6 x 1

Depth 6

M5 x 0.8

Depth 5

M5 x 0.8

Depth 5

M5 x 0.8

Depth 5

M4 x 0.7

Depth 4.5

M4 x 0.7

Depth 4.5

+

-

+

-

06

10

06

10

06

10

06

10

06

10

06

10

5

AV2000/3000/4000/5000

Summary of Contents for AV2000

Page 1: ...8 G1 2 G3 4 G1 1 5 0 2 1 0 G1 8 0 60 21 1150 39 6 2150 64 8 3500 113 6150 122 6650 A R 25 52 80 8 132 141 0 27 0 48 0 74 1 6 1 54 220 VAC 24 VDC 15 10 1 8 5 6 3 4 IP65 2 1 2 3 4 5 NBR 6 NBR 7 NBR 8 N...

Page 2: ...0 AN200 02 AN300 03 AN400 04 AN500 06 AN600 10 X31 X32 X30 KT AV2000 KT AV3000 KT AV4000 KT AV5000 SF4 5YO 80 Q SF4 4YO 80 Q P424220 01GA Y200 Y300 Y400 Y600 Y200T Y300T Y400T Y600T EAV2000 5000 0 0 1...

Page 3: ...Q EAV5000 F06 4YO Q EAVA5000 F10 EAV5000 F10 5YO Q EAV5000 F10 4YO Q EAVA EAV D F G H I J L N Q U P A R S EAV2000 G1 4 66 125 5 31 22 40 G1 8 38 0 67 5 84 5 10 5 29 23 5 4 36 8 40 EAVA2000 G1 8 24 76...

Page 4: ...109 SMC EAV2000 5000 2 3 1 R 7 1 2 5 2 3 1 4 R 6 R 1 2 1 2 _...

Page 5: ...G1 4 G3 8 G1 2 G3 4 G1 1 5 0 2 1 0 1 8 0 60 1 P 2 A 20 37 61 113 122 2 A 3 R 24 49 76 132 141 0 64 0 74 1 0 1 9 1 84 0 52 0 62 0 88 1 78 1 72 100 200 110 120 220 240 50 60 12 24 15 10 B 130 5 6 50 5...

Page 6: ...03 DZM 3 8 76 12 5 118 36 57 34 48 64 AVL4000 04 1 2 98 133 47 61 52 64 AVL4000 04 DZM 1 2 98 133 47 61 34 52 64 AVL5000 06 AVL5000 10 3 4 1 128 161 59 77 74 64 AVL5000 06 DZM AVL5000 10 DZM 3 4 1 128...

Page 7: ...pply exhaust function F R L combinations Modular with F R L combinations SMC AC2000 AC2500 AC3000 AC4000 AV2000 AV3000 AV4000 AC5000 AC6000 AV5000 F R L combination Soft start up valve Except AC4000 0...

Page 8: ...z 24VDC 12VDC Other Electrical entry G D Y Grommet Type D DIN terminal Type Y DIN terminal Indicator light Surge voltage suppressor Nil S Z None With surge voltage suppressor grommet type only With in...

Page 9: ...lever type AV4000 1 2 61 76 0 74 113 132 1 60 122 141 1 54 Secondary pressure MPa Needle valve flow characteristics Air flow l min ANR Conditions Primary pressure 0 5MPa Needle rotations Description...

Page 10: ...ntrolled by the usual meter out control When pilot valve is turned OFF spring pushes piston A and main valve upward and opens R port while shutting off the air supply from P port The pressure differen...

Page 11: ...24209A P424211 P424212 P424213 P424214 G 5 0 9 P424210 P424218 10 x 8 x 1 AV3000 P424304A P424305A P424306A P424307 P424308A P424309A P424311 P424312 P424313 P424314 STW 5 0 10 P424310 P424315 11 x 9...

Page 12: ...5 62 5 74 Dimensions Grommet AV 00 G GS SMC MADE IN JAPAN SMC MADE IN JAPAN ON OFF OFF ON 300mm lead wire length Manual override locking lever type Port size 36 8 E 37 N C Q H Pressure gauge mounting...

Page 13: ...Y30 Y40 Y60 AV2000 AV3000 AV4000 AV5000 Applicable model Model Spacer L type bracket Spacer with L type bracket Spacer with L type bracket L type bracket T type bracket Spacer with T type bracket Spac...

Page 14: ...should be performed by trained and experienced operators 3 Do not service machinery equipment or attempt to remove components until safety is confirmed 1 Inspection and maintenance of machinery equip...

Page 15: ...ulator AR2560 to 6060 With a standard regulator AR1000 to 6000 the secondary side pressure may not be released when this valve is exhausted 5 Operation of secondary side solenoid valves To operate sol...

Page 16: ...products When connecting piping to a product refer to its instruction manual to avoid mistakes regarding the supply port etc 5 F R L module combination When connecting to a modular F R L combination A...

Page 17: ...rated connected equipment will be actuated Confirm safety before operating Maintenance Warning 1 Drainage removal Remove drainage from air filters regularly Refer to specifica tions Caution 1 Do not u...