AV-SMU70EN-A 

Page 1 of 3 

 

Instruction Manual    

 

Soft Start-up Valve  

Series AV2000~5000-A 

 

 
 
 
 
 
 
 
 
 
The  intended  use  of  this  product  is  to  protect  machine  mechanism 
against sudden movement during start up. 

 

1 Safety Instructions 

These  safety  instructions  are  intended  to  prevent  hazardous  situations 
and/or  equipment  damage.  These  instructions  indicate  the  level  of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems.  

 ISO 4413: Hydraulic fluid power - General rules relating to systems. 
 IEC 60204-1: Safety of machinery - Electrical equipment of machines.     

(Part 1: General requirements) 

 ISO 10218-1: Manipulating industrial robots - Safety. etc. 

 

  Refer  to  product  catalogues,  Operation  Manual  and  Handling 

Precautions for SMC Products for additional information. 

 Keep this manual in a safe place for future reference. 

 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 
not avoided, could result in minor or moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level of risk 
which, if not avoided, could result in death or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk which, if 
not avoided, will result in death or serious injury. 

 

Warning 

 

Always  ensure  compliance  with  relevant  safety  laws  and 
standards. 

  All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

Warning 

 

 When  using  a  solenoid  valve  or  actuator  on  the  outlet  side  of  this 

product, implement appropriate measures to prevent potential danger 
caused by actuator operation. 

 This  product may  experience  air leakage  (within tolerance),  therefore 

this valve is not suitable for holding pressure in a pressure vessel for a 
long period of time. 

 This  valve  is  not  to  be  used  as  emergency  shutoff  valve.    Using  the 

valve  in  such  applications,  take  a  separate  measure  to  ensure  safe 
use. 

 Provide ventilation when using the valve in a confined area, such as in 

a closed control panel.  For example, install a ventilation opening, etc. 
in  order  to  prevent  pressure  from  increasing  inside  of  the  confined 
area and to release the heat generated by the valve. 

 The circuit designer shall ensure external cables have strain relief and 

correct protective bonding in accordance with the requirements of EN 
60204-1 

  The  circuit  designer  shall  ensure  correct  insulation  monitoring  in 

accordance with the requirements of EN60204-1. 

2 Specifications 

2.1 Mechanical Specification 

Model 

AV2000-A  AV3000-A  AV4000-A 

AV5000-A 

Port Size 

1(P), 2(A) 

1/4 

3/8 

1/2 

3/4 

3(R) 

1/4 

3/8 

1/2 

3/4 

Pressure Gauge Port Size 

1/8 

Fluid 

Air 

Ambient/Fluid Temperature 

0-50

 

Note 1)

 

Proof Pressure [MPa] 

1.5 

Operating Pressure Range [MPa] 

0.2-1.0 

Max. operating frequency 

5 cycles/min not exceeding 100 cycles/day

 

Min. operating frequency 

Once every 30 days 

Min. air quality 

5 µm filtration 

IP rating  

IP65 (DIN terminal only) 

Weight [kg] 

0.43 

0.45 

0.80 

1.30 

1.25 

F

low 

ch

a

ra

c

te

ristics

 

1(P)

–›2(A) 

C(dm

3

/s

bar) 

9.2 

13.1 

19.2 

34.8 

41.3 

0.36 

0.27 

0.32 

0.66 

0.34 

Cv 

2.4 

3.1 

5.1 

12.6 

13.7 

2(A)

–›3(R) 

C(dm

3

/s

bar) 

8.8 

9.2 

10.1 

23.7 

0.46 

0.48 

0.55 

0.67 

Cv 

2.5 

2.6 

3.2 

9.2 

Impact resistance

 

Note 2)

 

1000 m/s

2

(11ms) 

Vibration resistance

 

Note 3)

 

50 m/s

2

 (0.35mm) 

Note 1)

 Please use dry air when operating at a low temperature to avoid freezing 

Note 2)

 Two axes (horizontal and vertical) and two directions were tested and no 

malfunction of the valve occurred (pulse shape: sine shape), 3 times for each 
condition (pilot valve ON and OFF, test sample mounted with bracket) 

Note 3) 

No malfunction occurred in a sweep cycle test between 10 to 150 Hz at 

vibration sweep 0.35mm. The test was performed in the two axes and two 
directions, 7 min per cycle (20 cycles) 20 times for each condition (pilot valve ON 
and OFF) 

2.2 Electrical Specification 

Electrical Entry 

Grommet 

DIN Terminal 

Coil Rated 

Voltage [V] 

DC 

24 , 12 

AC 50/60

 

Hz 

100 , 200 , 110[115] , 220[230] 

Note1)

 

Power 

Consumption [W] 

DC 

0.35 (with light:  0.4) 

0.35(with light: 0.45) 

Allowable 

Voltage 

Fluctuation  

DC 

24V 

±10% of rated voltage 

12V 

±10% of rated voltage 

AC 

100V 

±10% of rated voltage 

110V

Note1)

 

[115V] 

±10% of rated voltage 

[-15% to +5% of rated voltage] 

200V 

±10% of rated voltage 

220V

Note1)

 

[230V] 

±10% of rated voltage 

[-15% to +5% of rated voltage] 

Apparent  Power 

[VA] 

AC 

100V 

0.78 (with light: 0.81) 

0.78(with light: 0.87) 

110V 

[115V] 

0.86 (with light: 0.89) 

[0.94 (with light: 0.97)] 

0.86(with light: 0.97) 

[0.94(with light: 1.07)] 

200V 

1.18 (with light: 1.22) 

1.15(with light: 1.30) 

220V 

[230V] 

1.30 (with light: 1.34) 

[1.42 (with light: 1.46)] 

1.27(with light: 1.46) 

[1.39(with light: 1.60)] 

Surge Voltage Suppressor 

Refer to Specific Product Precautions 3.7 

Indicator light 

LED 

LED (neon bulb for 

AC

Note  1)

 The 110VAC and 115VAC are interchangeable. The 220V AC and 230V 

AC are interchangeable as well. 

Note 2)

 Valve state is not defined if electrical input is outside of specification 

2.3 Working Principle 
Initial Operation Return Stroke 

 
 

 

 

 

 

Figure 1  

P

A

 

– outlet pressure 

P

P

 

– inlet pressure 

P

R

 

– atmospheric pressure 

Specifications - continued 

2.3.1 Low speed supply 

– 

Pilot valve ON

  

Operation 
When the pilot valve is energised, the spool is pushed down by pilot air 
and  closes  the  main  valve,  closing  the  flow  passage  to  port  3  (R).    In 
this case, force pushing the valve up is larger or equal to force pushing 
the  spool  down.    Therefore,  the  flow  path  from  the  valve  to  Port  A  is 
also kept closed. 
 
When  the  pilot  valve  turns  on,  the  piston  is  pushed  down  by  pilot  air, 
and the flow passage from the needle to Port A opens. The air pressure 
whose flow rate is adjusted by the needle flows to Port A. 
 
Cylinder actuation 
The  meter-in  control  of  the  needle  slowly  moves  cylinder  From  A  to  B 
(Figure 1). 

Pressure  
Ps

P

A

 

Ps 

– pressure for switching to rapid air supply 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.3.2 High speed supply 

– 

Solenoid valve ON

  

Operation  -When  the  outlet  side  is  filled  with  the  air  supply  from  the 
needle, P

A

 increases.  When P

A

 reaches a certain pressure level, force 

pushing the valve up is smaller than force pushing the spool down. The 
valve is pushed down, opening the flow passage and is supplied to Port 
A rapidly.  

Cylinder actuation -When Ps<P

A

 after the cylinder reaches B (Figure 1), 

the main valve fully opens and P

A

 increases rapidly as shown from C to 

D (Figure 1) and becomes the same pressure as P

P. 

Ps 

– pressure for switching to rapid air supply 

P

A

 

– outlet pressure 

Pressure 
Ps 

P

A                                                                          

 

 

2.3.3 Normal operation 

– 

Pilot valve ON

  

Operation - The valve holds the fully open condition.  
 

Specifications - continued 

Cylinder actuation - The cylinder operation is controlled by a meter-out 
circuit on the cylinder side. 
P

P

=P

A

 

2.3.4 Quick exhaust 

– 

Pilot valve OFF

  

Operation 
When the pilot valve is turned off, the pilot air of the spool is exhausted 
from the pilot valve.  The spool and the valve are returned upward due 
to  spring.  This  opens  the  flow  pressure  to  port  R  exhausting  the  air 
pressure on Port A.  
The pilot air of the piston is also exhausted from the pilot valve  and the 
piston  is  returned  upward  due  to  the  spring,  closing  the  flow  passage 
from 

the 

needle.

 

Caution 

Special  products  might  have  specifications  different  from  those  shown 
in this section. Contact SMC for specific drawings.   
 

3 Installation 

3.1  Installation 

Warning 

  Do  not  install  the  product  unless  the  safety  instructions  have 

been read and understood. 

 Stop operation if air leakage increases or the equipment does not 

operate properly. 

After  mounting  or  maintenance,  etc.,  connect  the  compressed  air  and 
power  supply,  then    perform  appropriate  function  and  leakage  tests  to 
ensure that the unit is mounted properly.  

 Operation manual/Instruction manual 

Mount  and  operate  the  product  after  reading  the  manual  carefully  and 
understanding its contents. Keep the manual in a place where it can be 
referred to as necessary. 

 

Painting and coating 

Warnings  or  specifications  printed  or  labelled  on  a  product  should  not 
be erased, removed or covered up. Please contact SMC before painting 
the  resin  parts,  as  this  may  cause  adverse  effects  depending  on  the 
solvent. 

 

Maintenance space 

Allow the sufficient space for maintenance and inspection. 
 

Warning 

 Confirm the specifications. 

The  product  presented  in  this  document  is  designed  only  for  use  in 
compressed air systems.  Do not operate at pressures or temperatures, 
etc.,  beyond  the  range  of  specifications,  as  this  can  cause  damage  or 
malfunction (refer to the specifications). 
Please contact SMC if using for any fluid other than compressed air. 

 

Operation of closed centre solenoid valves 

Even if this product is used for closed center solenoid valves or actuator 
with a load factor of 50% or more, lurching (quick extension) cannot be 
prevented. 

 Using a regulator on the outlet side 

When  mounting  a  regulator  on  the  outlet  side  (A  port  side),  use  a 
residual pressure relief regulator (AR25K to 40K) or check type  

ORIGINAL INSTRUCTIONS 

Refer to Declaration of 
Conformity for relevant 
Directives 
 

Varistor 

NO.1 

(-) (+) 

NO.2 

(+) (-) 

Coil 

LED 

 

 

 