Ground nut 

Tightening torque 

1.65 to 2.5 N

∙m 

Washer 

Grommet 

(Rubber) 

(Rating symbol) 

Refer to the catalogue for DIN 

connector part no. 

Terminal screw 

(3 locations) 

Tightening torque 

0.2 to 0.25 N∙m 

0.2 to 0.25 N

∙m 

Holding screw 
Tightening torque 
0.4 N

∙m 

Housing 

(Light mounting 
location) 

Installation - continued 

regulator.  With  a  standard  regulator  (AR10  to  60),  the  outlet  side 
pressure may not be released when this valve is exhausted. 

 Operation of solenoid valves on the outlet side 

To operate solenoid valves mounted on this product’s outlet side (A port 
side),  make  sure  that  the  outlet  side

’s  pressure  (P

A

)  has  increased  to 

the pressure equal to the inlet side (P

P

). 

 Operation 

The residual pressure release function of this product is for emergency 
use only. Avoid using this valve in the same manner as ordinary 3 port 
valves.

 

 Using a lubricator 

If  mounting  a  lubricator,  mount  it  on  the  inlet  side  (P  port  side)  of  this 
product.  If mounted on the outlet side (A port side), back flow of oil will 
occur and may spurt out of the valve

’s R port. 

 Operation for air blowing 

This product cannot be operated for air blowing due to the mechanism 
that  switches  the  main  valve  to  be  fully  open  after  the  outlet  side

’s 

pressure increases to approximately 1/2 of the inlet side. 
 

  

Warning 

 

Solenoid valve for 200, 220VAC 

The  AC  solenoid  valves  with  grommet  have  a  built-in  rectifier  circuit  in 
the pilot section to operate the DC coil. 
With  200V  and  220  VAC  pilot  valves,  this  built-in  rectifier  generates 
heat when energised.  The surface may become hot depending on the 
energised condition.  To prevent burns, do not touch the solenoid valve. 
 

3.2  Environment 

Warning 

  Do not use in an environment where corrosive gases, chemicals, sea 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications.  

  Do not mount in a location exposed to radiant heat that would result 

in temperatures in excess of the product’s specifications 

  Take  suitable  protective  measures  if  water,  oil  or  welding  spatter  is 

likely to adhere to the valve. 

  Take measures to ensure air quality, such as by installing an 

aftercooler, air dryer, or water separator. Compressed air that contains 
a large amount of drainage can cause a malfunction of pneumatic 
equipment such as valves. Therefore, take appropriate measures to 
ensure air quality, such as by providing an aftercooler, air dryer, or 
water separator. 

  Take  suitable  measures  to  prevent  dust  or  noise  if  operating  in  an 

environment  generating  dust  or  intrusive  valve  switching  noise,  by 
providing a silencer in the R port. 

Caution 

 Low temperature operation 

Although  the  valve  can  be  operated  at  temperature  as  low  as  0°C, 
measures should be taken to avoid solidifying or freezing drainage and 
moisture.  

3.3  Piping 

Caution 

 Before connecting piping make sure to clean up chips, cutting oil, dust 

etc.  

  When  installing  piping  or  fittings,  ensure  sealant  material  does  not 

enter inside the port. When using seal tape, leave 1.5-2 thread ridges 
exposed on the end of the pipe/fitting.  

  Refer  to  the  instruction  manual/operation  manual  during  installation 

and make sure to connect to the correct supply port, etc.  

 

F.R.L module combination 

When connecting to a modular F.R.L. unit (AC20 to 60), select one of 
the  spacers,  included  amongst  the  accessories.    However,  modular 
combinations with AC40-06 are not possible. 

 

Installation - continued 

Furthermore, connect soft start-up valves to the outlet side of the F.R.L. 
combination. 

 

Inlet side piping conditions 

The  nominal  size  of 

the  piping  material’s  or  equipment’s  bore  should 

be  equal  to  or  larger  than  the  soft  start-

up  valve’s  port  size.    The 

combined sonic conductance of the inlet side’s (P port side’s) piping or 
equipment should be equal to or larger than the values below. 

Model 

Combined sonic conductance 

[dm

3

/(s

·bar)] 

AV2000-A 

AV3000-A 

22 

AV4000-A 

35 

AV5000-A 

50 

When the piping is restricted or the supply pressure is insufficient, the 
main valve will not switch and air leakage may occur from the R port. 

  Tighten fittings to the specified tightening torque. 

Connecting threads 

Proper tightening torque (N

▪m) 

Rc 1/4 

12 to 14 

Rc 3/8 

22 to 24 

Rc 1/2 

28 to 30 

Rc 3/4 

28 to 30 

Rc 1 

36 to 38 

3.4  Lubrication 

Caution 

  The  valve  has  been  lubricated  for  life  at  the  factory,  and  does  not 

require any further lubrication. 

  If a lubricant is used in the system, refer to catalogue for details. 

Once lubricant is utilized within the system, since the original lubricant 
applied  within the  product  during manufacturing  will  be  washed  away, 
please continue to supply lubrication to the system. Without continued 
lubrication, malfunctions could occur. If turbine oil is used, refer to the 
corresponding Material Safety Data Sheet (MSDS). 

  Lubrication amount 

If  a  lubricant  is  applied  excessively,  it may  accumulate  inside the  pilot 

valve,  causing  malfunction  or  delayed  response.    Avoid  using  large 
amount  of  lubricant.    If  it  is  not  avoidable,  use  an  external  pilot  type, 
whereby  supply  air  to  the  external  pilot  port  contains  no  oil.  This 
prevents accumulation of oil inside the pilot valve. 

3.5  Wiring 

Caution 

  When  electric  power  is  connected  to  a  solenoid  valve,  make  sure  to 

apply correct voltage.  Incorrect voltage may cause malfunction or coil 
damage. 

  Check the connections. 

Check if the connections are correct after completing all wiring. 

  External force applied to lead wire 

An  excessive  force  to  the  lead  wire  may  cause  wire  breakage.    Take 
appropriate measures to avoid applying a force of 30 N or more to the 
lead wire. 

  Voltage leakage  

Particularly when using a C-R element (surge voltage suppressor) to 
protect the switching element, take note that leakage current will flow 
through the C-R element, increasing leakage voltage.   

 

AC coil is 8% or less of rated voltage. 
DC coil is 3% or less of rated voltage. 

3.6  Air supply 

Caution 

  Install air filters close to the valve on the upstream side. 

  Implement countermeasures  by  installing  after-cooler  or  air dryer,  or 

water separator, etc. 

 

Installation - continued 

The compressed air containing a large amount of moisture may result in 
a malfunction of the valve and other pneumatic equipment.  Install an 
after-cooler, air dryer or water separator or otherwise take an 
appropriate measure. 

3.7  Surge voltage suppressor 

Caution 

3.7.1 DC power supply 

3.7.1.1 Grommet 

– standard type (with polarity)  

 With light/surge voltage suppressor (

Z) 

 

 

NOTE1:

 Connect correctly the lead wires to + (positive) and - (negative) 

indications on the connector. 

NOTE2:

  Solenoids,  whose  lead  wires  have  been  pre-wired:  positive 

side (+) is red and negative side (-) is black. 
 

3.7.1.2 DIN Terminal 

With light/surge voltage suppressor (DZ) 
DIN terminal has no polarity. 
 

3.7.2 AC power supply 

3.7.2.1 Grommet 

 With light (GZ) 

 
 
 
 

 
3.7.2.2 DIN Terminal

 

With light (DZ) and (YZ) 

 
 
 
 
 
 
  
NOTE1: 

Surge  voltage  suppressor  of  varistor  has  residual  voltage 

corresponding  to  the  protective  element  and  rated  voltage;  therefore, 
protect the controller side from the surge voltage.  The residual voltage 
of the diode is approximately 1V.

 

 
3.8  How to use DIN terminal 

3.8.1 Construction 
Type “Y” 

Y type DIN connector is a DIN connector that confirms to the DIN pitch 
8-mm standard. 

Type “D” 

D  type  DIN  connector  with  9.4  mm  pitch  between  terminals  is  not 
interchangeable with Y type connector. 

 To  distinguish  between 

“Y”  and  “D”  type  DIN  connector,  “Y”  has  “N” 

listed at the end of voltage symbol.  For connector parts without lights, 
“N” is not indicated. Refer to the name plate to distinguish. 

 

“Y” Dimensions are the same as “D” type DIN connector.  

 When  exchanging  the  pilot  valve  assembly  only, 

V115K-

D-X400

 

is interchangeable with 

V115K-

Y-X400

.  Do not replace 

V111K-

G-X400

 with 

V115-

D/

Y-X400

 (DIN terminal), and vice versa. 

 

3.8.2 Connection  

1.  Loosen the holding screw and pull the connector out of the solenoid 

valve terminal block. 

 

Installation - continued 

2.  After removing the holding screw, insert a flat head screwdriver, etc. 

into  the  notch  on  the  bottom  of  the  terminal  block  and  pry  it  open, 
separating the terminal block and the housing. 

3.  Loosen the screw (slotted screws) on the terminal block. Insert the 

lead  cores  wires  into  the  terminals  according  to  the  connection 
method, and secure the wires by re-tightening the terminal screw. 

4.  Secure the cord by tightening the gland nut. 
 

Caution 

 

When  making  connections,  take  note  that  using  other  than  the 
supported  size  (

ø

3.5  to 

ø

7)  heavy  duty  cord  will  not  meet  IP65 

(enclosure)  standards.  Ensure  to  tighten  the  gland  nut  and  holding 
screw within their specified torque ranges.

 

3.8.3 Changing the entry direction  

After separating the  terminal  block  and  housing,  the cord  entry  can  be 
changed  by  attaching the  housing  in the  desired  direction  (4  directions 
at 90° intervals). 
*When equipped with light, handle carefully to avoid damage to the light 
with the lead wires in the cable. 

NOTE: 

Plug in and pull out the connector vertically without tilting to one 

side. 

3.8.4 Compatible cable 

Cable O.D.: 

ø

3.5 to 

ø

(Reference) 0.5mm

2

, 2-core or 3-core, equivalent to JIS C 3306 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

3.8.5 DIN Connector part numbers 

Type 

Option 

Rated Voltage 

Rated Symbol 

Part number 

“D” Type  Without light 

SY100-61-1 

With light 

24 VDC 

24 V 

SY100-61-3-05 

12 VDC 

12 V 

SY100-61-3-06 

100 VAC 

100 V 

SY100-61-2-01 

200 VAC 

200 V 

SY100-61-2-02 

110 VAC 

110 V 

SY100-61-2-03 

220 VAC 

220 V 

SY100-61-2-04 

“Y” Type 

Without light 

SY100-82-1 

With light 

24VDC 

24 VN 

SY100-82-3-05 

12VCD 

12 VN 

SY100-82-3-06 

100VAC 

100 VN 

SY100-82-2-01 

200VAC 

200 VN 

SY100-82-2-02 

110VAC(115VAC) 

110 VN 

SY100-82-2-03 

220VAC(230VAC) 

220 VN 

SY100-82-2-04 

3.8.6 Circuit Diagram with light 

 

 

 

 

 

 

Coil 

 

Coil 

 

NL: neon bulb 

 

Notch 
Figure of 
notch. 

Terminal block 