![SMC Networks AC20 B Series Operation Manual Download Page 13](http://html1.mh-extra.com/html/smc-networks/ac20-b-series/ac20-b-series_operation-manual_1299104013.webp)
3-2. AC20A-D to AC60A-D
-12-
AC20A-D
AC30A-D
AC40A-D
AC40A-06-D
AC50A-D
AC60A-D
Filter regulator
[AW]
AW20-D
AW30-D
AW40-D
AW40-06-D
AW60-D
AW60-D
Lubricator
[AL]
AL20-D
AL30-D
AL40-D
AL40-06-D
AL50-D
AL60-D
1/8, 1/4
1/4, 3/8
1/4, 3/8, 1/2
3/4
3/4, 1
1
[AW]
N.C.
[AW]
0.1 MPa
N.O.
[AW]
-
[AW]
[AW]
[AW]
8 cm
3
25 cm
3
[AL]
15 L/min(ANR)
Port size 1/4: 30 L/min(ANR)
Port size 3/8: 40 L/min(ANR)
Port size 1/4: 30 L/min(ANR)
Port size 3/8: 40 L/min(ANR)
Port size 1/2: 50 L/min(ANR)
50 L/min(ANR)
190 L/min(ANR)
220 L/min(ANR)
[AL]
25 cm
3
55 cm
3
[AL]
[AW/AL]
[AW/AL]
Semi-standard (Steel)
[AW]
Weight
0.31 kg
0.58 kg
1.12 kg
1.22 kg
2.90 kg
2.97 kg
The compressed air quality class on the inlet side is [7:4:4].
5
μ
m
ISO8573-1:2010 [6:4:-]
45 cm
3
0.15 MPa
0.1 MPa
Drain capacity
Min. dripping flow rate
Note 4)
Oil capacity
Recommended lubricant
Bowl guard
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square enbedded type pressure gauge or with a digital pressure switch.
Note 2) -5 to 50
o
C for the products with the digital pressure switch.
Note 3) Based on ISO8573-1:2010 Compressed air - Part 1: Contaminants and purity classes.
Note 4) - The flow rate is 5 drops/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20
o
C; Oil adjustment valve fully open.
135 cm
3
Construction
Standard (Polycarbonate)
Relieving type
- For a circuit that repeatedly turns ON and OFF on the outlet side, make the adjustment so that the average air consumption per minute becomes
equal to the minimum dripping flow rate or more.
Model
Component
Port size
Pressure gauge port size
Note 1)
1/8
Set pressure range
Filtration rating
Class 1 turbine oil (ISO VG32)
Polycarbonate
Fluid
Ambient and fluid temperature
Note 2)
Min. operating
pressure of auto
drain
Compressed air quality class
Note 3)
Bowl material
Proof pressure
Max. operating pressure
Air
-5 to 60
o
C (with no freezing)
1.5 MPa
1.0 MPa
0.05 to 0.85 MPa