![SMC Networks AC20 B Series Operation Manual Download Page 12](http://html1.mh-extra.com/html/smc-networks/ac20-b-series/ac20-b-series_operation-manual_1299104012.webp)
2. Application
3. Standard Specifications
3-1. AC20-D to AC60-D
This product is used in combination with components which aim to eliminate a certain amount of water vapor and
solid foreign matter in the air line, lubricating and controlling pressure of pneumatic products or solenoid valves.
-11-
AC20-D
AC30-D
AC40-D
AC40-06-D
AC50-D
AC60-D
Air filter
[AF]
AF20-D
AF30-D
AF40-D
AF40-06-D
AF50-D
AF60-D
Regulator
[AR]
AR20-D
AR30-D
AR40-D
AR40-06-D
AR50-D
AR60-D
Lubricator
[AL]
AL20-D
AL30-D
AL40-D
AL40-06-D
AL50-D
AL60-D
1/8, 1/4
1/4, 3/8
1/4, 3/8, 1/2
3/4
3/4, 1
1
[AR]
N.C.
[AF]
0.1 MPa
N.O.
[AF]
-
[AR]
[AF]
[AF]
8 cm
3
25 cm
3
[AL]
15 L/min (ANR)
Port size 1/4: 30 L/min(ANR)
Port size 3/8: 40 L/min(ANR)
Port size 1/4: 30 L/min(ANR)
Port size 3/8: 40 L/min(ANR)
Port size 1/2: 50 L/min(ANR)
50 L/min(ANR)
190 L/min(ANR)
220 L/min(ANR)
[AL]
25 cm
3
55 cm
3
[AL]
[AF/AL]
[AF/AL]
Semi-standard (Steel)
[AR]
0.38 kg
0.75 kg
1.42 kg
1.55 kg
3.34 kg
3.60 kg
Note 2) -5 to 50
o
C for the products with the digital pressure switch.
Note 3) Based on ISO8573-1:2010 Compressed air - Part 1: Contaminants and purity classes.
The compressed air quality class on the inlet side is [7:4:4].
Construction
Weight
Filtration rating
Compressed air quality class
Note 3)
Drain capacity
Min. dripping flow rate
Note 4)
Set pressure range
Ambient and fluid temperature
Note 2)
Proof pressure
Fluid
Model
Component
Port size
Pressure gauge port size
Note 1)
Max. operating pressure
- For a circuit that repeatedly turns ON and OFF on the outlet side, make the adjustment so that the average air consumption per minute becomes
equal to the minimum dripping flow rate or more.
Oil capacity
Recommended lubricant
Bowl material
Bowl guard
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square enbedded type pressure gauge or with a digital pressure switch.
Note 4) - The flow rate is 5 drops/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20
o
C; Oil adjustment valve fully open.
Class 1 turbine oil (ISO VG32)
Min. operating
pressure of auto
drain
Polycarbonate
Standard (Polycarbonate)
Relieving type
0.15 MPa
0.1 MPa
0.05 to 0.85 MPa
5
μ
m
ISO8573-1:2010 [6:4:-]
45 cm
3
135 cm
3
1/8
Air
-5 to 60
o
C (with no freezing)
1.5 MPa
1.0 MPa