S
PECIFICATIONS
C-2
Size
44.0 x 41.5 x 4.4 cm (17.4 x 16.4 x 1.8 in.)
Temperature
Operating: 0 °C to 50 °C (32 °F to 122 °F)
Storage: -40 °C to 70 °C (-40°F to 158°F)
Humidity
Operating: 5% to 95% (non-condensing)
AC Input
100 to 240 V, 50-60 Hz, 1.4A
Power Supply
Internal, auto-ranging transformer: 100 to 240 VAC, 47/63 Hz, 3A
External, supports a 14-pin connection for a redundant power supply
Power Consumption
150 Watts maximum
Maximum Current
1.6 A @ 110 VAC
0.6 A @ 230 VAC
Switch Features
Forwarding Mode
Store-and-forward
Throughput
Wire speed
Flow Control
Full Duplex: IEEE 802.3-2005
Half Duplex: Back pressure