A
BOUT
THE
T
IGER
S
WITCH
1-6
Optional Redundant Power Unit
The switch supports an optional Redundant Power Unit (RPU) that can
supply power to the switch in the event of failure of the internal power
supply.
Power Supply Sockets
There are two power sockets on the rear panel of the switch. The standard
power socket is for the AC power cord. The socket labeled “RPU” is for the
optional Redundant Power Unit (RPU).
Table 1-2 System Status LEDs
LED
Condition
Status
Power
On Green
Internal power supply is operating normally.
On Amber
Internal power supply has failed.
Off
Power off or failure.
Diag
On Green
System self-diagnostic test successfully
completed.
On Amber
System self-diagnostic test in progress.
Flashing Amber
System self-diagnostic test has failed.
RPU
On Green
Redundant power available.
Flashing Green
Operating on redundant power.
On Amber
Fault in redundant power unit.
Off
There is no redundant power unit currently
attached.
Module 1 /
Module 2
On Green
Module present and operating normally.
On Amber
Module present but cannot be accessed or has
failed.
Off
Module not present.