T
ROUBLESHOOTING
A-2
Diagnosing Power Problems with the LEDs
The Power and RPU LEDs work in combination to indicate power status
as follows.
Power and Cooling Problems
If the power indicator does not turn on when the power cord is plugged in,
you may have a problem with the power outlet, power cord, or internal
power supply. However, if the unit powers off after running for a while,
check for loose power connections, power losses or surges at the power
outlet. If you still cannot isolate the problem, the internal power supply
may be defective.
Installation
Verify that all system components have been properly installed. If one or
more components appear to be malfunctioning (such as the power cord or
network cabling), test them in an alternate environment where you are sure
that all the other components are functioning properly.
Table A-2 Power/RPU LEDs
Power LED RPU LED Status
Green
Green
Internal power functioning normally; RPU is present.
Green
Amber
Internal power functioning normally; RPU plugged in but
faulty.
Green
Off
Internal power functioning normally; RPU not plugged in.
Amber
Green
Internal power faulty; RPU delivering power.
Off
Off
Both internal power and RPU unplugged or not functioning.