C
ABLES
B-2
10BASE-T/100BASE-TX Pin Assignments
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for
RJ-45 connections: 100-ohm Category 3 or better cable for 10 Mbps
connections, or 100-ohm Category 5 or better cable for 100 Mbps
connections. Also be sure that the length of any twisted-pair connection does
not exceed 100 meters (328 feet).
The RJ-45 ports on the switch base unit support automatic MDI/MDI-X
operation, so you can use straight-through cables for all network connections
to PCs or servers, or to other switches or hubs. In straight-through cable,
pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to
pins 1, 2, 3, and 6 at the other end of the cable. When using any RJ-45 port
on this switch, you can use either straight-through or crossover cable.
Table B-1 10/100BASE-TX MDI and MDI-X Port Pinouts
Pin
MDI Signal Name
MDI-X Signal Name
1
Transmit Data plus (TD+)
Receive Data plus (RD+)
2
Transmit Data minus (TD-) Receive Data minus (RD-)
3
Receive Data plus (RD+)
Transmit Data plus (TD+)
6
Receive Data minus (RD-)
Transmit Data minus (TD-)
4,5,7,8
Not used
Not used
Note:
The “+” and “-” signs represent the polarity of the wires that
make up each wire pair.
Summary of Contents for 8724M INT - annexe 1
Page 2: ......
Page 20: ...FIGURES xvi ...
Page 30: ...ABOUT THE TIGERSTACK 10 100 1 10 ...
Page 48: ...INSTALLING THE SWITCH 3 12 ...
Page 70: ...SPECIFICATIONS C 4 ...
Page 72: ...ORDERING INFORMATION D 2 ...
Page 78: ...GLOSSARY Glossary 6 ...
Page 82: ......