1000BASE-T Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections
should also work for 1000BASE-T, providing that all four wire pairs are
connected. However, it is recommended that for all critical connections, or
any new cable installations, Category 5e (enhanced Category 5) or
Category 6 cable should be used. The Category 5e and 6 specifications
include test parameters that are only recommendations for Category 5.
Therefore, the first step in preparing existing Category 5 cabling for
running 1000BASE-T is a simple test of the cable installation to be sure
that it complies with the IEEE 802.3-2002 standards.
Cable Testing for Existing Category 5 Cable
Installed Category 5 cabling must pass tests for Attenuation, Near-End
Crosstalk (NEXT), and Far-End Crosstalk (FEXT). This cable testing
information is specified in the ANSI/TIA/EIA-TSB-67 standard.
Additionally, cables must also pass test parameters for Return Loss and
Equal-Level Far-End Crosstalk (ELFEXT). These tests are specified in the
ANSI/TIA/EIA-TSB-95 Bulletin, “The Additional Transmission
Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”
Note that when testing your cable installation, be sure to include all patch
Table B-2 1000BASE-T MDI and MDI-X Port Pinouts
Pin
MDI Signal Name
MDI-X Signal Name
1
Bi-directional Data One Plus (BI_D1+)
Bi-directional Data Two Plus (BI_D2+)
2
Bi-directional Data One Minus (BI_D1-)
Bi-directional Data Two Minus (BI_D2-)
3
Bi-directional Data Two Plus (BI_D2+)
Bi-directional Data One Plus (BI_D1+)
4
Bi-directional Data Three Plus (BI_D3+)
Bi-directional Data Four Plus (BI_D4+)
5
Bi-directional Data Three Minus (BI_D3-)
Bi-directional Data Four Minus (BI_D4-)
6
Bi-directional Data Two Minus (BI_D2-)
Bi-directional Data One Minus (BI_D1-)
7
Bi-directional Data Four Plus (BI_D4+)
Bi-directional Data Three Plus (BI_D3+)
8
Bi-directional Data Four Minus (BI_D4-)
Bi-directional Data Three Minus (BI_D3-)
Summary of Contents for 6752AL2 - annexe 1
Page 2: ......
Page 14: ...COMPLIANCES x ...
Page 20: ...FIGURES xvi ...
Page 28: ...ABOUT THE TIGERSWITCH 10 100 1 8 ...
Page 44: ...INSTALLING THE SWITCH 3 10 ...
Page 56: ...TROUBLESHOOTING A 4 ...
Page 68: ...ORDERING INFORMATION D 2 ...
Page 74: ...Glossary 6 ...
Page 78: ...INDEX Index 4 ...
Page 79: ......