1000BASE-T Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections
should also work for 1000BASE-T, providing that all four wire pairs are
connected. However, it is recommended that for all critical connections, or
any new cable installations, Category 5e (enhanced Category 5) or
Category 6 cable should be used. The Category 5e and 6 specifications
include test parameters that are only recommendations for Category 5.
Therefore, the first step in preparing existing Category 5 cabling for
running 1000BASE-T is a simple test of the cable installation to be sure
that it complies with the IEEE 802.3-2002 standards.
1000 Mbps Gigabit Ethernet Collision Domain
Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length
Cable Type
Maximum Cable
Length
Connector
Category 5, 5e, or 6 100-ohm UTP
or STP
100 m (328 ft)
RJ-45
Table 4-2 Maximum 1000BASE-SX Gigabit Ethernet Cable Lengths
Fiber Size
Fiber
Bandwidth
Maximum Cable
Length
Connector
62.5/125 micron
multimode fiber
160 MHz/km
2-220 m (7-722 ft)
LC
200 MHz/km
2-275 m (7-902 ft)
LC
50/125 micron
multimode fiber
400 MHz/km
2-500 m (7-1641 ft)
LC
500 MHz/km
2-550 m (7-1805 ft)
LC
Summary of Contents for 6752AL2 - annexe 1
Page 2: ......
Page 14: ...COMPLIANCES x ...
Page 20: ...FIGURES xvi ...
Page 28: ...ABOUT THE TIGERSWITCH 10 100 1 8 ...
Page 44: ...INSTALLING THE SWITCH 3 10 ...
Page 56: ...TROUBLESHOOTING A 4 ...
Page 68: ...ORDERING INFORMATION D 2 ...
Page 74: ...Glossary 6 ...
Page 78: ...INDEX Index 4 ...
Page 79: ......