T
ROUBLESHOOTING
A-2
Diagnosing Power Problems with the LEDs
The Power and RPU LEDs work in combination to indicate power status
as follows.
Power and Cooling Problems
If the power indicator does not turn on when the power cord is plugged in,
you may have a problem with the power outlet, power cord, or internal
power supply. However, if the unit powers off after running for a while,
check for loose power connections, power losses or surges at the power
outlet. If you still cannot isolate the problem, the internal power supply
may be defective.
Installation
Verify that all system components have been properly installed. If one or
more components appear to be malfunctioning (such as the power cord or
network cabling), test them in an alternate environment where you are sure
that all the other components are functioning properly.
Table A-2 Power/RPU LEDs
LED
Condition
Status
PWR
Green
Internal power functioning normally.
Amber
Internal power faulty.
Off
The unit has no power connected or has failed.
RPU
Green
A redundant power unit is attached and is in backup or
active mode.
Amber
There is a fault in the redundant power unit.
Off
There is no redundant power unit currently attached.
Summary of Contents for 6752AL2 - annexe 1
Page 2: ......
Page 14: ...COMPLIANCES x ...
Page 20: ...FIGURES xvi ...
Page 28: ...ABOUT THE TIGERSWITCH 10 100 1 8 ...
Page 44: ...INSTALLING THE SWITCH 3 10 ...
Page 56: ...TROUBLESHOOTING A 4 ...
Page 68: ...ORDERING INFORMATION D 2 ...
Page 74: ...Glossary 6 ...
Page 78: ...INDEX Index 4 ...
Page 79: ......