Advanced Configuration
6-35
6
Logging Level
– Sets the minimum severity level for event logging.
(Default: Informational)
The system allows you to limit the messages that are logged by specifying a
minimum severity level. The following table lists the error message levels from the
most severe (Emergency) to least severe (Debug). The message levels that are
logged include the specified minimum level up to the Emergency level.
Note:
The access point error log can be viewed using the Event Logs window in the
Status section (page 6-92). The Event Logs window displays the last 128
messages logged in chronological order, from the newest to the oldest. Log
messages saved in the access point’s memory are erased when the device is
rebooted.
Logging Facility Type
– Sets the facility type for remote logging of syslog messages.
The command specifies the facility type tag sent in syslog messages. (See RFC
3164.) This type has no effect on the kind of messages reported by the switch.
However, it may be used by the syslog server to sort messages or to store
messages in the corresponding database. (Range: 16-23; Default: 16)
Error Level
Description
Emergency
System unusable
Alerts
Immediate action needed
Critical
Critical conditions (e.g., memory allocation, or free memory error - resource
exhausted)
Error
Error conditions (e.g., invalid input, default used)
Warning
Warning conditions (e.g., return false, unexpected return)
Notice
Normal but significant condition, such as cold start
Informational
Informational messages only
Debug
Debugging messages
Summary of Contents for 2555W-AG2
Page 1: ...USER GUIDE EliteConnectTM Universal 802 11a g 2 4GHz 5GHz Wireless Access Point SMC2555W AG2...
Page 6: ...vi...
Page 18: ...COMPLIANCES xii...
Page 26: ...xx Contents...
Page 38: ...Introduction 1 12 1...
Page 54: ...Initial Configuration 5 4 5 The home page displays the Main Menu...
Page 62: ...System Configuration 6 8 6...
Page 302: ...Glossary 6 Glossary...
Page 307: ......