Display
High Temperature Fluid Type (For Water)
Functions:
PF2A, PF2W
Refer to the operation manual how to set and to operate.
Flow rate measurement selection
Real-time flow rate and accumulated flow rate can be selected.
Up to 999999 of flow rate value can be accumulated.
Unit switching
Display
Real-time flow rate
l
/min
CFM x 10
–2
,
CFM x 10
–1
Accumulated flow
l
ft
3
x 10
–1
For Air
CFM = ft
3
/min
High Flow Rate Type (For Air)
Display
Real-time flow rate
l
/min
CFM
Accumulated flow
l
, m
3
, m
3
x 10
3
ft
3
, ft
3
x
10
3
, ft
3
x
10
6
Real-time flow rate
l
/min
GPM
Accumulated flow
l
gal (US)
GPM
=
gal (US)/min
Note) Fixed SI unit [
l
/min or
l
] will be set for the type
without the unit switching function.
Note 1) Applicable for all integrated display types other than series
PF2A7
H and remote type sensor display units.
Note 2) Only for series PF2A7
H.
Flow rate conversion
Basic state: 0
°
C, 101.3 kPa
Standard state: 20
°
C, 101.3 kPa, 65%RH (ANR)
Switchable between these states.
Flow rate measuring unit confirmation
This function allows to confirm the accumulated flow rate
when real-time flow rate is selected and to confirm the
real-time flow rate when accumulated flow rate is selected.
Error correction
LED display
Contents
Solution
Note 2)
Note 2)
Note 1)
Note 1)
Note 1)
Note 1)
Note 2)
A current of more than
80mA is flowing to OUT1
A current of more than
80mA is flowing to OUT2.
The setting data has
changed for whatever
reasons.
The flow rate is over the
flow rate measurement
range (for air only).
Check the load and wiring
for OUT1.
Check the load and wiring
for OUT2.
Perform the RESET
operation, and reset all
data again.
Reduce the flow rate until it
is within the flow rate
measurement range, using
an adjustment valve.
Key lock
This function prevents incorrect operations such as
changing the set value accidentally.
Accumulation clearance
This is to clear the accumulated value.
Initialization of setting (Only for series PF2A7
H)
This is to restore the setting to the initial state when
dispatched from the factory.
Real-time switch output ( )
Output types
Real-time switch output, accumulated switch output, or
accumulated pulse output can be selected as an output type.
YES
NO
YES
NO
“P”
OUT1
Output
mode
•
Window comparator mode
H: Hysteresis
•
Window comparator mode
H: Hysteresis
• Hysteresis mode
• Hysteresis mode
ON
OFF
P-1
P-2
ON
OFF
n-1
n-2
ON
OFF
P-1
P-2
H
H
H
H
ON
OFF
n-2
n-1
High flow rate
→
High flow rate
→
High flow rate
→
High flow rate
→
∗
OUT2 is the same.
“n”
Accumulated switch output ( )
“P”
OUT1
Output
mode
ON
OFF
P-3
High flow rate
→
“n”
ON
OFF
n-3
High flow rate
→
Note 1)
Accumulated pulse output ( )
50 msec
ON
OFF
ON
OFF
“P”
OUT1
Output
mode
“n”
Note 1)
Note 1) Output mode is set
to inverted output at
the factory before
shipment.
Note 1) Output mode is set to inverted output at the
factory before shipment.
Note 1) For digital flow switch with unit switching function.
(Fixed SI unit [
l
/min, or
l
, m
3
or m
3
x 10
3
] will be set
for switch types without unit switching function.)
Refer to the specifications of display unit for the flow
rate value per pulse.
16-11-31
ZSE
ISE
PSE
Z
I
SE3
PS
Z
I
SE
1
2
ZSP
ISA2
IS
ZSM
PF2
IF
Data
Digital Flow Switch
Series
PF2A/PF2W