1. 

To avoid reversed connections of the air inlet/outlet, make 

connections after confirming the "IN/OUT" mark or arrows that 
indicate the direction of air flow. Reversed connections can cause 
malfunction. 

2. 

Components with a bowl, e.g., air filter, filter regulator must be 

installed vertically with the bowl downward so that faulty drain 
discharge and dripping can be verified.

3. 

Ensure  sufficient  top,  bottom,  and  front  clearance  for 

maintenance and operation of each component. Refer to the 
dimensions section for the minimum clearance for each 
component.

4. Regulator and filter regulator

Be sure to unlock the knob before adjusting the pressure and to 
lock it after the pressure is set. 

5. Drain piping

1) The drain guide bowl of a filter or filter regulator is not provided 

with a valve function to exhaust drainage. Install valves onto 
the drain guide before supplying air to discharge air and 
drainage.

2) When piping the drain guide bowl of the filter or filter regulator, 

first secure the drain guide with a wrench. Failure to secure the 
drain guide may result in bowl damage.

1. When there is excessive drainage

Install the dryer or water separator (Drain Catch) before the air 
filter or filter regulator.

Air supply

Adjustment

1. Regulator and filter regulator

1) Set the regulator while verifying the displayed values of the 

inlet and outlet pressure gauges. Turning the knob excessively 
can cause damage to the internal parts.

2) Do not use a tool on the pressure regulator knob as this can 

cause damage. It must be operated manually. 

1. Regulator and filter regulator

1) Be sure to check the inlet pressure before setting the outlet 

pressure.

2)  The pressure gauge included with regulators for 0.02 to 0.2 

MPa setting is for up to 0.2 MPa only. Do not apply pressure 
exceeding 0.2 MPa.  It can damage the pressure gauge.

3)  To set the pressure using the knob, turn the knob in the 

direction that increases pressure and lock the knob after the 
pressure is set. If this is done in the direction that decreases 
pressure, the pressure may drop from the original set 
pressure. Turning the knob clockwise increases the outlet 
pressure, and turning it counterclockwise reduces the 
pressure. 

1.

  To screw piping materials into components, tighten with a 

recommended tightening torque while holding the female thread 
side. If the minimum tightening torque is not observed, this can 
cause a looseness and seal failure. On the other hand, excess 
tightening torque can cause damage to the thread. Furthermore, 
tightening without holding the female thread side can cause 
damage due to the excess force that is applied directly to the 
piping bracket.

F.R. Precautions 2

Be sure to read before handling. 

Recommended tightening torque

Torque

1/4

12 to 14

1/8

7 to 9

3/4

28 to 30

1

36 to 38

3/8

22 to 24

1/2

28 to 30

Unit: N·m

801

Warning

Caution

Caution

Caution

Piping

Warning

Connection

thread

Summary of Contents for 10-AW Series

Page 1: ...This product is for overseas use only according to the new Measurement Law The SI unit type is provided for use in Japan Accessory Optional specifications Accessory Optional specifications Combination B G H 1 2 6 8 C J N R Z 10 21 AW20 B G H 1 2 6 8 C N R J Z 10 21 AW30 40 Applicable filter regulator Optional specifications Accessory Symbol Air 1 5 MPa 1 0 MPa 0 05 to 0 85 MPa Set pressure 0 05 MP...

Page 2: ...x 1 5 Model 1 8 1 4 1 4 3 8 1 4 3 8 1 2 3 4 Pressure gauge port size 1 8 1 8 1 4 1 4 Bracket mounting size Panel mount Optional specifications B 164 B 167 208 246 249 B 228 266 269 With bowl guard Metal bowl Metal bowl with level gauge Pressure gauge Option Min clearance for maintenance Min clearance for maintenance Pressure gauge port size Z Y T S A F Q N AA W Bracket Option Drain Drain Applicabl...

Page 3: ...oduct is for overseas use only according to the new Measurement Law The SI unit type is provided for use in Japan Accessory Optional specifications Accessory Optional specifications Combination B G H 1 2 6 8 C J N R Z 10 21 AW20K B G H 1 2 6 8 C N R J Z 10 21 AW30K 40K Applicable filter regulator with backflow mechanism Optional specifications Accessory Symbol Air 1 5 MPa 1 0 MPa 0 05 to 0 85 MPa ...

Page 4: ...uge AW20K AW30K to 40K 06 Pressure gauge Option Clearance for maintenance Clearance for maintenance Pressure gauge port size T S A F Q N AA Bracket Option Drain Applicable tubing ø6 4 J K D U M ø44 G V P C B H 1 8 Hexagon width across flats 14 Port size OUT Pressure gauge Option Pressure gauge port size ø44 T S Q AA N Bracket Option A F Applicable tubing ø6 4 OUT J M D K U E G V P C B H 1 4 Hexago...

Page 5: ...nd filter regulator Air consumption is 0 1 l min ANR or less under standard specifications Please consult with SMC if this value is not allowable 1 The grease 10 Fluorine 21 Mineral used on internal sliding parts and seals may run down to outlet side components Please consult with SMC if this is not desirable 2 Regulator and filter regulator 1 Residual pressure release outlet pressure release is n...

Page 6: ...1 Regulator and filter regulator 1 Set the regulator while verifying the displayed values of the inlet and outlet pressure gauges Turning the knob excessively can cause damage to the internal parts 2 Do not use a tool on the pressure regulator knob as this can cause damage It must be operated manually 1 Regulator and filter regulator 1 Be sure to check the inlet pressure before setting the outlet ...

Page 7: ...ter 1 Replace the element every 2 years or when the pressure drop becomes 0 1 MPa whichever comes first to prevent damage to the element 2 Release accumulated condensate periodically before it reaches the maximum capacity Condensate that flows out to the outlet side can cause malfunctions 5 Mist separator and micro mist separator 1 Replace the element every 2 years or when the pressure drop become...