background image

F.R. Precautions 3

Be sure to read before handling. 

Maintenance

1.

  When  disassembly  or  installation  is  required  during  the 

maintenance, repair, or replacement of a device, be sure to follow 
the instructions provided in the instruction manual or safety 
instructions in this catalog.

2.

 Perform periodical inspections to detect any cracks, scratches, or 

other deterioration of the transparent resin bowl of the air filter 
and filter regulator. 
Replace with a new bowl or metal bowl when any kind of 
deterioration is found, otherwise this can cause damage.

3.

  Perform periodical inspections to detect dirt on the transparent 

resin bowl of the air filter and filter regulator. When you find dirt 
on any of the above devices, clean with a household neutral 
detergent. Do not use other cleaning agents, otherwise this can 
cause damage.

4. Air filter

1) Replace the element every 2 years or when the pressure drop 

becomes 0.1 MPa, whichever comes first, to prevent damage 
to the element.

2) Release accumulated condensate periodically before it reaches 

the maximum capacity. Condensate that flows out to the outlet 
side can cause malfunctions.

5. Mist separator and micro mist separator

1) Replace the element every 2 years or when the pressure drop 

becomes 0.1 MPa, whichever comes first, to prevent damage 
to the element.

2) Release accumulated condensate periodically before it reaches 

the maximum capacity. Condensate that flows out to the outlet 
side can cause malfunctions.

1.

 Perform periodical inspections of the filter element and replace it 

as necessary. Check the element whenever the outlet pressure 
drops below normal or air does not flow smoothly during 
operation.

2. Regulator and filter regulator

Check the sliding part or seat of the internal valve when a setting 
malfunction or relief leakage occur and temporary or emergency 
repairs need to be made. 

802

Warning

Caution

Summary of Contents for 10-AW Series

Page 1: ...This product is for overseas use only according to the new Measurement Law The SI unit type is provided for use in Japan Accessory Optional specifications Accessory Optional specifications Combination B G H 1 2 6 8 C J N R Z 10 21 AW20 B G H 1 2 6 8 C N R J Z 10 21 AW30 40 Applicable filter regulator Optional specifications Accessory Symbol Air 1 5 MPa 1 0 MPa 0 05 to 0 85 MPa Set pressure 0 05 MP...

Page 2: ...x 1 5 Model 1 8 1 4 1 4 3 8 1 4 3 8 1 2 3 4 Pressure gauge port size 1 8 1 8 1 4 1 4 Bracket mounting size Panel mount Optional specifications B 164 B 167 208 246 249 B 228 266 269 With bowl guard Metal bowl Metal bowl with level gauge Pressure gauge Option Min clearance for maintenance Min clearance for maintenance Pressure gauge port size Z Y T S A F Q N AA W Bracket Option Drain Drain Applicabl...

Page 3: ...oduct is for overseas use only according to the new Measurement Law The SI unit type is provided for use in Japan Accessory Optional specifications Accessory Optional specifications Combination B G H 1 2 6 8 C J N R Z 10 21 AW20K B G H 1 2 6 8 C N R J Z 10 21 AW30K 40K Applicable filter regulator with backflow mechanism Optional specifications Accessory Symbol Air 1 5 MPa 1 0 MPa 0 05 to 0 85 MPa ...

Page 4: ...uge AW20K AW30K to 40K 06 Pressure gauge Option Clearance for maintenance Clearance for maintenance Pressure gauge port size T S A F Q N AA Bracket Option Drain Applicable tubing ø6 4 J K D U M ø44 G V P C B H 1 8 Hexagon width across flats 14 Port size OUT Pressure gauge Option Pressure gauge port size ø44 T S Q AA N Bracket Option A F Applicable tubing ø6 4 OUT J M D K U E G V P C B H 1 4 Hexago...

Page 5: ...nd filter regulator Air consumption is 0 1 l min ANR or less under standard specifications Please consult with SMC if this value is not allowable 1 The grease 10 Fluorine 21 Mineral used on internal sliding parts and seals may run down to outlet side components Please consult with SMC if this is not desirable 2 Regulator and filter regulator 1 Residual pressure release outlet pressure release is n...

Page 6: ...1 Regulator and filter regulator 1 Set the regulator while verifying the displayed values of the inlet and outlet pressure gauges Turning the knob excessively can cause damage to the internal parts 2 Do not use a tool on the pressure regulator knob as this can cause damage It must be operated manually 1 Regulator and filter regulator 1 Be sure to check the inlet pressure before setting the outlet ...

Page 7: ...ter 1 Replace the element every 2 years or when the pressure drop becomes 0 1 MPa whichever comes first to prevent damage to the element 2 Release accumulated condensate periodically before it reaches the maximum capacity Condensate that flows out to the outlet side can cause malfunctions 5 Mist separator and micro mist separator 1 Replace the element every 2 years or when the pressure drop become...