background image

1.  Safety  Instrutions 

-1- 

 

Membrane Air Dryer 
Safety Instructions

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These  instructions  indicate  the  level  of  potential  hazard  with  the  labels  of  “Caution,”  “Warning”  or 
“Danger.”

 

They  are  all  important  notes  for  safety  and  must  be  followed  in  addition  to  International  Standards 
(ISO/IEC)

*1)

, and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

   

ISO 10218-1992: Manipulating industrial robots -Safety.

                                                                                 

 

 

  etc.

 

 
 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning

 

Warning 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

 

Danger 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

 

1.  The  compatibility  of  the  product  is  the  responsibility  of  the  person  who  designs  the 

equipment or decides its specifications.

 

Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The  assembly,  operation  and  maintenance  of  machines  or  equipment  including  our  products  must  be 
performed by an operator who is appropriately trained and experienced.

 

3.  Do  not  service  or  attempt  to  remove  product  and  machinery/equipment  until  safety  is 

confirmed.

 

1.The  inspection  and  maintenance  of  machinery/equipment  should  only  be  performed  after  measures  to 

prevent falling or runaway of the driven objects have been confirmed.

 

2.When  the  product  is  to  be  removed,  confirm  that  the  safety  measures  as  mentioned  above  are 

implementedand the power from any appropriate source is cut, and read and understand the specific product 
precautions of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the product is 

to be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to   

direct sunlight.

 

2.  Installation  on  equipment  in  conjunction  with  atomic  energy,  railways,  air  navigation,  space,  shipping, 

vehicles,  military,  medical  treatment,  combustion  and  recreation,  or  equipment  in  contact  with  food  and 
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other 
applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety 

analysis.

 

4.Use  in  an  interlock  circuit,  which  requires  the  provision  of  double  interlock  for  possible  failure  by  using  a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

Summary of Contents for IDG5*V4-***-*-X032 Series

Page 1: ...eries Product Number IDG3 V4 X032 IDG5 V4 X032 IDG10 V4 X032 IDG20 V4 X032 IDG30 AV4 X032 IDG50 AV4 X032 IDG60 AV4 X032 IDG75 AV4 X032 IDG100 AV4 X032 Contents 1 Safety Instructions 1 2 Installations and Operations 3 3 Maintenance and Checks 5 4 Specifications 6 ...

Page 2: ... possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or ...

Page 3: ...d due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product due to the use ...

Page 4: ... This time can be shortened as described below 1 Provide a valve on the outlet side of the membrane air dryer 2 Supply air with the valve closed so that only purge air flows through the membrane air dryer 3 After 15 minutes or more open the valve and let air flow to the outlet side equipment Selection Caution a Consider the purge air flow rate in total flow rate requirements Find the purge air flo...

Page 5: ... a customer Connection thread size Proper tightening torque N m 1 8 7 to 9 1 4 12 to 14 Air Supply Caution a Compressed air supply capacity An air source that has a supply capacity that is larger than the necessary outlet air flow rate dry air flow rate purge air flow rate is required See the purge air flow rate diagram in the catalog for the purge air flow rate b Avoid chemical substances which h...

Page 6: ...of the dew point indicator changes 2 Use a dew point meter for confirming the correct dew point Discoloration other than above Absorbent is used for the dew point indicator The absorbent absorbs vaporized oil or other gas components which cannot be eliminated by micro mist separator and the dew point indicator may turn colors other than specified above In this case it is difficult to check the hum...

Page 7: ...ate 1 L min ANR In the case of inlet air pressure 0 7MPa 25 25 Ambient temperature o C 25 Inlet air temperature o C Inlet air saturation temperature o C Port size Mass kg 1 8 1 4 1 4 3 8 1 8 1 4 1 4 3 8 20 Outlet air flow rate L min ANR Y4 0 T A Y2 0 T A 5 to 55 5 to 55 5 to 50 5 to 50 Spacer Compressed Air 0 7 Fluid 15 5 to 55 5 to 55 5 to 50 5 to 50 0 3 to 1 0 0 3 to 0 85 Model Specifications Ra...

Page 8: ...298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2018 SMC Corporation All Rights Reserved Revision history A Changes to Maintenance and Checks B Correction of specification column ...