Smartgen HAT163 User Manual Download Page 17

                              

HAT163 ATS CONTROLLER USER MANUAL 

HAT163 ATS Controller                          2018-05-20                          Version 1.0                        Page 17 of 21 

 

Fig.6 

– VITZRO/FEITENG ATS Apllication Drawing 

NOTE: Please conference the above drawings for wiring. The actual wiring on site is subject to the ATS switch 

wiring instructions. And the capacity of the fuse should be selected according to the actual power consumption at 

the site, which cannot be based on the fuse capacity in the drawing.   

Summary of Contents for HAT163

Page 1: ...HAT163 ATS CONTROLLER USER MANUAL SMARTGEN ZHENGZHOU TECHNOLOGY CO LTD ...

Page 2: ...aterial form including photocopying or storing in any medium by electronic means or other without the written permission of the copyright holder Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above Any reference to trademarked product names used within this publication is owned by their ...

Page 3: ...R DESCRIPTION 7 4 4 OPERATION 7 4 4 1 AUTO MANUAL MODE SWITCH 7 4 4 2 MANUAL OPERATION 7 4 4 3 AUTO OPERATION 8 4 4 4 MANUAL TEST 8 5 CLOSE FAULT ALARM 8 6 CONNECTION 8 7 DEFINITION AND RANGE OF PARAMETERS 10 8 PARAMETERS SETTING 13 8 1 PARAMETERS SETTING MODE 13 8 2 PARAMETERS SETTING 13 8 3 RESET TO DEFAULT 14 9 TYPICAL APPLICATION 15 10 OVERALL DIMENSION AND PANEL CUTOUT 19 10 1CASE DIMENSION 1...

Page 4: ... Phase voltage Ua Ub Uc Phase voltage Ua Ub Uc Line voltage Uab Ubc Uca Line voltage Uab Ubc Uca Frequency Hz Frequency Hz With over under voltage over under frequency loss of phase and phase rotation detection functions LEDs on the panel can clearly display ATS working status Auto Manual mode can be switched In manual mode ATS can be switched by pressing front panel button With one force open inp...

Page 5: ...10A 250VAC Volt free output Normally open 2 Close Relay 10A 250VAC Volt free output Normally open Breaker Open Relay 7A 250VAC Volt free output Normally open Oil Engine Start Relay 7A 250VAC Volt free output Normally close LO NO Relay 10A 250VAC Active output Communication LINK interface MODBUS RTU Protocol Case Dimensions 86 9mmx158mmx119 5mm Panel Cutout 73 5mmx144mm Working Conditions Temperatu...

Page 6: ... mode by pressing for 8s 1 Close Numerical increase 1 close in manual mode Adjust parameters in parameter configuration mode 2 Close Numerical decrease 2 close in manual mode Adjust parameters in parameter configuration mode Open Used for opening breaker in manual mode Test Confirm It is active in manual mode While genset start signal is energizing press this button can deactivate the start genset...

Page 7: ...nual mode Genset Status Lamp illuminates genset start signal outputs Lamp flashes genset start signal de energized 4 4 OPERATION 4 4 1 AUTO MANUAL MODE SWITCH When the controller is normally working if auto manual mode indicator is off it means controller is in manual mode it can switch into auto mode by pressing the indicator will be normally light then press again to switch back to manual mode N...

Page 8: ... active alarm indicator flashed with 5Hz frequency simultaneously controller switches ATS to breaking position when force open input is inactive controller closes opens breaker normally 6 WIRE CONNECTION Fig 2 Controller Rear Panel Drawing Table 5 Terminals Description No Items Function Description Remark 1 N2 2 AC 3 phase 4 wire input Single phase connect with A2 and N2 B2 and C2 are not connecte...

Page 9: ... Rated capacity 10A 250VAC 13 2 Close Relay Volt free normally open contact output Rated capacity 10A 250VAC 14 Open Output Volt free normally open contact output Rated capacity 7A 250VAC 15 NO Rated capacity 10A 250VAC 16 LO Rated capacity 10A 250VAC 17 FO IN Force open input when active transfer ATS to breaking position Ground is active 18 1 Close Input Detect 1 breaker close status auxiliary co...

Page 10: ...hase 3 Wire 2P3W 2 S1 Normal Delay 1 7 2 1 1s 2 5s 3 10s 4 20s 5 30s 6 45s 7 User defined Default 5s 3 S2 Normal Delay 1 7 2 1 1s 2 5s 3 10s 4 20s 5 30s 6 45s 7 User defined Default 5s 4 S1 Abnormal Delay 1 7 2 1 1s 2 5s 3 10s 4 20s 5 30s 6 45s 7 User defined Default 5s 5 S2 Abnormal Delay 1 7 2 1 1s 2 5s 3 10s 4 20s 5 30s 6 45s 7 User defined Default 5s 6 Close Delay 1 7 4 1 Continuous Close Enab...

Page 11: ... this form can be set via computers and slave b When delay is 7 User defined parameter delay must be set via computer If parameter is not set via computer the delay is Default if parameter has been set via computer then the delay is the set value Table 7 Parameters Definition and Range Table 2 No Item Range Default Description 1 Rated Voltage 170 270 V 230 Provide base for over under volt judge 2 ...

Page 12: ...turn Value 100 120 104 Return value 12 Under Frequency Warn 0 1 1 0 Disabled 1 Enabled 13 Under Frequency Set Value 80 100 90 Threshold value 14 Under Frequency Return Value 80 100 96 Return value 15 Loss of Phase 0 1 1 0 Disabled 1 Enabled fixed delay as 3s 16 Phase Sequence Wrong 0 1 0 0 Disabled 1 Enabled fixed delay as 3s 17 Module Address 1 254 1 Address that communicates with PC software NOT...

Page 13: ...indicators mean these parameter values currently parameter value is 1 Configurable parameter list please check Table 6 Parameters Definition and Range Table 1 of item 7 Specific settings are as below 1 Select setting number which needs to adjust by pressing and 2 Enter into setting status by pressing and indicator flashes 3 After set this parameter by pressing and and press the key to save the val...

Page 14: ... Value 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 9 10 11 12 8 3 RESET TO DEFAULT In parameter setting mode press and LEDs illuminated and LED flashes After pressing LED illuminates for 2s indicating that the factory value has been restored Meanwhile all LEDs flash for 3 times and return back to the normal mode NOTE if needn t to restore to factory value press to return to the normal mode after LED flashes ...

Page 15: ...HAT163 ATS CONTROLLER USER MANUAL HAT163 ATS Controller 2018 05 20 Version 1 0 Page 15 of 21 9 TYPICAL APPLICATION Fig 4 ATyS d M Application Drawing ...

Page 16: ...HAT163 ATS CONTROLLER USER MANUAL HAT163 ATS Controller 2018 05 20 Version 1 0 Page 16 of 21 Fig 5 ATyS d Application Drawing ...

Page 17: ...G ATS Apllication Drawing NOTE Please conference the above drawings for wiring The actual wiring on site is subject to the ATS switch wiring instructions And the capacity of the fuse should be selected according to the actual power consumption at the site which cannot be based on the fuse capacity in the drawing ...

Page 18: ...tion is 10A 250VAC if using LO NO as ATS s power supply the max circuit current of ATS is 10A Fig 8 2 Phase 3 Wire Connection Fig 9 Single Phase 2 Wire Connection NOTE The above drawing shows the wiring method is the AC phase voltage of 220V If the AC phase voltage is 110V in actual use please contact our technical personnel to confirm the specific wiring method ...

Page 19: ... 10 OVERALL DIMENSION AND PANEL CUTOUT 10 1 CASE DIMENSION Unit mm Fig 10 Overall Dimensions 10 2 CUTOUT The controller has three installation ways panel built in internal 35mm slideway and internal screw mounting Panel built in and internal screw mounting are as below Fig 11 Cutout Dimensions ...

Page 20: ... ATS CONTROLLER USER MANUAL HAT163 ATS Controller 2018 05 20 Version 1 0 Page 20 of 21 10 3 INSTALLATION Fig 12 Panel Built in Installation Fig 13 35mm Sideway Installation Fig 14 Internal Screw Installation ...

Page 21: ...rative Check connections and voltages of 1 and 2 power Check F1 or F2 fuse Controller displays normal but switch not activate Check ATS Check the connections between controller and ATS 1 or 2 power LED flashes Check whether AC voltage is normal or not Alarm LED flashes If switch close failure alarms please check switch auxiliary contact wiring _________________________________ ...

Reviews: