background image

GP Series 

 

15 

©2013 Smarter Tools, Inc. All Rights Reserved

 

Installation (cont’d) 

______________________________________________________________________________________________ 
 

Add Fuel 

1. 

Use clean, fresh, regular unleaded fuel with a minimum octane rating of 85. 

2. 

DO NOT mix oil with fuel. 

3. 

Clean area around the fuel cap. 

4. 

Remove the fuel cap. 

5. 

Be sure that the fuel strainer is in place. 

6. 

Slowly add fuel to the tank. DO NOT overfill. Allow approximately ¼ inch of space for fuel expansion. 

7. 

DO NOT fill above fuel strainer. 

8. 

Screw on the fuel cap and wipe away and spilled fuel. 

 
WARNING: 

 

THE GENERATOR MUST BE OFF AND COOLED DOWN BEFORE REFILLING THE FUEL TANK. 

 

 

 

 

 

 

 

 

Note: 

For DEB models read preface for propane connection and safety instructions

.

 

 

Summary of Contents for ST-GP4750EB

Page 1: ...Owner s Manual ST GP4750EB WARNING To Reduce Risk of Injury User Must Read and Understand Owner s Manual Prior to Use NOTE Retain Original Sales Receipt as Proof of Purchase ...

Page 2: ...s as well as date and place of purchase for future reference Have this information available when ordering parts and when making technical or warranty inquiries Smarter Tools Customer Service 1 888 241 8498 Model Number GP 4750 E EB Serial Number Date of Purchase Purchase Location ...

Page 3: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ___________________________...

Page 4: ...arting Watts 4750w Rated Frequency 60HZ Rated Voltage 120V Rated Current 30A Run Time 10hrs at 50 load Receptacles qty 2 120V AC 20A 1 120V 30A RV 1 120V 30A AC 1 12V 8A DC Net Gross Weight 92 105lbs Noise Level dB 72dB Fuel Type Unleaded gasoline Fuel Capacity gal 4 Fuel Gauge Yes Oil Type SAE 10W 30 20 oz 62 Qt Start Type Electric Recoil AC Volt Meter Yes Frame Construction Tubular Steel Wheel H...

Page 5: ...r 1 Fuel Gauge Indicates amount of fuel in tank 2 Fuel Tank 4 gallon capacity 3 Choke Used to start engine 4 Fuel Valve Turn this valve to the on position to supply fuel to the engine 5 Air Filter Protects the engine by filtering dust and debris from the intake air 6 Recoil Starter Used to start the engine 7 Low Oil Shutdown Senses the level of oil in the crankcase and shuts the engine down if the...

Page 6: ...Protects the generator against electrical overload 4 120V 20A Duplex This duplex is protected by a 20A circuit breaker Use this duplex to operate 120 volt AC single phase 60 Hz loads requiring up to 20 A or 2400 Watts of power 5 120V 30A Twist Lock This receptacle powers 120 Volt AC 60 Hz single phase loads requiring up to 30A or 3600 Watts of power 6 120V 30A RV Outlet This receptacle powers a RV...

Page 7: ...l 15 Operation 16 Starting 16 Surge Protection 16 Capacity 17 Power Management 18 Connecting Electrical Loads 18 Stopping the Engine 18 Wattage Reference Guide 19 Your Power Needs 19 Inspection Cleaning and Maintenance 20 Changing Oil 20 Spark Plug 21 Air Filter 21 Spark Arrester optional 22 Cleaning 22 Maintenance Schedule 22 Storage 23 Transporting 23 Troubleshooting 24 Wiring Diagram 25 Parts L...

Page 8: ... electrical power for lighting appliances tools and similar equipment This Booklet Every effort has been made to ensure the accuracy and completeness of the information in this manual We reserve the right to change alter and or improve the product and this document at any time without prior notice For the most up to date information regarding your Smarter Tools product please visit us at usesmarte...

Page 9: ... to the right of the power switch Note The Hour Meter is tied directly to the product warranty Attempting to disable or otherwise tamper with the Hour Meter will VOID the manufacturer s warranty Identification Plate The product s Identification Plate can be found on the lower frame cross arm just behind the air filter See figure below Note Properly registering your product with Smarter Tools is th...

Page 10: ...en normal use has exhausted the life of a part or the equipment as a whole Installation Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical component Normal maintenance such as spar...

Page 11: ...afety instructions Be sure to retain them for future use WARNING WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED CAUTION CAUTIONS INDICATE A POSSIBILITY OF EQUIPMENT DAMAGE IF INSTRUCTIONS ARE NOT FOLLOWED PROPERLY Note Notes give helpful information WARNING IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS IN...

Page 12: ...enclosed area NEVER use a generator inside homes garages crawlspaces or other partially enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These openings can pull in generator exhaust Even when you use a generator correctly ...

Page 13: ...h known leaks in the fuel system Excessive buildup of unburned fuel gases in the exhaust system can create a potentially explosive condition This buildup can occur after repeated failed start attempts valve testing or hot engine shutdown If this occurs open exhaust system drain plugs if equipped and allow the gases to dissipate before attempting to restart the generator Use only engine manufacture...

Page 14: ...utlet reverse the plug If it still does not fit contact a qualified electrician to install a polarized outlet Do not change the plug in any way Double insulation eliminates the need for the three wire grounded power cord and grounded power supply system Before servicing equipment powered by the generator disconnect the equipment from its power input The generator must be earth grounded for fixed i...

Page 15: ...ries or storing the generator Such preventive safety measures reduce the risk of starting the generator accidentally Store idle generators out of reach of children and other untrained persons Generators are dangerous in the hands of untrained users Maintain generators with care Do not use a damaged generator Tag damaged generators Do not use until repaired Check for misalignment or binding of movi...

Page 16: ... should be level and strong enough to safely hold the weight of the generator If the floor grounded surface is not level strong cross members should be placed under the full length of the generator frame at its low side For trailer installation the generator should be mounted on the center point of the trailer over the wheels The trailer must be capable of supporting the weight of the generator an...

Page 17: ...ed For skin contact immediately wash with soap and water For eye contact immediately flush eyes with clean water and seek medical attention Noise Prolonged exposure to noise levels above 85dBA is hazardous to hearing Always wear ANSI approved ear protection when operating or working around the Generator when it is running Extension Cords If an extension cord not included is used make sure to use o...

Page 18: ...RATED ON A LEVEL SERVICE DO NOT OPERATE GENERATOR ON LOOSE GROUND OR OBVIOUS INCLINES THE LOW OIL SHUT DOWN FEATURE MAY BE PREMATURELY ACTIVATED IN THESE CASES CAUSING THE UNIT TO NOT START Make sure to locate and install the generator outdoors where cooling air is readily available Install the generator so that the air inlets and outlets are not blocked by obstructions such as bushes trees or sno...

Page 19: ...nd crutches 6 Install the handles on the right side of the frame using the 2 nuts and 10mm 1 bolts provided WARNING TO AVOID DAMAGE TO THE GENERATOR REMOVE THE BOLT AND SPACER BEFORE USE Support and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator The slab must extend on all sides beyond the frame by at least one foot Contact a cement contractor for...

Page 20: ... with the phillips head cap screw and secure with 8mm nut 4 Remove the protective cover from the negative black battery lead Negative lead is marked with a 5 Attach the negative lead to the negative terminal marked with a on the battery with the phillips head cap screw and secure with 8mm nut 6 The battery will charge when the generator is running with the battery cables attached NOTE Connecting t...

Page 21: ...mix oil with fuel 3 Clean area around the fuel cap 4 Remove the fuel cap 5 Be sure that the fuel strainer is in place 6 Slowly add fuel to the tank DO NOT overfill Allow approximately inch of space for fuel expansion 7 DO NOT fill above fuel strainer 8 Screw on the fuel cap and wipe away and spilled fuel WARNING THE GENERATOR MUST BE OFF AND COOLED DOWN BEFORE REFILLING THE FUEL TANK Note For DEB ...

Page 22: ... least 10 seconds before attempting to start the engine again 7 For Recoil Start hold the start handle loosely and pull it slowly several times to allow the gasoline to flow into the engine s carburetor Then hold the start handle firmly and pull the rope hard and fast Pull the rope all the way out using two hands if necessary If necessary pull the rope several times until the engine starts 1 Allow...

Page 23: ...s They re designed to protect against virtually all short duration voltage fluctuations 2 Obtain an Uninterruptible Power Supply UPS device Most UPS devices come with a rechargeable battery between the electronic equipment and power supply source The device buffers the voltage and protects against virtually all short duration voltage fluctuations Capacity Follow these simple steps to calculate the...

Page 24: ...ads that the unit will power If powering exceeds the generator s capacity it may be necessary to group one or more of the tools and or equipment for connection to a separate generator 3 Once the generator is running verify correct power output and simply connect the power cords of 110 120 volt AC powered tools and equipment into the 110 120 volt AC dual outlets and or the power cord of a 12V DC po...

Page 25: ...ion plate ratings Your Power Needs Tool or Appliance Running Watts Starting Watts 1 2 3 4 5 Total Running Watts Highest Starting Watts Total Running Watts Highest Starting Watts Item Running Watts Starting Watts Essentials Light Bulb 100 100 Refrigerator Freezer 1200 2400 Sump Pump 600 1800 Well Pump 1HP 2000 4000 Water Heater 4000 Security System 180 AM FM Radio 300 Garage Door Opener HP 500 600 ...

Page 26: ...DEFECTIVE GENERATOR Before each use make sure the engine s oil level is at manufacturer s specification If necessary fill the crankcase until the oil level is even with the oil fill hole Make sure there is gas in the unit Before each use remove all debris with a soft brush rag or vacuum Lubricate all moving parts using a premium quality lightweight machine oil CAUTION DO NOT ATTEMPT TO ADJUST MODI...

Page 27: ...hread the plug into the engine 6 Use the spark plug tool to firmly install the plug 7 Attach the spark plug wire to the plug 8 The following spark plugs cross for the Torch F6RTC NGK BPR6ES Champion RN9YC Autolite 63 Bosch WR7DS Denso W20EPR U Air Filter 1 Remove the air filter cover by releasing the snap clips on top and bottom 2 Remove the foam element 3 Wash in liquid detergent and water 4 Sque...

Page 28: ...through the cooling slots and damage the generator windings Maintenance Schedule Follow the service intervals indicated in the schedule below Service your generator more frequently when operating in adverse conditions Every 8 hours of operation or daily Check oil level Clean around air intake and muffler Every 50 hours of operation or every season If operating under heavy load or in hot environmen...

Page 29: ...e the oil and lubricate the cylinder 7 Reinstall the spark plug 8 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help protect it from internal corrosion 9 Clean the generator according to the instructions in the Maintenance section 10 Sto...

Page 30: ...erator on a flat level surface before starting Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected device is defective Replace defective device Circuit breaker is open Reset ci...

Page 31: ...DC WINDING DC TERMINAL CIRCUIT PROTECTOR CIRCUIT PROTECTOR CIRCUIT PROTECTOR 20A 30A 8A STGP 4750EB WIR 1 DIAGRAM ...

Page 32: ...ING 2 11 QJ166QDK 01 07 DRAIN PLUG GASKET 2 12 QJ166QDK 01 06 DRAIN PLUG 2 13 JF170FLH 01 01B CRANKCASE ASSEMBLY 1 14 157 4 6 DOWEL PIN 2 No Part No Description Qty 1 QJ166QDK 03 11 AJDUSTING NUT 2 2 QJ182QDP 03 07 BUTTONHEAD 2 3 QJ168QDJ 03 09 ROCKER ARM 2 4 QJ168QDJ 03 02 ROTATOR CAP 1 5 QJ168QDJ 03 10 UPPER RETAINER EXHAUST 1 6 QJ168QDJ 03 07 VALVE SPRING 2 7 QJ167QDJ 03 05 EXHAUST VALVE 1 8 QJ...

Page 33: ... ROD TUBE 1 7 QJ168QDJ 02 01 04 VALVE STEM SEAL 1 8 GB T6177 NUT M6 2 9 QJ168FJH 3 02 01 INTAKE STUD 2 10 QJ168QDJ 02 05 INTAKE GASKET CARBUREATOR 1 11 QJ168QDJ 02 02 Intake manifold 1 12 QJ168QDJ 02 04 INTAKE GASKET MANIFOLD 1 13 QJ168QDL 02 01 01 CYLINDER HEAD BARE 1 14 QJ168QDJ 02 06 VALVE COVER GASKET 1 15 QJ168QDJ 02 03 VALVE COVER 1 16 GB T5789 BOLT M6 X 14 VALVE COVE BOLTS 4 17 QJ1E50FMG 1 ...

Page 34: ...1 STATOR ASSEMBLY 120V 1 17 GB T271 87 BALL BEARING 6202Z 1 18 GB T5789 86 BOLT M8 230 1 19 QJ3200 03 02 ROTOR ASSEMBLY 1 20 QJ2500 03 02 01 IMPELLER 1 No Part No Description Qty 1 QJ168QDJ 04 06 FLYWHEEL NUT 1 2 QJ168QDJ 04 10 RATCHET WHEEL STARTER CUP 1 3 QJ168QDJ 04 11 FAN 1 4 JF168FJH 5 02 01 FLYWHEEL 1 5 QJ182QDP 04 03 KEY 1 6 QJ168QDJ 04 09 DRIVE GEAR 1 7 QJ168QDL 2 01 01B CRANKSHAFT 1 8 QJ1...

Page 35: ...6177 1 2000 FLANGE NUT M5 2 15 GB T5789 86 BOLT M5 12 2 No Part No Description Qty 1 GB T5789 1986 BOLT M6 X 8 3 2 JF168FLH 3 06 01D STARTER COVER ASSEMBLY 1 2 1 JF168FLH M 06 01 01 STARTER COVER 1 2 2 JF168FLH M 06 01 02 SPIRAL SPRING TURBINATION 1 2 3 JF168FLH M 06 01 03 REWIND PULLY ROTARY TABLE 1 2 4 JF168FLH 3M 06 01 04 WASHER 1 2 5 JF168FLH 3M 06 01 05 PRESS REED 1 2 6 JF168FLH 3M 06 01 06 R...

Page 36: ...05 06 TENSION SPRING 2 1 4 GB T6177 NUT M6 1 5 QJ182QDP 06 03 SQUARE BOLT 1 6 QJ168QDJ 05 06 SPACER 2 1 7 QJ182QDP 06 02 CIRCLIP 1 8 QJ168QDJ 05 03 FORK 1 9 QJ166QDK 06 03 SPACER 1 1 10 QJ168QDJ 05 04 PIN 1 11 QJ166QDK 01 02 HAIRPIN COTTER PIN 1 12 QJ168QDJ 05 02 01 CENTRIFUGAL ADJUSTMENT 1 13 QJ168QDJ 05 02 03 CENTRIFUGAL BLOCK 2 14 QJ168QDJ 05 02 02 PIN 2 15 QJ168QDJ 05 08 SPACER 3 1 16 QJ168QDJ...

Page 37: ... BELLOW HULL ASSY 1 1 5 QJ168FJH 3 05 01 03 SUSTAIN BOARD 1 1 6 GB T9074 11 BOLT M5 X 14 4 2 QJ168FJH 3 05 01 BREATHER TUBE 1 3 QJ168QDJ 07 03 AIR CLEANER GASKET 1 4 GB T5789 BOLT M6 X 10 1 5 QJ168FJH 3 05 02 AIR CLEANER BRACKET 1 No Part No Description Qty 1 GB T819 2 1997 SCREW M5 X 10 2 2 QJ6000 01 03 FUEL GUAGE 1 3 QJ6000 01 04 GAS CAP 1 4 QJ950 13 02 FILTER SCREEN 1 5 KE3500 01 01A FUEL TANK ...

Page 38: ...M SHELL 1 2 GB T818 2000 SCREW M6 X 16 4 3 QJ6500B 01 02 IGNITION SWITCH 1 4 KE9000E 02 05 MULTI PURPOSE DIGITAL METER 1 5 GB T6177 1 2000 NUT M4 8 6 QJ3500 02 03A 30 BREAKER 1 7 QJ6500 02 08 8A BREAKER 1 8 KE4500E 02 03B RV OUTLET 1 9 QJ6500D 01 05 3 POLE TWISTLOCK OUTLET 1 10 QJ3200 01 04 STANDARD OUTLET 1 11 KE4500E 02 01B PANEL FACEPLATE 1 12 GB T845 1985 SCREW ST 4 X 16 8 13 QJ2600 02 03 LOW ...

Page 39: ...UNTING TAB PART OF FRAME 4 3 GB T5789 1986 BOLT M6 X 10 2 4 KE3500 04 03A TANK PROTECTOR PLATE 2 5 PR8800DXE 04 02 AXLE BOLT M12 X 65 2 6 QJ3780 04 05A 7 WHEELS 2 7 GB T95 2002 WASHER 13 2 8 QJ2600 08 02 ENGINE SHOCK MOUNTS 2 9 GB T6177 1 2000 NUT M8 8 10 QJ2500 06 03 GENSET SHOCK MOUNTS 2 11 KE3500 04 04 CRUTCH 2 12 QJ3200TB 02 01 CRUTCH PLUG 2 13 QJ6800 06 01 CRUTCH BOOT 2 14 GB T5789 1986 BOLT ...

Page 40: ...GP Series 34 2013 Smarter Tools Inc All Rights Reserved English __________ Español ...

Page 41: ...El generador está sobrecargado Revise la carga y ajustar Consulte la sección Administración de energía ventilación insuficiente Compruebe si hay restricción de aire Vaya a un área bien ventilada No hay salida de CA Cable no está conectado correctamente Compruebe todas las conexiones El dispositivo conectado está defectuoso Reemplace el dispositivo defectuoso El interruptor automático está abierto ...

Page 42: ... para distribuir el aceite y lubricar el cilindro 7 Vuelva a instalar la bujía 8 Tire lentamente del mango de arranque hasta que sienta resistencia En este punto el pistón está subiendo en su carrera de compresión y tanto la válvulas de admisión y escape están cerradas Almacenar el motor en esta posición ayudará a protegerlo de la corrosión interna 9 Limpiar el generador de acuerdo con las instruc...

Page 43: ...devanados del generador Programa de mantenimiento Siga los intervalos de servicio indicados en la siguiente tabla Servicio al generador con más frecuencia cuando se opera en condiciones adversas Cada 8 horas de funcionamiento o diariamente Revise el nivel de aceite Limpie el área de admisión de aire y el silenciador Cada 50 horas de funcionamiento o cada estación Si se opera bajo carga pesada o en...

Page 44: ...uidado el enchufe en el motor 6 Utilice la herramienta para bujías para instalar firmemente el enchufe 7 Conecte el cable de la bujía a la bujía 8 La chispa se conecta siguiente cruz por la Antorcha F6RTC NGK BPR6ES Champion RN9YC Autolite 63 Bosch WR7DS Denso W20EPR U Filtro de aire 1 Retire la tapa del filtro de aire por la liberación de los clips de resorte en la parte superior e inferior 2 Ret...

Page 45: ...el nivel de aceite del motor está en la especificación del fabricante Si es necesario llene el cárter hasta el nivel de aceite es uniforme con el orificio de llenado de aceite Asegúrese de que haya gas en la unidad Antes de cada uso retire todos los restos con un cepillo suave un trapo o una aspiradora Lubrique todas las piezas móviles con una calidad premium aceite de máquina liviano PRECAUCIÓN N...

Page 46: ...cación Sus necesidades de energía Herramienta o Aparato Eléctrico vatios de funcionamiento A partir Watts 1 2 3 4 5 Total de vatios de funcionamiento Máximas vatios de arranque Total de vatios de funcionamiento Máximas Watts partir Item Running Watts Starting Watts Essentials Bombilla 100 100 Nevera Congelador 1200 2400 Sump Pump 600 1800 Bombas para pozos 1HP 2000 4000 calentador de agua 4000 sis...

Page 47: ...dad de alimentación del generador puede ser necesario al grupo de una o más de las herramientas y o equipos para conexión a un generador independiente 3 Una vez que el generador está en funcionamiento verificar la potencia de salida correcto y simplemente conectar los cables de alimentación de 110 120 voltios herramientas alimentadas por CA y equipos a las tomas de corriente alterna 110 120 voltio...

Page 48: ... proteger contra casi todas las fluctuaciones de tensión de corta duración 2 Obtener un Sistema de alimentación ininterrumpida UPS La mayoría de los dispositivos UPS vienen con una batería recargable entre el equipo electrónico y la fuente de alimentación El dispositivo regula el voltaje y protege contra casi todas las fluctuaciones de tensión de corta duración Capacidad Siga estos pasos sencillos...

Page 49: ...intentar arrancar el motor de nuevo 7 Por Inicio Recoil mantenga el mango inicio libremente y tire de ella lentamente varias veces para permitir que la gasolina fluya hacia el carburador del motor Sostenga el asa inicio firmemente y tire de la cuerda fuerte y rápido Tire de la cuerda hasta el tope utilizando las dos manos si es necesario Si es necesario tirar de la cuerda varias veces hasta que el...

Page 50: ...e combustible 4 Retire la tapa del combustible 5 Asegúrese de que el filtro de combustible está en su lugar 6 Poco a poco agregue combustible al tanque NO llene excesivamente Deje aproximadamente de pulgada de espacio para la expansión del combustible 7 NO llene por encima de filtro de combustible 8 Atornille la tapa del combustible y limpie el combustible derramado y 9 ADVERTENCIA El generador de...

Page 51: ...o de cabeza Phillips y asegure con la tuerca de 8 mm 4 Retire la cubierta protectora del cable negativo negro Cable negativo está marcado con un signo 5 Conecte el cable negativo al terminal negativo marcado con un signo en la batería con el tornillo de cabeza Phillips y asegure con la tuerca de 8 mm 6 La batería se carga cuando el generador está funcionando con los cables de la batería conectados...

Page 52: ...tale las manijas en el lado derecho del marco con las tuercas 2 y 10 mm de 1 tornillos proporcionados ADVERTENCIA PARA EVITAR DAÑOS AL GENERADOR RETIRE EL TORNILLO Y EL SEPARADOR ANTES DE USAR Apoyo y Montaje Montar el generador en una losa de hormigón capaz de soportar el peso del generador La losa debe extenderse por todos los lados más allá del bastidor por lo menos un pie Póngase en contacto c...

Page 53: ... NO OPERE EL GENERADOR POR TERRENO BLANDO O PENDIENTES OBVIO EL ACEITE BAJO FUNCIÓN DE APAGADO PUEDE SER ANTES DE TIEMPO ACTIVO EN ESTOS CASOS QUE CAUSAN LA UNIDAD NO EMPEZAR Asegúrese de colocar e instalar el generador en exteriores donde el aire de enfriamiento es fácilmente disponible Instale el generador de manera que las entradas y salidas de aire no estén bloqueadas por obstáculos tales como...

Page 54: ...or contacto con la piel lavar inmediatamente con agua y jabón En caso de contacto lave inmediatamente los ojos con agua limpia y busque atención médica Ruido La exposición prolongada a niveles de ruido superiores a 85 dBA es peligroso para la audición Use siempre protección aprobada para el oído ANSI al operar o trabajar cerca del generador cuando se está ejecutando Cables de extensión Si utiliza ...

Page 55: ...plana y lo suficientemente fuerte como para sostener con seguridad el peso del generador Si la superficie del suelo tierra no está a nivel los miembros transversales fuertes se debe colocar debajo de toda la longitud de la carcasa del generador en su lado de baja Para la instalación de remolque el generador debe ser montado en el punto central del remolque sobre las ruedas El remolque debe ser cap...

Page 56: ... el generador Estas medidas de seguridad preventivas reducen el riesgo de encender el generador de forma accidental Guarde los generadores estén usando fuera del alcance de los niños y otras personas no capacitadas Los generadores son peligrosas en manos de personas inexpertas Mantenga los generadores con cuidado No use un generador dañado Generadores de etiquetas dañadas No usar hasta que sea rep...

Page 57: ...o entra completamente en el tomacorriente invierta el enchufe Si aún así no encaja comuníquese con un electricista calificado para que instale un tomacorriente polarizado No cambie el enchufe de ninguna manera El doble aislamiento elimina la necesidad de que el sistema trifilar conectado a tierra cable de alimentación conectado a tierra y la fuente de alimentación Antes de dar servicio al equipo a...

Page 58: ...sistema de combustible La acumulación excesiva de los gases sin quemar de combustible en el sistema de escape puede crear una condición potencialmente explosiva Esta acumulación puede ocurrir después de repetidos intentos fallidos de inicio la prueba de la válvula o parada del motor caliente Si esto ocurre drenaje abierto se conecta el sistema de escape si está equipado y permitir que los gases qu...

Page 59: ...as casas garajes sótanos u otras áreas parcialmente cerradas Niveles mortales de monóxido de carbono puede acumularse en estas áreas El uso de un ventilador o abrir las ventanas y las puertas no suministra suficiente aire fresco SÓLO utilice el generador al aire libre y lejos de ventanas puertas y conductos de ventilación Estas aberturas pueden atraer el escape del generador Incluso cuando se util...

Page 60: ... Asegúrese de conservar para uso futuro ADVERTENCIA ADVERTENCIAS INDICAN UNA CERTEZA O FUERTE POSIBILIDAD DE LESIONES PERSONALES O MUERTE SI NO SE SIGUEN LAS INSTRUCCIONES PRECAUCIÓN PRECAUCIONES INDICAR UNA POSIBILIDAD DE DAÑOS EN EL EQUIPO SI LAS INSTRUCCIONES NO SE SIGUEN CORRECTAMENTE Nota Las notas proporcionan información útil ADVERTENCIA FUNCIONAMIENTO INADECUADO O MANTENIMIENTO DE ESTE PRO...

Page 61: ...o Esta garantía no se aplica a las piezas y o mano de obra si este generador se considera que ha sido utilizada indebidamente descuidado involucrado en un accidente abuso cargado más allá de los límites del generador modificados o instalados incorrectamente conectado incorrectamente a algún componente eléctrico El mantenimiento normal tales como bujías filtros de aire ajustes limpieza del sistema ...

Page 62: ...tor de encendido Nota El cronómetro está ligado directamente a la garantía del producto El intento de desactivar o manipular el contador horario anulará la garantía del fabricante Placa de identificación Placa de identificación del producto se puede encontrar en el brazo transversal inferior del marco justo detrás del filtro de aire Consulte la figura a continuación Nota Correctamente registrar su...

Page 63: ...al power for lighting appliances tools and similar equipment Este Folleto Cada esfuerzo se ha hecho para asegurar la exactitud e integridad de la información contenida en este manual Nos reservamos el derecho de cambiar alterar y o mejorar el producto y este documento en cualquier momento sin previo aviso Para la más actualizada información sobre su producto más inteligente Herramientas visítenos ...

Page 64: ... combustible S15 Operación S16 Comienzo S16 Protección contra sobretensiones S17 Capacidad S17 Gestión de energía S18 Conexión de las cargas eléctricas S18 Parada del motor S18 Administración de energía S19 Sus necesidades de energía S19 Inspección limpieza y mantenimiento S20 Cambio de aceite S20 Bujía S21 Filtro de aire S21 Chispa Arrestor opcional no se puede acceder en unidades más grandes S22...

Page 65: ...akers Protects the generator against electrical overload 4 120V 20A Duplex This duplex is protected by a 20A circuit breaker Use this duplex to operate 120 volt AC single phase 60 Hz loads requiring up to 20 A or 2400 Watts of power 5 120V 30A Twist Lock This receptacle powers 120 Volt AC 60 Hz single phase loads requiring up to 30A or 3600 Watts of power 6 120V 30A RV Outlet This receptacle power...

Page 66: ...or 1 Fuel Gauge Indicates amount of fuel in tank 2 Fuel Tank 4 gallon capacity 3 Choke Used to start engine 4 Fuel Valve Turn this valve to the on position to supply fuel to the engine 5 Air Filter Protects the engine by filtering dust and debris from the intake air 6 Recoil Starter Used to start the engine 7 Low Oil Shutdown Senses the level of oil in the crankcase and shuts the engine down if th...

Page 67: ...tarting Watts 4750w Rated Frequency 60HZ Rated Voltage 120V Rated Current 30A Run Time 10hrs at 50 load Receptacles qty 2 120V AC 20A 1 120V 30A RV 1 120V 30A AC 1 12V 8A DC Net Gross Weight 92 105lbs Noise Level dB 72dB Fuel Type Unleaded gasoline Fuel Capacity gal 4 Fuel Gauge Yes Oil Type SAE 10W 30 20 oz 62 Qt Start Type Electric Recoil AC Volt Meter Yes Frame Construction Tubular Steel Wheel ...

Page 68: ...___________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ __...

Page 69: ...omo la fecha y lugar de compra para referencia futura Tenga esta información a mano cuando solicite partes y al hacer consultas técnicas o garantía Más inteligente Herramientas de Servicio al Cliente 1 888 241 8498 Número de modelo GP4750 E EB Número de Serie Fecha de compra Compra Vivo ...

Page 70: ... de instrucciones ST GP4750 ADVERTENCIA Para reducir el riesgo de lesiones el usuario debe leer y comprender el manual del propietario antes de usar NOTA Guarde recibo de compra original como prueba de compra ...

Reviews: