background image

Longo programmable controller LPC-2.PW1

STANDARDS   AND   PROVISIONS:   Standards,   recommendations,
regulations  and provisions  of  the  country  in  which  the  devices  will
operate, must be considered while planning and setting up electrical
devices. Work on  100 .. 240 V AC  network is allowed for authorized
personnel only.

DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from
moisture, dirt and damage during transport, storing and operation.

WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no
modifications   are   performed   upon   and   are   correctly   connected   by
authorized   personnel   –   in   consideration   of   maximum   allowed
connecting power, warranty of 24 months is valid from the date of
sale to the end buyer, but not more than 36 months after delivery
from Smarteh. In case of claims within warranty time, which are based
on material malfunctions the producer offers free replacement. The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not   include   damage   due   to   transport   or   because   of   unconsidered
corresponding   regulations   of   the   country,   where   the   module   is
installed.
This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous  voltage  in  the  device  can  cause  electric  shock  and  may
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).

If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected
separately!

LONGO LPC-2 complies to the following standards:

EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-
3-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013

LVD: IEC 61010-1:2010 (3

rd

 Ed.), IEC 61010-2-201:2013 (1

st

 Ed.)

Smarteh   d.o.o.   operates   a   policy   of   continuous   development.
Therefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia

ii

Summary of Contents for LPC-2.PW1

Page 1: ...ER MANUAL Longo programmable controller LPC 2 PW1 4 Channel PWM Signal Output module Version 2 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh s...

Page 2: ...Longo programmable controller LPC 2 PW1 Written by SMARTEH d o o Copyright 2018 SMARTEH d o o User Manual Document Version 2 January 2018 i...

Page 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...

Page 4: ...IATIONS 1 2 DESCRIPTION 2 3 FEATURES 3 4 OPERATION 4 4 1 Parameters 4 4 2 Output waveform for output setting 0 and 100 5 5 INSTALLATION 6 5 1 Connection scheme 6 5 2 Mounting instructions 8 5 3 Module...

Page 5: ...Longo programmable controller LPC 2 PW1 1 ABBREVIATIONS LED Light emitting diode PWM Pulse width modulation 1...

Page 6: ...n field of application is controlling PWM dimmable ballasts in lighting system LEDs indicate state of signal present on corresponding module output Their brightness corresponds to the output setting 0...

Page 7: ...signal output Galvanic isolated outputs 100 mA per output with overload protection Push pull transistor outputs capable of driving the signal over up to 100 nF capacitance on the lines Adjustable tran...

Page 8: ...a 0 10000 0 00 100 00 Q3 PWM output OUT3 Output setting Type WORD Raw to engineering data 0 10000 0 00 100 00 Q4 PWM output OUT4 Output setting Type WORD Raw to engineering data 0 10000 0 00 100 00 Se...

Page 9: ...Longo programmable controller LPC 2 PW1 4 2 Output waveform for output setting 0 and 100 Figure 2 Output waveform for output setting 0 and 100 5...

Page 10: ...Longo programmable controller LPC 2 PW1 5 INSTALLATION 5 1 Connection scheme Figure 3 Connection scheme1 1 Outputs must not be connected together 6...

Page 11: ...ply Connection to I O module Table 4 K2 Internal BUS Data DC power supply Connection to I O module Table 5 LEDs LED1 green Q1 output state ON gradually Q1 output 0 OFF Q1 output on 0 LED2 green Q2 out...

Page 12: ...ount each module to the DIN rail first then attach modules together through K1 and K2 connectors 4 Connect digital inputs and outputs wires according to the connection scheme in Figure 2 5 Switch on m...

Page 13: ...Longo programmable controller LPC 2 PW1 Figure 5 Minimum clearances The clearances above must be considered before module mounting 9...

Page 14: ...1 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 17 01 is the date code 17 week and 01 year of production Label 2 description 1 S N PW1 S9 1700000002 is the...

Page 15: ...resolution 1 us Output jitter 500 ns Pulse width accuracy of the full scale value 2 Load capacitance max 100 nF Fuse no Connection type screw type connectors for stranded wire 0 75 to 2 5 mm2 Dimensi...

Page 16: ...Longo programmable controller LPC 2 PW1 7 SPARE PARTS For ordering spare parts following Part Numbers should be used LPC 2 PW1 4 Channel PWM Signal Output module LPC 2 PW1 P N 225PW117001001 12...

Page 17: ...ontroller LPC 2 PW1 8 CHANGES The following table describes all the changes to the document Date V Description 15 01 18 2 Technical update Page 7 11 15 11 17 1 The initial version issued as LPC 2 PW1...

Page 18: ...Longo programmable controller LPC 2 PW1 9 NOTES 14...