3. Stop-Down at Drive Section
If – no response at activation on regulating lever
(no click sound)
Check whether main switch is on - to be turned clockwise to switch on. Has the red On/Off switch on the
regulating lever been put into position On (green lamp on)? Have batteries been charged (check indicator)?
Is the 80-ampere fuse beside the motor control under the screen at the front of the machine OK?
Check regulating lever and cables for visible faults and damage. There may be faults on lever or control
unit.
Control light on switch may show error code at various flash signals (contact Smartlift)
47 a - ON/OFF switch
Fast and slow function
47 b - Fuse 80 A for drive
48 -Accelerator DRIVE,
Forward and back
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk
If the yoke has been dismantled, be
aware that the washer is placed
between the castle nut and the
yoke.