US SL 580 MAXI 03/2016
24
Syncronous controller (controller for lifting actuators)
Controller for lifting actuators (2
pcs.)
Voltage between clamps 1 and 2
must be approx. 24 Volt
Safety switch below the lifting
actuators can be switched off.
Voltage between clamp 1 and 13
must be approx. 24 Volt
Press up and down on the remote
control. Voltage between clamp 1
and 9 and 1 and 10 must be
approx. 24 Volt
Possible faults on pulses from
lifting actuator can be checked by
activating the control panel in
steps. At the same time measure
the voltage between clamps 1 and
7 as between 1 and 8 for actuator
1.
For actuator 2 between clamps 1
and 11 as between 1 and 12
The measuring device varies from
0-24 VOLT
Clamp 1 and 13
Clamp 1 and 16
Clamp 1 and 10
Clamp 1 and 9
Aktuator 1, Clamp 1 and 7 + 1 and 8
Aktuator 2, Clamp 1 and 11 + 1 and 12
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk