8.21 Adopting a Configuration from a File
Requirements:
☐ Changes to grid-relevant parameters must be approved by the responsible grid operator.
☐ The SMA Grid Guard code must be available (see "Application for SMA Grid Guard Code"
Procedure:
1. Activate the user interface (see Section 8.1, page 64).
2. Log into the user interface as an
Installer
.
3. Select the menu
Device Configuration
.
4. Select [
Settings
].
5. In the context menu, select [
Adopting the configuration from a file
].
6. Follow the instructions in the dialog.
8.22 Updating the Firmware
If no automatic update is set for the inverter in the communication product (e.g.
SMA Data Manager, Cluster Controller, Sunny Portal) or via the user interface of the inverter, you
have the option of carrying out a manual firmware update.
Depending on the battery used, the firmware update of the inverter also updates the battery.
You have the following options to update the firmware:
• Update the firmware with the existing update file via the user interface of the inverter.
• Update the firmware with the existing update file via USB flash drive.
• Search and install the firmware via the user interface of the inverter.
Faulty firmware update due to disconnecting the inverter from the utility
grid.
The inverter must be connected to the utility grid during the firmware update. The battery-
backup and secure power-supply operation mode must be disabled. This ensures a proper
firmware update.
• Do not disconnect the inverter from the utility grid during the firmware update.
• Do not enable secure power supply operation during the firmware update.
• Do not use the black-start button during the firmware update.