SMA
Technologie AG
Technical Data
Installation Guide
SB25_30-11:SE0307
Page 47
8.4.3 Country-specific Parameter Settings
The parameters listed below represent country-specific settings and are only displayed
in installer mode. All other parameters are international and can be viewed in the table
in section 8.4.2 "Parameter Settings for Germany" (Page 45).
Sunny Boy SB 2500
Sunny Boy SB 3000
Name
Short
descr.
Country settings
Germany
Great Britain
Spain
Default
GER/VDE0126-1-1 GB/G83
SP/RD1663
dFac-Max
Hz/s
4
0.2
2
dZac-Max
mOhm
700
350
350
Fac-delta-
Hz
2.45
0.5
0.98
Fac-delta+
Hz
0.19
0.5
0.98
I-NiTest
mA
8000
0
0
T-Start
s
10
180
10
Uac-Min
V
198
209
199
Uac-Max
V
260
261
250
Name
Short
descr.
Country settings
Germany
Great Britain
Spain
Default
GER/VDE0126-1-1 GB/G83
SP/RD1663
dFac-Max
Hz/s
0.25
0.2
2
dZac-Max
mOhm
700
350
350
Fac-delta-
Hz
2.45
0.5
0.98
Fac-delta+
Hz
0.19
0.5
0.98
I-NiTest
mA
9000
0
0
T-Start
s
10
180
10
Uac-Min
V
198
209
199
Uac-Max
V
260
261
250
Summary of Contents for Sunny Boy SB 2500
Page 2: ......
Page 6: ...Explanation of the Symbols Used SMA Technologie AG Page 6 SB25_30 11 SE0307 Installation Guide...
Page 10: ...Safety Instructions SMA Technologie AG Page 10 SB25_30 11 SE0307 Installation Guide...
Page 20: ...Installation Requirements SMA Technologie AG Page 20 SB25_30 11 SE0307 Installation Guide...
Page 62: ...The Communication Interface SMA Technologie AG Page 62 SB25_30 11 SE0307 Installation Guide...
Page 65: ......