Displays and Messages
7-4
SMA America
SB6000U-13:SE2506
Starting
The inverter has sufficient PV power to calibrate its internal systems, but not enough to
begin normal operation. Typically, the calibration lasts less than 10 seconds and then
the inverter resumes normal operation. PV voltage must remain > PV Start Voltage
setting for the period of the P-Start parameter setting. (See Section 8) The inverter will
also show this status if it has been manually set to STOP mode.
Waiting
The inverter has determined that there is enough voltage from the array to operate and
is checking the condition of the grid prior to connecting to it.
Note:
If the inverter fails to connect to the utility grid 3 times
in a row, it will wait 10 minutes before the next attempt.
In case of a grid failure, the Sunny Boy waits 5 minutes
before it tries to reconnect to the grid.
http://www.wholesalesolar.com/inverters.html
http://www.wholesalesolar.com/inverters.html