13 Technical Data
SMA Solar Technology AG
Operating manual
SBxx-1AV-41-BE-en-12
103
SB5.0-1AV-41
SB6.0-1AV-41
Maximum short-circuit current,
input B*
20 A
20 A
Maximum reverse current into
the PV array
0 A
0 A
Number of independent MPP
inputs
2
2
Strings per MPP input
2
2
Surge category in accordance
with IEC 60664-1
II
II
* In accordance with IEC 62109-2: ISC PV
AC Output
SB5.0-1AV-41
SB6.0-1AV-41
Rated power at 230 V, 50 Hz*
5000 W
6000 W
Maximum apparent AC power at cos φ = 1**
5000 VA
6000 VA
Rated grid voltage
230 V
230 V
Nominal AC voltage
220 V / 230 V / 240
V
220 V / 230 V / 240
V
AC voltage range***
180 V to 280 V
180 V to 280 V
Nominal AC current at 220 V
22.8 A
26.1 A
Nominal AC current at 230 V
22 A
26.1 A
Nominal AC current at 240 V
21 A
25 A
Maximum output current****
22.8 A
26.1 A
Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
<2%, and AC power >50% of the rated power
≤3 %
≤3 %
Maximum output current under fault conditions
29 A
29 A
Inrush current
< 20% of the nominal
AC current for a
maximum of 10 ms
< 20% of the nominal
AC current for a
maximum of 10 ms
Rated power frequency
50 Hz
50 Hz
AC power frequency***
50 Hz / 60 Hz
50 Hz / 60 Hz
Operating range at AC power frequency 50 Hz
45 Hz to 55 Hz
45 Hz to 55 Hz
Operating range at AC power frequency 60 Hz
55 Hz to 65 Hz
55 Hz to 65 Hz
Power factor at rated power
1
1