6 Mounting
SMA Solar Technology AG
Installation Manual
SCCP-JP_NR-IA-en-11
20
Mounting the cover of the silencing baffle
Required mounting material:
☐ 1 cylindrical screw
☐ 3 contact washers
☐ 9 pan head flange screws
☐ 13 washers
☐ 10 hexagon nuts
Procedure:
1. Align the lid on the rear panel. Place the cover over the stud bolts.
2. Insert a cylindrical screw with contact washer into the top left
thread. Do not tighten the screw yet.
3. Screw five pan head flange screws into the upper threads on the
cover. Do not tighten the screws yet.
4. Fasten the ventilation plate of the rear panel of the silencing baffle
to the cover. Do not yet tighten the four pan head flange screws
yet.
5. Screw two hexagon nuts with contact washers onto the bottom
right and left stud bolts on the rear panel.