7 Settings using the Rotary Switches
SMA Solar Technology AG
58
STP5-9TL-IA-en-10
Installation Manual
Figure 18: Positions of rotary switch C
1. Disconnect the inverter from voltage sources (see Section 10).
2. Determine a free NetID using the Sunny Explorer software (see documentation of the
Sunny Explorer software).
3. To configure a new NetID, set the rotary switch
C
to
the determined NetID using a slotted screwdriver
(blade width: 2.5 mm).
4. To deactivate the communication via
Bluetooth
, set
the rotary switch
C
to the position
0
using a slotted
screwdriver (blade width: 2.5 mm). This protects
your plant from unauthorised access.
5. Recommission the inverter (see Section 8).
☑ The inverter will adopt the setting after commissioning. This can take up to five minutes.
Position
Explanation
0
Communication via
Bluetooth
is deactivated.
1
Communication via
Bluetooth
with one communication product.
2 … F
NetID for communication with other inverters and several communication
products via
Bluetooth
.