SMA Solar Technology AG
7 Settings using the Rotary Switches
Installation Manual
STP5-9TL-IA-en-10
55
7.2 Changing the Country Data Set and the Display Language
By default, the inverter is set to a specific country data set. You will find the country data set to which
the inverter has been configured on the type label and the enclosed supplementary sheet with the
default settings. If the country data set of the inverter does not apply to your country, you must change
the country data set and the display language. You can change this via two rotary switches before
commissioning. You can also change the display language independently of the country data set
(see Section 7.3). If the inverter is in operation, you can change the country data set by means of a
communication product (see Section 9.4).
1. Disconnect the inverter from voltage sources (see Section 10).
2. Set the rotary switches
A
and
B
to the desired
position using a slotted screwdriver (blade width:
2.5 mm) (see Section 7.1 "Overview of the Rotary
Switches", page 52).
3. Recommission the inverter (see Section 8).
☑ The inverter will adopt the setting after commissioning. This can take up to five minutes.