Event number
Message, cause and corrective measures
10286
WLAN connection lost
The inverter has lost WLAN connection to the selected network.
Corrective measures:
• Ensure that the WLAN router or WLAN Access Point is still active.
• Ensure that the WLAN router or WLAN Access Point is in range and is
signalizing correct operation.
• If this message is displayed often, improve the WLAN connection by
using a WLAN repeater.
10339
Webconnect enabled
The Webconnect function has been activated.
10340
Webconnect disabled
The Webconnect function has been deactivated.
10341
Webconnect error: no connection
No connection to Sunny Portal possible.
Corrective measures:
• Ensure that the Internet connection is working properly.
• Ensure that the Webconnect function is activated.
• Ensure that the network cable at the inverter is correctly connected.
10343
Webconnect error: Default gateway not configured
The standard gateway was not configured.
Corrective measures:
• Configure the standard gateway.
10344
Webconnect error: DNS server not configured
DNS server was not configured.
Corrective measures:
• Configure DNS server.
10345
Webconnect error: No reply to DNS request |xx|
DNS server not available
Corrective measures:
• Ensure that the address of the DNS server has been entered correctly.
• Ensure that the network cable at the inverter is correctly connected.