PURBROOK INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
13. Wiring diagrams
Note: All systems are supplied with a 12 core cable. Note: the functions fitted within the lock
are dependent on the enhancements specified. Wires should be tinned.
Surface mounted cable routing:
Remove cable cover plate
and drill 7mm hole as shown.
Ensure no sharp edges
Cable route through door:
Maximum voltage through monitoring switches = 50V
Maximum current through monitoring switches = 500mA
Maximum solenoid voltage/current:
12V systems = 14V max, use 2.5A fuse
24V systems = 28V max, use 2.5A fuse
/ current through solenoid = See table below
Note: Use fuse or current limiter to ensure current limits are not
exceeded