background image

©2011 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM

USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON  N1T 1J6 

PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: [email protected] 

I N S T A L L A T I O N

8310-IQ/8320-IQ

8330-IQ/8340-IQ

IntelliMag

®

Electromagnetic Locks

Pre-Installation Instructions

1.

This product must be installed according to all applicable
building and life safety codes. 

2.

Due to the variety of mounting configurations available with
this product, a survey and assessment of the physical area
in which the product will be installed must be performed. 

3.

The door frame must be inspected and deemed structurally
sound prior to installation of the electromagnetic lock. The
structural integrity of the mounting surfaces must be strong
enough to meet or exceed the holding force of the product. 

4.

The product must be protected from potential damage due
to intruders or tampering. 

5.

The product should be installed in a location that will not
hinder or create a potential safety hazard to authorized
personnel accessing the protected area. 

6.

Because electromagnetic locks are used in a variety of
applications and different door frame configurations, an
experienced installer with knowledge of this product must
make a determination of the optimal mounting method for
this specific application. 

7.

The components, hardware, installation instructions and
mounting template included with this product are intended
for use on outswinging doors. 

8.

Do not install this product on the exterior of buildings. 

9.

Do not use as a doorstop. This will void warranty.

10

. Separate accessories not included with this product must be

used in the following applications: 

• Inswinging doors 
• Narrow head jamb situations or center-hung doors 
• Wherever there is insufficient space on the door frame

header to mount the lock

• Glass or Herculite doors that do not have a door frame 
• Hollow metal or wood frames where the door stop is

not thick enough to allow the product to be installed 

• Wherever an obstruction in the door prevents 

installation of the armature plate at a proper height 

• Doors that do not permit the armature plate to be 

mounted low enough to meet the magnet surface 

Refer to the Product Accessories Guide section of the
Installation Instructions for further information. 

11.

Installation of this product should be done by an

experienced installer with knowledge of this product. 

NOTE:

It is highly recommended that thread locking compound

be applied to all screws during installation to reduce chance of
screws loosening over extended time.

®

IS8310-IQ

PCN110045

R07/11SH

1.

Mount the electromagnetic lock to the door frame as outlined
on the installation template included with the product. 

NOTE:

During installation of the armature plate to the door it is

essential that the armature plate remains movable. The armature
plate must be allowed to pivot on the center-mounting bolt to
allow proper alignment with the magnet surface. If the plate is
not aligned with the magnet surface, the lock may lose holding
force or not lock at all. 

The head of the armature mounting bolt ships with a rubber

washer affixed to it. This washer should project slightly beyond
the surface of the armature plate. This is to allow the washer to
expand when power is removed and break the air vacuum
between the plate and the magnet surface. If this washer is
removed or trimmed the lock will appear to have some holding
force even when power is removed.

For added safety, thread locking compound has been provided for

the armature plate bolt and the four captive electromagnetic lock
mounting screws.

WARNING: Improper installation, maintenance, inspection or

usage of the product or any related accessories or parts may cause
the electromagnetic lock, armature plate and associated hardware
to disengage and fall, causing serious bodily injury and property
damage. Rutherford Controls Int'l Corp. will not be liable to the
installer, purchaser, end user or anyone else for damage or injury
to person or property due to improper installation, care, storage,
handling, maintenance, inspection, abuse, misuse or act of God or
nature involving this product or any related accessories or parts.

2.

Route the power supply connecting wire through the door

frame and into the wire access hole in the top of the magnet
housing. Connecting wire should be of sufficient gauge for
the lock being installed and the distance being run. See table
for current draw specifications and wire gauge chart.

Installation Instructions

PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO 

THE END-USER UPON COMPLETION OF THE INSTALLATION.

Summary of Contents for IntelliMag 8310-IQ

Page 1: ...nough to meet the magnet surface Refer to the Product Accessories Guide section of the Installation Instructions for further information 11 Installation of this product should be done by an experienced installer with knowledge of this product NOTE It is highly recommended that thread locking compound be applied to all screws during installation to reduce chance of screws loosening over extended ti...

Page 2: ...ents Alarm Alarm Status Remote Indication When the door is closed and an illegal armature plate is detected the common contact TB1 6 and the normally open contact TB1 7 are activated for the preset period of time The alarm status relay contacts are rated at 30VDC 2 0 amps maximum Alarm Time Setting Refer to figure 1 JP2 Note 15 or 30 seconds requires one jumper 60 seconds requires no jumper and in...

Page 3: ...dded safety thread locking compound has been provided for the armature plate bolt and the four captive electromagnetic lock mounting screws WARNING Improper installation maintenance inspection or usage of the product or any related accessories or parts may cause the electromagnetic lock armature plate and associated hardware to disengage and fall causing serious bodily injury and property damage P...

Page 4: ... not include a shunted light option Check to see that armature plate is correctly aligned with the electromagnetic lock If there is improper alignment make a 1 4 turn of the armature plate mounting bolt and check for alignment CAUTION The armature plate must remain affixed securely to the door or serious bodily injury or property damage may occur Bolt should be tight enough to hold the armature pl...

Page 5: ...cient space on the frame header to mount the lock The lock mounts to the underside of the L bracket and the L bracket then gets mounted to the doorframe Available in several different sizes and finishes Available for all 8310 and 8320 locks Allows an armature plate to be mounted to a glass or Herculite door that does not have a frame The Glass Door Bracket is a U shaped piece of 1 16 thick materia...

Page 6: ... lowered then a spacer bar can be used to lower the lock from the frame Available in several different heights For use with doors that do not permit the armature plate to be mounted low enough to meet the magnet surface Eg Some aluminum framed commercial glass doors The armature holder can be mounted to whatever frame is available and the armature plate in turn mounted to the holder Available in b...

Page 7: ...00 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1000 14 10 10 1500 12 10 Total One Way Length of 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A Wire Run ft 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 200 16 14 12 12 10 10 250 16 14 12 10 10 10 300 16 12 12 10 10 400 14 12 10 500 14 10 10 750 12 10 1000 10 1500 10 Load Current 24V Load Current 12V Wire Gauge Chart c...

Page 8: ...A 23453 CANADA 210 SHEARSON CRESCENT CAMBRIDGE ON N1T 1J6 PHONE 1 800 265 6630 519 621 7651 FAX 1 800 482 9795 519 621 7939 E MAIL SALES RUTHERFORDCONTROLS COM 8310 IQ 8320 IQ 8330 IQ 8340 IQ Electromagnetic Lock Installation Instructions Continued Maintenance Schedule COMPANY NAME DOOR LOCATION DATE NOTES INITIAL ...

Reviews: