background image

Repair Parts and Maintenance Guide

138

The information contained in this document is subject to change without notice.

BASYS

®

 

Infrared Sensor Activated

NOTE: Turning off water is not necessary, due to integrated automatic stop 

valve.

Remove battery pack assembly by 

lifting out of spout.

Rotate solenoid assembly counter-

clockwise through a 45º angle.

Pull solenoid caddy from faucet.

NOTE: STRAINER (FILTER) CAN 

BE REMOVED, CLEANED AND 

REPLACED AT THIS TIME.

Remove crown by loosening hex 

screw located on underside of spout 

and slide crown down and lift off.

NOTE: Screw is captive within 

faucet body and will not fall out.

REPLACING THE SOLENOID STRAINER (FILTER)

UNLOCK

LOCK

Insert new solenoid caddy at a 

45° angle.
Rotate solenoid caddy clockwise to 

align with arrow, locking the unit 

and opening water path.

Reinsert battery pack assembly.

Slide on crown and secure.

UNLOCK

LOCK

SPARE

FILTER

SPARE

FILTER

Faucets and  Soap Dispensers

Repair Parts and Maintenance Guide

139

The information contained in this document is subject to change without notice.

Wait, until LED fl ashes GREEN.

2x + 

1x 5 sec

1x

2x

3x

4x

6x - Factory Setting

7x

8x

5x

2x + 

1x 5 sec

1x

2x

3x

4x

6x - Factory Setting

7x

8x

5x

2x + 

1x 5 sec

1x

2x

3x

4x

6x - Factory Setting

7x

8x

5x

2x + 

1x 5 sec

1x

2x

3x

4x

6x - Factory Setting

7x

8x

5x

BASYS

®

 

Infrared Sensor Activated

Factory setting is appropriate for the majority of applications and should not 

require resetting unless under extreme situations.

IR Activation (see page 129).

To enter programming mode 

place fi nger on IR clic for 2 times 

then remove. Light on side of 

crown should blink red to indicate 

programming mode.
Cover IR clic until LED fl ashes 4x - 

hold on until LED fl ashes 1x to 8x, 

from minimum to maximum range. 

See diagram below. Release when 

requested range is reached.

SENSOR RANGE ADJUSTMENT

BATTERY REPLACEMENT

NOTE: Replace Battery when LED1 indicator fl ashes red each time faucet 

is in use or when faucet stops functioning. LED1 is identifi ed by the battery 

symbol.
NOTE: Turning off water is not necessary.

Loosen cover screw and remove 

cover from battery pack.
Install four (4) AA-size batteries 

(supplied) as indicated by the (+) 

and (–) symbols inside the battery 

compartment.
Replace battery pack lid and tighten 

with screwdriver.
NOTE: Insure batteries are installed 

with proper polarity. The cover 

of the case indicates polarity of 

batteries. Improper polarity will not 

harm the faucet. Improper polarity 

will cause the faucet not to operate.

Faucets and

Soap Dispensers

372626_Master_Book_ccg.indd   136

9/18/17   7:53 AM

Reviews: