background image

Repair Parts and Maintenance Guide

140

The information contained in this document is subject to change without notice.

BASYS

®

Infrared Sensor Activated

As the user’s hands enter the 

beam’s effective range, the beam 

is refl ected back into the sensor 

receiver and activates the solenoid 

valve allowing water to fl ow from 

the faucet. Water will fl ow until 

the hands are removed or until the 

faucet reaches its automatic time 

out limit setting.

OPERATION

SET AND FIX TEMPERATURE AND ADJUST HOT LIMIT STOP

Adjust lever to set temperature.

OPTIONAL – To fi x temperature, 

set lever to the desired position, 

then remove lever and plug hole 

with cap.

2.5 mm

Faucet may be adjusted in 10º 

increments.

2.5 mm

This feature will operate the faucet 

every 12 or 24 hours since last 

use, if not used to prevent stagnant 

water conditions.
Default purge duration is two 

minutes.
Consult factory regarding other 

timing options.
IR activation (see above). Cover IR 

clic approximately 24 sec. (ignore 

LED indications during this period). 

Release when requested program 

is reached. (See diagram to right). 

Programming mode will time out 

after 2 minutes if no changes are 

made.

12/24 LINE PURGE FEATURE

1x 24 sec 

...1x

...2x

...3x

+

 ...

Activate 12HR

Deactivate

Activate 24HR

1x 24 sec 

...1x

...2x

...3x

+

 ...

Activate 12HR

Deactivate

Activate 24HR

Optional Hot Limit Stop Adjustment 

– To adjust the hot/cold mix (factory 

set at 50/50) remove the lever.
Check to make sure dot is in 

center position before beginning 

adjustment.

2.5 mm

  

Steps to  

Default  IR

 Function 

Activate  Function 

Setting 

Clic

 

IR Activation

  Cover IR clic approximately for 2 sec.  

–– 

––

  

until LED will fl ash GREEN 1x - then remove 

  

fi nger from IR clic (Active for 5 sec.) 

 

Cleaning

 

IR activation; Cover IR clic 2x - confi rmation  

2 min. 

––

 

Mode

 

of the function is active by a couple fl ashes 

  

by the LED; to return to normal operation cover 

  

IR clic 1x or the faucet will automatically return 

  

to normal function after 2 min.

 

12/24

 

Line

 

See below. 

Off 

Off

 

Purge

  

  12HR

 

Feature

  

  24HR

 

Sensor

 

See page 130. 

1-8

 

Range

 

Adjustment

 

Reset

 

IR activation; Cover IR clic 2x; LED will fl ash 5x 

Manually  ––

 

Electronics

 

Cover IR clic 1x for 5 sec. until LED 

  

fl ashes 4x, then remove fi nger from IR clic

  

Wait for 20 sec.

  

(After 10 sec. water will fl ow for 6 sec. 

  

and automatically adjust to environment)

Security Off

 

After 90 seconds (max) of hand and/or object  

On 

––

  

within sensor appears permanent, waterfl ow 

  

will stop and will remeasure environment

Please contact factory for more extensive programming options.

Faucets and  Soap Dispensers

Repair Parts and Maintenance Guide

141

The information contained in this document is subject to change without notice.

BASYS

®

 

Infrared Sensor Activated

Remove crown by loosening hex 

screw located on underside of spout 

and slide crown down and lift off.

NOTE: Screw is captive within 

faucet body and will not fall out.

UPGRADE FAUCET FUNCTIONALITY

LED DISPLAY DIAGNOSTIC CODES

UNLOCK

LOCK

LOCK

UNLOCK

LOCK

LOCK

UNLOCK

LOCK

LOCK

Place new crown on faucet by sliding 

onto spout and tightening hex screw 

on underside of spout.

NOTE: All electronics are fully 

encapsulated in the crown 

and thus protected from the 

environment and easy to replace 

or upgrade.

RED

GREEN

RED

GREEN

RED

RED

RED

RED

RED

GREEN

GREEN

GREEN

RED

RED

RED

RED LED1

GREEN LED2

RED LED3

Function

LED1 LED2

LED3

Description 1

Description 2

Start Up Boot

LED1 and LED2 alternate blinking

Fast Toggle

Battery Check after Start Up

LED1 on for 2 sec, if battery greater than 3.5V

Line Power Check after Start Up

LED3 on for 2 sec, if line power greater than 3.5V

IR Adjust Process

LED1 blinking while IR adjusts

Few seconds

IR Adjust IR

LED2 on for 2 sec, if adjustment OK

Battery Low

LED1 blinks 3x, if battery is less than warning level

Only while in detection mode

Battery Empty

LED1 double flashes 3x, if battery is 

less than empty level

Only while in detection mode

Valve Error

LED3 double flashes 3x, if valve 

current error; flash after the 3rd error,

off after the 3rd good operation

Flashes after the 3rd error, off 

after the 3rd good operation

IR Activation

LED2 on for 2 sec, if IR-click has been activated

After 5 sec. automatically back to 

operating mode

Cleaning Mode

LED1 4-in-1 flash, if cleaning mode is activated

During “Cleaning Mode” is activated 

Permanent 4-in-1 flashes

COLOR LEDs BLINKING

COLOR LEDs ON

Faucets and

Soap Dispensers

372626_Master_Book_ccg.indd   139

9/18/17   7:53 AM

Reviews: