21
5453
11
2021
-
SE IP 30 s2 & SE IP 40 s2
MG_0067
6 1265
5-LEAD
Y-CONNECTOR
6 1265
5-LEAD
Y-CONNECTOR
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1278-xxM
5-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
STERN
BOW
STERN
BOW
STERN
6 1278-xxM
5-LEAD
CONTROL CABLE
Switch
5A fuse
Switch
5A fuse
Common negative
10A fuse
+
-
+
-
6 1274
4-LEAD
Y-CONNECTOR
STERN
BOW
STERN
BOW
STERN
xA fuse
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1277-xxM
4-LEAD
CONTROL CABLE
6 1274
4-LEAD
Y-CONNECTOR
xA fuse
Common negative
10A fuse
+
+
-
-
With Automatic Main Switch:
With Manual Main Switch:
Visual Wiring Diagram
IMPORTANT
Check the following with the main switch in the off position
After all electrical connections have been completed check with an ohm meter that there is no electrical connection between electro motor body and
positive terminal on the motor and between the electro motor body and the negative (A1) terminal on the motor. If you feel unsure about how to
perform this check, contact skilled personnel for guidance
Common negative MUST be wired when using control panel 8940 and 8909C if separate battery banks are installed. (Bow and Stern thrusters
combined)
To define appropriate (-) cable and
fuse size contact a skilled electrician
To define appropriate (-) cable and
fuse size contact a skilled electrician