PHC-3
PARAMETERS - 06 Digital Inputs
No.
Name/Value
Description
0601
0602
0604
D-INPUT 1
D-INPUT 2
D-INPUT 4
Sets a function for the selected digital input. Any function can be set to any digital input. The input is
activated when the potential free contact is Closed to B+ or input is +24V.
If the number in front of the value/function name is negative (like -1 START POWERPACK) then the input is
activated when the potential free contact is Open or input is 0V.
If two or more inputs is set for the same function, then the function will be activated if only one of the inputs
is active and all inputs must be deactivated to deactivate the function.
0-NOT IN USE (default)
Digital input is not in use and deactivated
-1/1-START POWERPACK
When the input is activated the AC power-pack will start running.
For this function to work the VFD(AC) must be selected in parameter 1001-STABILIZER CONFIG and
parameter 1002-AUTO-START AC PUMP must also be set to ON.
-2/2-PRESSURE FILTER
When the input is activated for 5 seconds a pressure fi lter warning signal will be sent to all joystick panels
and alert the captain that the fi lter needs to be replaced.
-3/3-RETURN FILTER
When the input is activated for 5 seconds a return fi lter warning signal will be sent to all joystick panels and
alert the captain that the fi lter needs to be replaced.
Menu - Parameters
MC_0201
4.5
PARAMETERS - 10 Stabilizer
No.
Name/Value
Description
1001
STABILIZER CONFIG
Activating stabilizer confi guration.
NONE (default)
Disables stabilizer power pack function
PTO and VFD(AC)
Enables stabilizer to run from PTO and VFD
PTO ONLY
Enables stabilizer to run from PTO pressure only
VFD(AC) ONLY
Enables stabilizer to run from AC power only
1002
AUTO-START AC PUMP
Defi nes if the AC power pack should start automatically.
OFF
AC power pack will not start automatically.
ON (default)
AC power pack starts automatically when stabilizer required it to start.
1003
PRESSURE SETPOINT
Stabilizer AC power pack pressure setpoint
10bar – 1010 PRESSURE
SENSOR RANGE (default
70bar)
Pressure in steps of 1bar
1004
PID P FACTOR
AC power pack PID P factor
0.1 - 1000.0 (default 8.0)
In steps of 0.1
1005
PID I FACTOR
AC power pack PID I factor
0.0 - 1000.0 (default 0.0)
In steps of 0.1
1006
PID D FACTOR
AC power pack PID D factor
0.0 - 1000.0 (default 0.0)
In steps of 0.1
1007
REDUCED POWER
DISABLE (default)
Disables the function and AC power pack will operate at set-point set in parameter 1003
ENABLE
Will operate the AC power pack with a lower set-point to save power
1008
REDUCED POW.LEVEL
Setting the reduced power level to operate at percent level of pressure set-point (parameter 1003). The
reduced level in bar must not go lower than the working pressure of the accumulator.
50% - 100% (default 70%) Level in steps of 1%.
1009
PTO PUMP PRESSURE
DETECT LEVEL
Defi nes detection level for PTO standby pressure if parameter 0104 SYSTEM PRESSURE is set to ANALOG
INPUT. Pressure above level indicates that main engines are running.
0bar – 100bar (default
10bar)
Pressure in steps of 1bar.
1010
PRESSURE SENSOR RANGE Sets the stabilizer pressure sensor range (4-20mA sensor)
50bar - 1000bar (default
160bar)
Range in steps of 10bar.
1011
PTO ENGINE INSTANCE
This parameter is only in use when any digital output is set to function -8/8-STAB.PTO P.UNLOAD. Then this
parameter must defi ne the instance of the engine which the PTO pump is connected to.
This also require that the engine is connected to the NMEA2000 bus on a GW-1 gateway and that the engine
are broadcasting PGN127488 Engine Parameters.
0-255 (default 255)
Engines begins on the Port side with instance number 0 and increments towards Starboard.
When editing one up from value 255 will jump to value 0.
1012
VFD FLOW COMPENSATION If the AC power-pack is having a hard time to retain the pressure at set-point. Then this factor will give a
compensation to the stabilizer pressure regulation when running from AC power-pack.
If value is set to 0.0 then there is no compensation.
0.0 - 2.0 (default 0.0)
In steps of 0.1
1013
PTO OVER-PRESSURE
FAULT LEVEL
The stabilizer overpressure fault level when stabilizer gets oil pressure from PTO.
50bar-500bar (default
130bar)
In steps of 1bar
1020
VFD MIN SPEED
Sets VFD Minimum Speed
MIN LIMIT – MAX SPEED
(default 200rpm)
The value is limited to VFD settings and parameter 1021 VFD MAX SPEED.
In steps of 10rpm.
Menu - Parameters
MC_0201