10. Assemble the high-pressure pump according to the manual included with the pump.
a. Connect the high-pressure hose.
b. Fill up the container with oil.
c. Use the pump to bleed out the air in the hose.
d. When free oil flows connect the hose to the shaft ON fi tting.
e. Fitting to shaft
11. Lock the actuator cylinders in its absolute setting then also position the fi n as far outboard as possible without hitting the outer edge of the hull.
MC_0219
MG_0342
High pressure hose
(part no. 227957A/ 4000)
Oil container
(part no. LHMF 300/I)
ISO VG 100
Bleed out air
(part no. 226400-226402)
IMPORTANT
OFF port must be open for
drainage
a
b
c
d
e
11
10
Connect hose to ON fitting
(part no. 1014357 A)
W.L.
100 mm
Boat Envelope
Lower limit for fin
Upper limit for fin
Hull