10
2933
4
2019
-
SH 240 & SH 320
Installation Pre-check
EN
Temporarily set up the complete installation to ensure no confl icts during the fi nal operation of the thruster.
1. Use silicon in the 4 corners of the SRF fl ange and set it over the hatch. Attach the motor unit to the SRF fl ange with 4 corner screws to hold
securely in place. use silicon to attach the hatch to the propeller unit. (NB: Ensure correct orientation for the thruster to open the hatch facing the
direction of water fl ow. Remember attachment is for temporary checking of thruster operation only.)
2. Temporarily connect 12 or 24 DC cables (refer to the label on actuators for correct voltage) to the 6 mm cables on the terminals on the controller.
Set switch no. 4 on the DIP-switch marked “SETTINGS” to ON. Remove the wooden safety part located above the propeller.
3. Press “DOWN” to extend the retract mechanism and check the hatch opens fully without touching the hull. If the hatch is obstructed by the hull, lift
the aft end of the SRF fl ange maintaining the reference height in front - until the hatch clears the hull when opened.
4. Press “UP” to retract the propeller mechanism. Ensure when the hatch is closed extra pressure is on the contact surface between the hatch and
the hull only. If the hatch is not closing with pressure on the contact surfaces the entire SRF fl ange must be raised. (NB:
After all, pre-checks are compleated the SR system can be installed.
MC_0068
!
Please refer to the graphic for special considerations relating to your model
!
MG_0182
Controller
Controller
SETTINGS
UP
DOWN
FAULT
STATUS
(FUSE)
ON
1 2 3 4
Hatch does not close
with pressure
Conflict with hatch
and hull
Apply silicon to
corner areas
Remove wooden
installation part
From power
supply
+
+
-
Hatch closed with
pressure
hatch opens
without conflict
2
3
4
1
MG_0183
Conflict with hatch
and hull
Hatch closed with
pressure
hatch opens
without conflict
3
1
2
hatch opens
without conflict
Raise SRF flange
on stern end
Use wedge to prop
the SRF flange to
required height