background image

CONTENTS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PAGE

Ratings and Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Installation Requirements:

Boiler Location  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Clearances  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Vent Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Vent Piping  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Installing Water trim  . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Piping for Tankless heater . . . . . . . . . . . . . . . . . . . . . . . .5

Installing Burner  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Oil Supply Piping  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Wiring the Boiler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Operating Instructions:

Precautions Before Starting  . . . . . . . . . . . . . . . . . . . . . .6

Start-up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Cleaning and Filling New Water Boiler  . . . . . . . . . . . . . .6

Wiring Diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-9

Burner Data:

Riello  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Heatwise  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Care and Maintenance:

Extended Shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Freezing Protection  . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Oil Burner  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

General Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . .13

SAFETY WARNING:

KEEP  BOILER  AREA  CLEAR  AND  FREE  FROM 

COMBUSTIBLE 

MATERIALS, 

GASOLINE 

AND 

OTHER 

FLAMMABLE 

VAPORS 

AND 

LIQUIDS. 

FAILURE 

TO 

ADHERE 

TO 

ABOVE 

SAFETY

WARNING,  MAY  RESULT  IN  PERSONAL  INJURY 

OR DEATH AND PROPERTY DAMAGE.

IMPORTANT:

The installation of this equipment must conform

to  the  requirements  of  the  authority  having  jurisdiction  or,  in

the  absence  of  such  requirements,  to  the  Installation  of  Oil

Burning Equipment, ANSI/NFPA 31, latest edition, and to the

National  Electrical  Code  ANSI/NFPA  70,  latest  edition.   The

installation must also conform to the additional requirements in

this  Slant/Fin  Instruction  Manual.   Where  there  is  any  differ-

ence, the more stringent requirement shall govern.

In addition, where required by the authority having jurisdiction,

the  installation  must  conform  to  American  Society  of

Mechanical  Engineers  Safety  Code  for  Controls  and  Safety

Devices for Automatically Fired Boilers, No. CSD-1, latest 

edition.

THIS MANUAL MUST BE LEFT WITH OWNER AND

SHOULD BE HUNG ON OR ADJACENT TO THE

BOILER FOR REFERENCE.

IMPORTANT:  This boiler must be installed by a trained, 

experienced,  service  technician,  licensed  for  the  installation

and servicing of oil burning equipment or otherwise qualified by

the authorities having jurisdiction over the installation.

Publication No. TRDV-40

P/N 432750  Printed in U.S.A. 308

THIS  BOILER  OPERATES  WITH  POSITIVE  PRESSURE  IN

THE  FLUE  AND  OVER  FIRE,  ALL  SEALS  MUST  BE  IN

PLACE  WHEN  OPERATING  THE  BOILER.  ALL  VENTING

MUST  BE  INSTALLED  AND  SEALED  ACCORDING TO THE

VENT MANUFACTURER’S INSTRUCTIONS.

DIRECT VENT OIL-FIRED WATER BOILER/NO. 2 OIL

INSTALLATION AND OPERATING INSTRUCTIONS

INTREPID

TRDV Series

CAUTION

The information in this manual must be followed exactly

to avoid personal injury, property damage or loss of life.

SERVICE COMPANY

Name ______________________________________

Address ____________________________________

__________________________________________

Telephone __________________________________

Model # ____________________________________

Serial # ____________________________________

READ AND SAVE THESE INSTRUCTIONS FOR REFERENCE.

Summary of Contents for INTREPID TRDV Series

Page 1: ...In addition where required by the authority having jurisdiction the installation must conform to American Society of Mechanical Engineers Safety Code for Controls and Safety Devices for Automatically...

Page 2: ...ted within the area to be heated the boiler may be selected on the basis of gross D O E capacity output The net AHRI output ratings shown are based on an allowance for piping and pickup of 1 15 water...

Page 3: ...ion should not be mounted directly above or within 3 ft horizontally from an oil tank vent VENT PIPING A The vent piping minimum bend radius is 12 B Place metal strapping every 36 to support vent pipe...

Page 4: ...4 INTREPID TRDV...

Page 5: ...ansion tank and air scoop should be located near the pump suction See Figure 4 Alternate Pump Location PIPING TANKLESS HEATER if used I Heater capacities are listed on page 2 II Pipe the built in tank...

Page 6: ...DO NOT FIRE into an empty boiler B Be prepared to heat raw water to at least 180 F as soon as it is introduced into the boiler This procedure will remove dissolved corrosive gases C Provide drain line...

Page 7: ...INTREPID TRDV 7 SEE Adjusting Settings Error Codes for L7224C L7248L on page 8 See page 8 for other Primaries...

Page 8: ...everting to default settings or has stopped running the Outdoor Reset algorithms The warnings are cleared when the issue s is resolved b To clear Err 8 condition depress and hold all three user keys s...

Page 9: ...INTREPID TRDV 9 Basic Module Wiring less circulator...

Page 10: ...nto Combustion Chamber TURBULATOR SETTING 1 Loosen nut 1 then turn the screw 2 until the index marker 3 is aligned with the correct index number 2 Retighten the retaining nut 1 The numbers on the cast...

Page 11: ...lockwise indicator to increase combustion air turn the screw clockwise indicator to decrease combustion air 3 The final position of the air damper will vary on each installation Use instruments to est...

Page 12: ...kwise the burner head will move inside the blast tube AWAY from the end cone This achieves lower firing rates Similarly by turning the head adjustment screw counter clock wise the burner head will mov...

Page 13: ...with neutral mineral oil 9 Close main cast iron burner door door on which burner is mounted Make sure that the entire seal fiberglass rope is making good contact with the boiler casting when replacin...

Page 14: ...14 INTREPID TRDV Notes...

Page 15: ...INTREPID TRDV 15 Notes...

Page 16: ...SLANT FIN CORPORATION Greenvale N Y 11548 Phone 516 484 2600 FAX 516 484 5921 Canada Slant Fin LTD LTEE Mississauga Ontario www slantfin com Copyright 2011...

Reviews: