background image

REQUEST FOR CARAVAN SYSTEM RATING PLATE

NOTE

:

INDICATE ACCURATELY

Some model numbers are similar, such as GGT-600 and GGT-600E etc.

PLEASE USE CARE TO MAKE SURE THE PROPER SYSTEM MODEL IS INDICATED 

COMPLETE WITH LETTER SUFFIX.

BE ACCURATE!

INCLUDE ALL LETTERS AND ZEROS, ENTER ALL INFORMATION ASKED FOR!

USE A SEPARATE FORM FOR EACH SYSTEM

Slant/Fin Tech

Service

FAX THIS REQUEST TO:

516-484-6958

PHONE

:

516-484-2600

Requested by:

Mail to:

Phone:

Phone:

Required

Required

Each individual Caravan module is shipped with a rating 
plate bearing the model, serial number, capacities and 
certifications for that module. A modular boiler system is a 

single boiler. To meet local requirements, a system rating 
plate will be issued by Slant/Fin upon request. Just 
provide the information indicated on this page.

Type of System:

Gas

Oil

Water

Steam

Natural Gas

Propane

Dual Fuel

INDICATE SYSTEM MODEL 

NUMBER BELOW:

INDICATE SERIAL NUMBERS OF INDIVIDUAL MODULES 

(Please write legibly)

DO NOT WRITE BELOW THIS LINE

FOR SLANT/FIN USE ONLY

System serial number assigned 

Done by

SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600

FAX: (516) 484-5921

Canada: Slant/Fin 

LTD/LTEE

, Mississauga, Ontario

www.slantfin.com

Summary of Contents for CARAVAN GGHT-1050E

Page 1: ...al electri cal codes The unit must be electrically grounded if an external power source is used In Canada the installation must be in accordance with standards CGA B149 1 and B149 2 installation codes...

Page 2: ...394 1932 11202 1680 57 7 80 60 61 8 3660 301 16 665 8 10 1323 32 253 16 115 16 15 10 3 GGHT 2450E 7 GG 350HES 2450 1995 11571 1736 59 6 81 40 72 1 4270 301 16 671 8 9 1323 32 253 16 115 16 18 6 3 GGHT...

Page 3: ...3 Design Data Max ASME Working Pressure 100 psi Power Requirements 120 volts 60 HZ 34 amps per module Figure 1 Gas Caravan dimensions and typical piping hot water models...

Page 4: ...r piping for variable circulation Figure 3 Supply and return piping locations Figure 4 Instantaneous tankless coil two temperature with recirculation Figure 5 Storage tank from tankless coil with reci...

Page 5: ...cify 30 50 or 100 psi Control header unmounted one per system Draft hoods unmounted OPTIONAL EQUIPMENT Hot water supply and return header assemblies Control panel with automatic lead lag Spark ignitio...

Page 6: ...opening near the floor below burner air inlet and one louvered opening near the ceiling above the highest draft regulator each opening with a minimum FREE air passage area of 1 square inch per 4000 B...

Page 7: ...7 Figure 8 Typical layouts for gas fired systems...

Page 8: ...p obstruction A vent cap should be used where permitted for additional protection against adverse wind conditions and precipitation The National Board of Fire Underwriters recommend that the chimney s...

Page 9: ...Table 2a depicts the proper diameter Dim C of the connec tor rise depending upon its total length top of the draft hoods to the breeching above Based on single row of modules with no elbows NOTE For c...

Page 10: ...1 2 34 3 11 1 1 4 2 19 1 37 1 07 0 082 6 54 2 94 3 27 4 35 1 1 2 2 63 1 64 1 29 0 098 7 84 3 52 3 92 5 21 2 3 55 2 23 1 74 1 320 10 60 4 77 5 30 7 05 3 5 72 3 59 2 81 2 130 17 08 7 69 8 84 11 40 Model...

Page 11: ...ize only as many modules as the system load requires Only one stage cycles at a time The other stages remain off or operate continuously thereby performing at peak efficiency For example in a 10 modul...

Page 12: ...increases The control activates only the number of stages required to maintain the required supply water temperature 2 Setpoint temperature The control maintains a set supply water temperature The co...

Page 13: ...13 FIELD WIRING AT MODULES...

Page 14: ...14 SC 3 SYSTEM WIRING DIAGRAM...

Page 15: ...15 SC 3 LADDER WIRING DIAGRAM...

Page 16: ...16 SC 9 SPACE HEATING WIRING DIAGRAM...

Page 17: ...17 SC 9 SPACE HEATING LADDER WIRING DIAGRAM...

Page 18: ...18 SC 9 SPACE AND DOMESTIC HOT WATER WIRING DIAGRAM...

Page 19: ...19 SC 9 SPACE AND DOMESTIC HOT WATER LADDER WIRING DIAGRAM...

Page 20: ...stallation If any parts are found to be defective in material or workmanship Slant Fin will repair or replace the defective parts SECOND THROUGH TENTH YEAR LIMITED WARRANTY FOR CAST IRON SECTION ASSEM...

Page 21: ...bustion chamber tankless heater exhaust and air inlet pip ing burner enclosure mixing elbow gas and air orifice blower assembly air filter and electrical and mechanical components fur nished to Slant...

Page 22: ...22 NOTES...

Page 23: ...CARAVAN SYSTEM RATING PLATE System rating plate format for Caravan modular boiler system System rating plates are available upon request using the form on the back cover 23...

Page 24: ...s shipped with a rating plate bearing the model serial number capacities and certifications for that module A modular boiler system is a single boiler To meet local requirements a system rating plate...

Reviews: