BOILER WARRANTIES

Lifetime Limited Warranty

for Residential Cast-iron Hot Water

Boilers in Household Use

Gas Models:

Sentinel, Sentry, Galaxy and Victory 

Oil Models:

Intrepid, Liberty, Liberty II, XL-2000, EC

Series

Electric Models:

Monitron

FIRST-YEAR WARRANTY INCLUDES:

Repair or replacement for a period of one year after original installa-

tion of all parts found to be defectively manufactured.

LIFETIME  LIMITED  WARRANTY  OF  CAST-IRON  SECTIONS

is

effective for as long as the boiler is owned by the original purchaser

or  for  25  years,  whichever  time  period  is  longer.  The  warranty

includes  repair  or  replacement  of  cast  iron  sections  found  to  be

defectively  manufactured,  at  a  cost  to  consumer  equal  to  the  per-

centage indicated below of the manufacturer's then list price for the

replacement parts:

This warranty extends only to boilers in household use. 

See “Additional Warranty Terms” section for more details.

Limited Ten-Year Warranty

for Residential Application Cast-iron 

Steam Boilers

This warranty extends only to steam boilers and Jaguars in house-

hold use in buildings with one or two family dwelling units and which

have been properly installed by a qualified heating contractor whose

principal occupation is in the installation of heating equipment. Also,

this warranty applies only to the first retail purchaser and only if the

boiler has remained at all times in the location at which it was origi-

nally installed.  

FIRST-YEAR LIMITED WARRANTY FOR RESIDENTIAL STEAM

BOILERS:

Slant/Fin  warrants  its  residential  steam  boilers  to  be  free  from

defects in material and workmanship for one year from date of orig-

inal installation.  If any parts are found to be defective in material or

workmanship, Slant/Fin will repair or replace the defective parts.

SECOND THROUGH TENTH YEAR  LIMITED WARRANTY  FOR

CAST-IRON  SECTION  ASSEMBLY  OF  RESIDENTIAL  STEAM

BOILERS:

Slant/Fin  warrants  the  cast-iron  section  assembly  of  its  residential

steam boilers to be free of defects in material and workmanship for

the  second  through  the  tenth  year  following  the  date  of  original

installation.  If any sections are found to be defective during this peri-

od,  Slant/Fin  will  repair  or  replace  the  section  or,  at  its  option,  the

entire heat exchanger.

See “Additional Warranty Terms” section for more details.

Limited Ten-Year Warranty

for Caravan Modular, Jaguar and

Commercial Application of Individual

Cast-Iron Boilers in Hot Water and Steam

Heating Applications.

WARRANTY INCLUDES:

FIRST YEAR:  Repair  or  replacement  in  accordance  with  warranty

service procedure, for a period of one year after original installation,

of all parts found to be defectively manufactured.

SECOND THROUGH TENTH YEAR: Repair or replace for the sec-

ond through tenth year after original installation, of the cast iron or

cast  aluminum  heat  exchanger  found  to  be  defectively  manufac-

tured,  at  no  cost  for  the  replacement  heat  exchanger.  Second

through tenth year warranty is for the heat exchanger only.

This warranty extends only to boilers installed in closed loop space

heating applications and domestic hot water applications. A proper-

ly sized heat exchanger must be used to heat the domestic water. 

See “Additional Warranty Terms” section for more details.

2 thru 10

0%

18

40%

11

5%

19

45%

12

10%

20

50%

13

15%

21

55%

14

20%

22

60%

15

25%

23

65%

16

30%

24

70%

17

35%

25 & after

75%

Year of

Percentage paid by

consumer (of list price

at time of claim)

Percentage paid by

consumer (of list price

at time of claim)

Year of

Summary of Contents for CARAVAN GGHT-1050E

Page 1: ...al electri cal codes The unit must be electrically grounded if an external power source is used In Canada the installation must be in accordance with standards CGA B149 1 and B149 2 installation codes...

Page 2: ...394 1932 11202 1680 57 7 80 60 61 8 3660 301 16 665 8 10 1323 32 253 16 115 16 15 10 3 GGHT 2450E 7 GG 350HES 2450 1995 11571 1736 59 6 81 40 72 1 4270 301 16 671 8 9 1323 32 253 16 115 16 18 6 3 GGHT...

Page 3: ...3 Design Data Max ASME Working Pressure 100 psi Power Requirements 120 volts 60 HZ 34 amps per module Figure 1 Gas Caravan dimensions and typical piping hot water models...

Page 4: ...r piping for variable circulation Figure 3 Supply and return piping locations Figure 4 Instantaneous tankless coil two temperature with recirculation Figure 5 Storage tank from tankless coil with reci...

Page 5: ...cify 30 50 or 100 psi Control header unmounted one per system Draft hoods unmounted OPTIONAL EQUIPMENT Hot water supply and return header assemblies Control panel with automatic lead lag Spark ignitio...

Page 6: ...opening near the floor below burner air inlet and one louvered opening near the ceiling above the highest draft regulator each opening with a minimum FREE air passage area of 1 square inch per 4000 B...

Page 7: ...7 Figure 8 Typical layouts for gas fired systems...

Page 8: ...p obstruction A vent cap should be used where permitted for additional protection against adverse wind conditions and precipitation The National Board of Fire Underwriters recommend that the chimney s...

Page 9: ...Table 2a depicts the proper diameter Dim C of the connec tor rise depending upon its total length top of the draft hoods to the breeching above Based on single row of modules with no elbows NOTE For c...

Page 10: ...1 2 34 3 11 1 1 4 2 19 1 37 1 07 0 082 6 54 2 94 3 27 4 35 1 1 2 2 63 1 64 1 29 0 098 7 84 3 52 3 92 5 21 2 3 55 2 23 1 74 1 320 10 60 4 77 5 30 7 05 3 5 72 3 59 2 81 2 130 17 08 7 69 8 84 11 40 Model...

Page 11: ...ize only as many modules as the system load requires Only one stage cycles at a time The other stages remain off or operate continuously thereby performing at peak efficiency For example in a 10 modul...

Page 12: ...increases The control activates only the number of stages required to maintain the required supply water temperature 2 Setpoint temperature The control maintains a set supply water temperature The co...

Page 13: ...13 FIELD WIRING AT MODULES...

Page 14: ...14 SC 3 SYSTEM WIRING DIAGRAM...

Page 15: ...15 SC 3 LADDER WIRING DIAGRAM...

Page 16: ...16 SC 9 SPACE HEATING WIRING DIAGRAM...

Page 17: ...17 SC 9 SPACE HEATING LADDER WIRING DIAGRAM...

Page 18: ...18 SC 9 SPACE AND DOMESTIC HOT WATER WIRING DIAGRAM...

Page 19: ...19 SC 9 SPACE AND DOMESTIC HOT WATER LADDER WIRING DIAGRAM...

Page 20: ...stallation If any parts are found to be defective in material or workmanship Slant Fin will repair or replace the defective parts SECOND THROUGH TENTH YEAR LIMITED WARRANTY FOR CAST IRON SECTION ASSEM...

Page 21: ...bustion chamber tankless heater exhaust and air inlet pip ing burner enclosure mixing elbow gas and air orifice blower assembly air filter and electrical and mechanical components fur nished to Slant...

Page 22: ...22 NOTES...

Page 23: ...CARAVAN SYSTEM RATING PLATE System rating plate format for Caravan modular boiler system System rating plates are available upon request using the form on the back cover 23...

Page 24: ...s shipped with a rating plate bearing the model serial number capacities and certifications for that module A modular boiler system is a single boiler To meet local requirements a system rating plate...