Page 16
SkyVision Linx 300 Pre-Install • REV2
2-9. Network
a. Network Drops and Required Ports
Up to eight (8) Static IP network drops are required for the following components (if installed), to enable
full system function, configuration, and diagnostics.
Required or
w/Option
Device
Lan Drop
Location
TCP Ports
Required
UDP Ports
Required
Notes
Required
Primary
Touch Panel
Touch Panel
22
SVIS-AUD
Audio DSP
(Nexia)
Rack
12001
12000
SVIS-DCSS
DCSS
Rack
21, 22, 80, 443,
554, 3306,
(10000 - 10400
and 11000 -
11400 are only
for DCSS ot
DCSS streams)
6970
through
6999
For DCSS to DCSS (room
to room) streaming, the
network mus pass multicast
addresses in the range of
239.192.0.0 to 239.193.0.0
SVIS-OBC
PC1
Rack unless
hospital provided
and not at rack
Standard
SVIS-OBC
PC2
Rack unless
hospital provided
and not at rack
Standard
SVIS-OBC
PC3
Rack unless
hospital provided
and not at rack
Standard
w/ hospital
provided
Network
Printer
Network
Printer
Printer Location
Standard
b. Analog Phone Line Drop
One anlog phone line is required for the audio conference option
Required or w/Option
Device
Drop Location
SVIS-AUD
Audio DSP (Nexia)
Rack