REFERENCE

GAS PIPE SIZING

Length of Pipe in Feet

1/2”

3/4”

1”

1 - 1/4”

1 - 1/2”

2”

2 - 2 1/2”

3”

4”

10

275

567

1071

2205

3307

6221

10140

17990

35710

20

189

393

732

1496

2299

4331

7046

12510

25520

30

152

315

590

1212

1858

3465

5695

10110

20620

40

129

267

504

1039

1559

2992

4778

8481

17300

50

114

237

448

913

1417

2646

4343

7708

15730

60

103

217

409

834

1275

2394

3908

6936

14150

70

89

185

346

724

1086

2047

3329

5908

12050

80

78

162

307

630

976

1811

2991

5309

10830

90

69

146

275

567

866

1606

2654

4711

9613

100

63

132

252

511

787

1496

2412

4281

8736

125

54

112

209

439

665

1282

2083

3618

7382

150

48

100

185

390

590

1138

1808

3210

6549

175

43

90

168

353

534

1030

1637

2905

5927

200

40

83

155

325

491

947

1505

2671

5450

300

37

77

144

303

458

887

1404

2492

5084

NATURAL GAS : PIPE SIZING CHART

Natural Gas (NG) flow is given in 
thousands of BTU/hr. = 1 cubic 
foot of NG gas - 1000 BTU

Nominal pressure at the burner 
for Natural Gas is 3.5” of water 
column. (Typical machine supply 
5”-7”)

Pipe length must include 
additional length for all fittings. 
Add approximately 5 feet of pipe 
per fitting.

Natural Gas Example: A machine 
with a burner that requires 
440,000 BTU would need a 1 -1/4” 
pipe for a 20” long run. 

LIQUID PROPANE : PIPE SIZING CHART

NOTE: The sizing charts above list the specific pipe sizes required for the amount of BTU’s for a new gas line installations. If you 
are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper 
pressure. 

This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel 

Gas Code - current edition) for more details.

Length of Pipe in Feet

1/2”

3/4”

1”

1 - 1/4”

1 - 1/2”

2”

2 - 2 1/2”

3”

4”

10

108

230

387

793

1237

2259

3640

6434

-

20

75

160

280

569

877

1610

2613

5236

9521

30

61

129

224

471

719

1335

2165

4107

7859

40

52

110

196

401

635

1143

1867

3258

6795

50

46

98

177

364

560

1041

1680

2936

6142

60

42

89

159

336

513

957

1559

2684

5647

70

38

82

149

317

476

896

1447

2492

5250

80

36

76

140

239

443

840

1353

2315

4900

90

33

71

133

275

420

793

1288

2203

4667

100

32

68

126

266

411

775

1246

2128

4518

125

28

60

117

243

369

700

1143

1904

4065

150

25

54

105

215

327

625

1008

1689

3645

175

23

50

93

196

303

583

993

1554

3370

200

22

47

84

182

280

541

877

1437

3160

300

17

37

70

145

224

439

686

1139

2539

Liquid Propane (LP) Gas flow is 
given in thousands of BTU/hr.  =
1 cubic foot of LP gas - 2500 BTU.

This chart refers to low pressure LP, 
after regulation, Standard nominal 
pressure at the burner for Liquid 
Propane Gas is 11” of water column.

Pipe length must include additional 
length for all fittings. Add 
approximately 5 feet of pipe per 
fitting.

LP Example: A machine with a 
burner that requires 440,000 BTU 
would need a 1” pipe for a 20’ long 
run. 

GAS PIPE SIZING CHART

Table 4 

Gas pipe sizing chart

f i r e - p a r t s . c o m

Summary of Contents for Firegear Outdoors FPB-25SFBSMT-N

Page 1: ...t Disc TFS system FPB 25SFBSTFS P FPB 30SFBSMT N 30 Square Flat Disc MT system FPB 30SFBSMT P FPB 30SFBSTMSI N 30 Square Flat Disc TMSI system FPB 30SFBSTMSI P FPB 30SFBSTFS N 30 Square Flat Disc TFS...

Page 2: ...nt DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicini...

Page 3: ...rial due to rapid temperature differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of...

Page 4: ...B 30SFBSTMSI N FPB 30SFBSTMSI P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 30SFBSTFS N FPB 30SFBSTFS P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 34SFBSMT N FPB 34SFBSMT P 1 16 34 x 34 29 1 2 18 19 69 18 FPB 34SFBS...

Page 5: ...5 0 WC 10 5 WC Table 3 Gas Pressures Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC for Liquid Propane LP at the burner orifice Flex line size and proper gas pipe sizing will...

Page 6: ...the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure Th...

Page 7: ...n of the stainless steel flex gas line supplied with the fire pit IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must...

Page 8: ...ION A minimum of 18 square inches of cross ventilation per side is required to keep the inside of the enclosure dry We recommend installation of a VENT KIT 6x12 See accessory section 8 These products...

Page 9: ...ns Fig s 4 5 and 6 show the use of the flex frame system which provides the ability to easily remove the disc if necessary O N O F F O N O F F Fig 4 Show disc secured under stone caps Fig 5 Show disc...

Page 10: ...se manner Secure into position See Fig 8 Fig 8 Installing OAS assembly to spur burner INSTALLING KEY VALVE The key valve contents 1 key valve 1 key and 1 flange See Fig 9 The valve requires a 1 round...

Page 11: ...ve in place Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple Key Valve Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner Key PU...

Page 12: ...6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause s...

Page 13: ...sually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance MT TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 2 Ensure all gas...

Page 14: ...y Valve Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threa...

Page 15: ...Fig 16 Installing OAS assembly to spur burner Section B Thermocouple Manual Safety TMSI Installation Fig 14 Shows disc secured under stone caps Fig 15 Shows disc secured between layer of block NOTE A...

Page 16: ...e gas valve is secured into the mounting plate with a nut Fig 17 shows an example of a typical installation Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner OFF Gas Valve TC Wire Pie...

Page 17: ...ter than 1 inch overtop of the burner portholes Do NOT cover the screen mesh with any rock or glass It must be free an any debris to operate properly It is important check that the ignitor probes be p...

Page 18: ...disconnected from its fuel supply Natural or LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance Fig 21 C...

Page 19: ...ally a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TMSI TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 3 Ensure all gas...

Page 20: ...s on all male NPT threads not flared fitting side Ensure all connections are tight and check for gas leaks before and after assembly is complete REV 1 4 19 Flare to 3 8 Male Thread Fitting Not Supplie...

Page 21: ...ustrations below show examples of possible installations NOTE Additional methods of supporting the center of the disc underneath or supporting an oversized opening are shown on page 9 in Figs 6 7 Requ...

Page 22: ...smitter and you will see a red LED light at the top of the transmitter glow The red LED light will only be lit when a button is pushed See Fig 27 Fig 26 Weatherproof cover lid installation INSTALLING...

Page 23: ...A maximum of three 3 codes can be programmed to the module After a total of three 3 codes have been pro grammed the memory is full and will not accept any additional codes To clear all codes press and...

Page 24: ...f Cover ON O F F Gas valve and flexible gas lines are supplied gas shut off is not supplied but available in accessories page Flex lines with flared fittings do not require Teflon tape or pipe compoun...

Page 25: ...operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS NOTE It may take several cycles of ON OFF to purge the airflow from the gas lines...

Page 26: ...w for proper flame sensing 5 Ensure orange white leads from module are plugged into the PILOT connection on the valve body 6 Ensure green white leads from module are plugged into the MAIN connection o...

Page 27: ...bstruction between the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system...

Page 28: ...ouple over rainshield on page 24 Fig 31 2 Thermocouple reading should be between 10 20mV Test at the brass ground lead on gas valve and the gold lead at S terminal on the control module If no minimum...

Page 29: ...ack Wire Flat Disc Pan Spur Burner Ignition Hood 7 8 Washer Brass Nut OAS NG Burner Orifice Coupler T 200 9898 46 Flex Conector Note Use joint compound or Teflon tape resistant to all gasses on all ma...

Page 30: ...OT 10 11 12 13 Remote Off S I ADJ IPI POWER Learn AUX 17 19 AA Batteries AA Batteries AA Batteries AA Batteries 20 5 7 LOW HI OFF ON 25 4 6 O N O F F 15 14 16 22 23 24 28 29 18 30 36 37 38 21 Requires...

Page 31: ...rome Plated Key 1 KEY PC 12 x 13 Chrome Cover Plate 1 CVR BVL2CP x 14 Thermocouple for TFS Pilot Must be ordered with item 15 1 ST3 040 1023 x 14 Thermocouple for TMSI Pilot 1 ST3 040 1025 x 15 Thermo...

Page 32: ...eld Replacement Kit not shown 1 TFS IGNT ASSEMBLY x 40 Thermocouple Rainshield Replacement Kit not shown 1 TMS TC ASSEMBLY x 41 Manual Spark Ignitor Module not shown 1 3042 RB x 42 23 Piezo Extension...

Page 33: ...x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare Adapter Model ADP10 OUT 10 wire ADP70 OUT 70 wire Outdoor approved 7 5VDC adapter transformer elimi...

Page 34: ...cation or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemical...

Page 35: ...n to be easily read Note Mounting plate can also be installed into a paver control panel PAVER CP TMSI bracket system Using scissors carefully cutout the template and trace it on your concrete board T...

Page 36: ...IGHT Position 2 Position 1 Position 3 The TMS valve bracket can be oriented in different positions to accommodate different installations Once the bracket and knob are installed the knob may not be or...

Page 37: ...REV 1 8 19 Page 37 Square Flat Disc Fire Pits NOTES fire parts com...

Page 38: ..._____ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 Wh...

Reviews: