background image

REV. 1-8-19  Page 28

Square Flat Disc Fire Pits

ADDITIONAL TROUBLE SHOOTING

Symptom

Remedy

Fire Pit 

Won’t Light

1. Bleed gas line.

2. Ensure all gas lines are turned ON.

3. Ensure there is not too much media overtop the burner, it can inhibit the  

 

 

 

    gas flow.  Too little or no media can also contribute to non-lighting.

4. Check alignment of thermocouple (TC) over rainshield on page 24, Fig. 31.  Adjust if needed.

5. Check batteries in battery pack.  Minimum total voltage to operate should be 5.3 volts.

No Spark to 

Ignite

1. Visually look at ignitor for any physical damage.

2. Ensure batteries are not installed backwards in battery pack. Check min. voltage of 5.3 volts. 

3. Ensure battery in transmitter is not installed backwards and at minimum voltage of 9.0 DCV.

Continues to 

Spark after 

Lighting

1. Thermocouple out of alignment.

2. Check connection of thermocouple at “S” terminal on control module to ensure it is connected.

Low Flame

1. Ensure the base media is at least 1 to 2-inch in diameter and top media is no more than 1-inch

    over top of burner.

2. Ensure all shut-off valves and valve is fully open.  

3. Check for spider webs inside burner orifice.

Water in my

Fire Pit

1. Excess dust/sand material from media may be blocking the weep holes to relieve water.  Remove

 all media and unplug weep holes.  Clean or install new media free of dust and dirt.

2. Ensure fire pit enclosure has proper drainage for water and proper ventilation to dry out.

3. Recommend to purchase a cover/lid to keep excessive water out of the fire pit.

Whistling Noises 1. Check media to ensure it is not too tightly packed around the burner tube.

2. Ensure a non-whistling flex connector is being used.

Fire Pit Won’t 

Stay Lit

1. Check alignment of thermocouple over rainshield on page 24, Fig. 31.

2. Thermocouple reading should be between 10-20mV.  Test at the brass ground lead on gas valve

    and the gold lead at “S” terminal on the control module. If no minimum millivolts are maintained 

   replace the TC.

3. Check continuity of thermocouple.  Using a volt meter remove the TC test lead “S” from the 

    control module and the brass fork terminal from the gas valve.  Test for continuity.  If no continuity

   then replace the TC.

4.  Ensure thermocouple is clean and free of any debris.  Excessive soot can be an issue.

FIRE PIT MAINTENANCE 

1.  The fire pit should be inspected and cleaned before initial use at least annually by a qualified field service person.

2.  Any component that is found faulty must be replaced with an approved component.

3.  Any tampering or modifying with the fire pit is dangerous and voids all warranties.

4.  During winter months in cold climates and various seasons operation the fire pit may be affected by weather          

 

    conditions.  It is recommended to use a ventilated cover overtop of your fire pit to protect it from humid/rainy weather    

    conditions when not in use.  Heavy rains/downpours could affect the fire pit operation if not covered; if this

    occurs ensure you allow the fire pit time to dry out before attempting to operate.  

NOTE

: If a combustible type cover is        

    used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard.

5.  Carbon (soot) may build up on the surface of logs (if installed) during heavy use.  Sooting may also occur periodically    

     on the screen of the ignitor hood.  To clean, brush off with a dry bristle brush or cloth.  Keep soot away from clothing or   

     furniture.  

6.  Over time stainless steel parts can discolor when heated, usually a golden or brown hue.  This discoloration is normal    

     and does not affect the performance of the appliance.

SECTION C THERMOCOUPLE  FLAME SENSE (TFS) INST

ALLA

TION

f i r e - p a r t s . c o m

Summary of Contents for Firegear Outdoors FPB-25SFBSMT-N

Page 1: ...t Disc TFS system FPB 25SFBSTFS P FPB 30SFBSMT N 30 Square Flat Disc MT system FPB 30SFBSMT P FPB 30SFBSTMSI N 30 Square Flat Disc TMSI system FPB 30SFBSTMSI P FPB 30SFBSTFS N 30 Square Flat Disc TFS...

Page 2: ...nt DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicini...

Page 3: ...rial due to rapid temperature differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of...

Page 4: ...B 30SFBSTMSI N FPB 30SFBSTMSI P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 30SFBSTFS N FPB 30SFBSTFS P 1 16 30 x 30 26 1 2 18 19 69 18 FPB 34SFBSMT N FPB 34SFBSMT P 1 16 34 x 34 29 1 2 18 19 69 18 FPB 34SFBS...

Page 5: ...5 0 WC 10 5 WC Table 3 Gas Pressures Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC for Liquid Propane LP at the burner orifice Flex line size and proper gas pipe sizing will...

Page 6: ...the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure Th...

Page 7: ...n of the stainless steel flex gas line supplied with the fire pit IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must...

Page 8: ...ION A minimum of 18 square inches of cross ventilation per side is required to keep the inside of the enclosure dry We recommend installation of a VENT KIT 6x12 See accessory section 8 These products...

Page 9: ...ns Fig s 4 5 and 6 show the use of the flex frame system which provides the ability to easily remove the disc if necessary O N O F F O N O F F Fig 4 Show disc secured under stone caps Fig 5 Show disc...

Page 10: ...se manner Secure into position See Fig 8 Fig 8 Installing OAS assembly to spur burner INSTALLING KEY VALVE The key valve contents 1 key valve 1 key and 1 flange See Fig 9 The valve requires a 1 round...

Page 11: ...ve in place Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple Key Valve Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner Key PU...

Page 12: ...6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause s...

Page 13: ...sually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance MT TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 2 Ensure all gas...

Page 14: ...y Valve Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threa...

Page 15: ...Fig 16 Installing OAS assembly to spur burner Section B Thermocouple Manual Safety TMSI Installation Fig 14 Shows disc secured under stone caps Fig 15 Shows disc secured between layer of block NOTE A...

Page 16: ...e gas valve is secured into the mounting plate with a nut Fig 17 shows an example of a typical installation Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner OFF Gas Valve TC Wire Pie...

Page 17: ...ter than 1 inch overtop of the burner portholes Do NOT cover the screen mesh with any rock or glass It must be free an any debris to operate properly It is important check that the ignitor probes be p...

Page 18: ...disconnected from its fuel supply Natural or LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance Fig 21 C...

Page 19: ...ally a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TMSI TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 3 Ensure all gas...

Page 20: ...s on all male NPT threads not flared fitting side Ensure all connections are tight and check for gas leaks before and after assembly is complete REV 1 4 19 Flare to 3 8 Male Thread Fitting Not Supplie...

Page 21: ...ustrations below show examples of possible installations NOTE Additional methods of supporting the center of the disc underneath or supporting an oversized opening are shown on page 9 in Figs 6 7 Requ...

Page 22: ...smitter and you will see a red LED light at the top of the transmitter glow The red LED light will only be lit when a button is pushed See Fig 27 Fig 26 Weatherproof cover lid installation INSTALLING...

Page 23: ...A maximum of three 3 codes can be programmed to the module After a total of three 3 codes have been pro grammed the memory is full and will not accept any additional codes To clear all codes press and...

Page 24: ...f Cover ON O F F Gas valve and flexible gas lines are supplied gas shut off is not supplied but available in accessories page Flex lines with flared fittings do not require Teflon tape or pipe compoun...

Page 25: ...operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS NOTE It may take several cycles of ON OFF to purge the airflow from the gas lines...

Page 26: ...w for proper flame sensing 5 Ensure orange white leads from module are plugged into the PILOT connection on the valve body 6 Ensure green white leads from module are plugged into the MAIN connection o...

Page 27: ...bstruction between the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system...

Page 28: ...ouple over rainshield on page 24 Fig 31 2 Thermocouple reading should be between 10 20mV Test at the brass ground lead on gas valve and the gold lead at S terminal on the control module If no minimum...

Page 29: ...ack Wire Flat Disc Pan Spur Burner Ignition Hood 7 8 Washer Brass Nut OAS NG Burner Orifice Coupler T 200 9898 46 Flex Conector Note Use joint compound or Teflon tape resistant to all gasses on all ma...

Page 30: ...OT 10 11 12 13 Remote Off S I ADJ IPI POWER Learn AUX 17 19 AA Batteries AA Batteries AA Batteries AA Batteries 20 5 7 LOW HI OFF ON 25 4 6 O N O F F 15 14 16 22 23 24 28 29 18 30 36 37 38 21 Requires...

Page 31: ...rome Plated Key 1 KEY PC 12 x 13 Chrome Cover Plate 1 CVR BVL2CP x 14 Thermocouple for TFS Pilot Must be ordered with item 15 1 ST3 040 1023 x 14 Thermocouple for TMSI Pilot 1 ST3 040 1025 x 15 Thermo...

Page 32: ...eld Replacement Kit not shown 1 TFS IGNT ASSEMBLY x 40 Thermocouple Rainshield Replacement Kit not shown 1 TMS TC ASSEMBLY x 41 Manual Spark Ignitor Module not shown 1 3042 RB x 42 23 Piezo Extension...

Page 33: ...x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare Adapter Model ADP10 OUT 10 wire ADP70 OUT 70 wire Outdoor approved 7 5VDC adapter transformer elimi...

Page 34: ...cation or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemical...

Page 35: ...n to be easily read Note Mounting plate can also be installed into a paver control panel PAVER CP TMSI bracket system Using scissors carefully cutout the template and trace it on your concrete board T...

Page 36: ...IGHT Position 2 Position 1 Position 3 The TMS valve bracket can be oriented in different positions to accommodate different installations Once the bracket and knob are installed the knob may not be or...

Page 37: ...REV 1 8 19 Page 37 Square Flat Disc Fire Pits NOTES fire parts com...

Page 38: ..._____ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 Wh...

Reviews: