REV. 1-8-19 Page 24
Square Flat Disc Fire Pits
IGNITOR ALIGNMENT
It is important check that the ignitor probes be properly
aligned overtop of the burner port holes and did not move
during shipping. Use the Fig. 31 as a guide. Before lighting
remove the screen cover of the ignition hood to burner and
ensure the spark probes are directly overtop of a burner port
hole. The sparking probes and the thermocouple must be in
the path of a flame to ignite the gas for proper ignition of the
flame. Replace the screen cover and follow the operating
instructions.
Fig. 31
Proper alignment of probes and thermocouple
.
Thermocouple
1/8” Gap at Ignitor Probes
Igniton
Hood
⅛”
Gas Supply
Flat Disc
Non-Combustible Enclousure
Key Valve
Spur Burner
Valve Box
Battery Pack
(Weatherproof Cover)
ON
OFF
Gas valve and flexible gas lines are supplied; gas shut-off is not supplied, but available in accessories page. Flex lines
with flared fittings do not require Teflon tape or pipe compound. Ensure not to “kink” the flex lines to allow better gas flow
of gas. The illustration above is only a guide for the gas connection. Local codes may require different methods to
connect the gas supply.
CONNECTING GAS SUPPLY
Connect the gas supply line to the bottom of the valve box with the supplied flex connector
as shown in Fig. 32 below. If necessary remove the lid for greater access to the connection. Ensure you have enough
flex line available to pull the fire pit out of the enclosure if needed for maintenance or service.
NOTE:
If removing lid,
ensure you slide the flex line through the lid access hole to enable you to reattach the lid.
SECTION C THERMOCOUPLE FLAME SENSE (TFS) INST
ALLA
TION
Fig. 32
Shows TFS system installed into an enclosure.