COMMUNICATION – SAFETY – TRANSMITTER – (C/S – TX)

This SKYTECH series remote controls have a COMMUNICATION – SAFETY function built into the software. It provides 

an extra margin of safety when the TRANSMITTER is out of the normal 20-foot operating range of the receiver.

The COMMUNICATION – SAFETY feature operates in the following manner for all OPERATING MODES:  ON/THERMO/

PROGRAM.

At all times and in all OPERATING MODES, the transmitter sends an RF signal every fifteen (15) minutes, to the receiver, 

indicating that the transmitter is within the normal operating range of 20-feet.  Should the receiver NOT receive a transmit-

ter signal every 15 minutes, the IC software, in the RECEIVER will begin a 2-HOUR (120-minute) countdown timing func-

tion.  If during this 2-hour period, the receiver does not receive a signal from the transmitter, the receiver will shut down 

the fireplace being controlled by the receiver.  The RECEIVER will then emit a series of rapid “beeps” for a period of 10 

seconds.  Then after 10 seconds of rapid beeping, the RECEIVER will continue to emit a single “beep” every 4 seconds 

until a transmitter signal is again received.  The intermittent 4 second beeping will go on for as long as the receiver’s bat-

teries last which could be in excess of one year.  

 

 

 

 

 

 

 

 

 

 

 

To “reset” the RECEIVER and operate the fireplace system, you must press the MODE button on the transmitter.  The 

word ON must display on the LCD screen.  By turning the system to ON, the COMMUNICATION SAFETY operation is 

overridden and the system will return to normal operation depending on the MODE selected at the transmitter.

The COMMUNICATION SAFETY feature will reactivate should the transmitter be taken out of the normal operating range 

or should the transmitter’s batteries fail or be removed.

GENERAL INFORMATION

PROGRAM OPERATION OF THE TRANSMITTER

The transmitter has a built-in factory program, (7) days a week 

with (4) continuous time periods for each day. Each time period 

has it’s own starting time and temperature.  A chart of the built- 

in programs is at the right.  

NOTE

: The ending time for one 

period is the starting time for the next period.

You may change any of the factory settings by following the 

procedures below.  Should you desire to return to the factory 

program, follow the procedures under heading 

PROGRAM 

REVIEW

 or 

PROGRAM CANCELLATION.

Skytech: 3301P

REV. 2-7-12  Page 8 

PROGRAMMING THE TRANSMITTER TO YOUR CUSTOM SETTINGS

The transmitter built-in program is exactly the same for everyday of the week.  If desired, you may change a single day 

or all seven (7) days of the built-in program. Use the blank table on the next page and fill in your customized settings. To 

change one or all seven days open the transmitter front cover and complete the following steps:

STEP 1

:  Press the PROG button for 4 seconds and release.  

The words 

START

 and 

For 

will begin to blink (Fig. 20).  The 

current DAY, PERIOD, TIME and SET temperature of the built-in 

factory program will also be displayed.

To program the 

DAY

 and 

PERIOD OF DAY

, press the AHEAD 

or BACK buttons to display the DAY and PERIOD you wish to 

program. When you have reached the correct DAY and PERIOD 

OF DAY push the PROG button and the 

TIME

 will blink on the 

LCD screen (Fig. 21).

DOWN

UP

MODE

SET

PROG

AHEAD

BACK

TIME

TIMER

COVER OPEN

Built -in 

Factory 

Program

Period

Time/Temp

ON

Time

OFF

All 7 Days

Morn

6:00AM / 70° 8:30AM

Day

8:30AM / 60° 3:00PM

Eve

3:00PM / 70° 11:00PM

Night 

11:00PM / 63° 6:00AM

Fig. 19 Built-in Factory Program

Fig. 20 Setting Day and Period of Day

BUILT-IN PROGRAM

Summary of Contents for 3301P

Page 1: ...iance when a potentially unsafe condition exists REV 2 7 12 Page 1 Skytech 3301P INITIAL SET UP OF TRANSMITTER DOWN UP MODE COVER CLOSED DOWN UP MODE SET PROG AHEAD BACK TIME TIMER COVER OPEN SMALL BU...

Page 2: ...the screen is for Sunday To change the day of the week press AHEAD or BACK buttons After confirming the day of the week press the SET button 5 After confirming day of the week the HOUR digits will beg...

Page 3: ...e is operational 13 HOLD Displays when programmed SET temperature is overridden and will hold that temperature until cancelled 14 CP Displays when CHILD PROOF LOCK OUT is engaged Pressing the UP and T...

Page 4: ...ended that 18 gauge stranded or solid wires not included be used to make connections between the terminal wiring block on the millivolt gas valve or electronic module and the wire terminals on the rem...

Page 5: ...amage the remote receiver WIRING MILLIVOLT VALVES The remote receiver must be connected to the millivolt valve at the TH TH TP thermostat terminals on the terminal block on the millivolt gas valve Con...

Page 6: ...flame should extinguish the pilot flame will remain on Press the MODE button on the transmitter to change the system to THERMO Advance the SET temperature on the transmitter to a temperature of a lea...

Page 7: ...eries when exposed to a constant temperature of 115 F can lose up to 50 of their operating power When the battery cools down it will partially recharge itself but con stant heating and cooling will re...

Page 8: ...he transmitter be taken out of the normal operating range or should the transmitter s batteries fail or be removed GENERAL INFORMATION PROGRAM OPERATION OF THE TRANSMITTER The transmitter has a built...

Page 9: ...ming process if you only want to program only specific days you can bypass the DAYS and PERIOD of DAY by pushing the AHEAD or BACK buttons This eliminates the need to enter the TIME and TEMPERA TURE f...

Page 10: ...6 C 3 The TRANSMITTER will monitor the room temperature every 2 minutes automatically turning fireplace ON or OFF thermostatically DOWN UP MODE SET PROG AHEAD BACK TIME TIMER COVER OPEN Fig 25 Thermo...

Page 11: ...e has expired 4 To cancel the TIMER operation press the TIMER TIME button for more than 2 seconds OPERATIONAL NOTE When the TIMER is used in the THERMO mode the THERMO operation will be disabled until...

Page 12: ...o prevent repeated thermo cycling of gas appliance the sensing unit in the transmitter will only activate the remote receiver when temperature change exceeds 2 F 1 C above or below the SET desired tem...

Page 13: ...ADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT SPECIFICATIONS BATTERIES Transmitter 3 0V 2 e...

Page 14: ...batteries 3 Press Small button 4 Replace batter cover All remaining programming wil be made from the front of the transmitter now 1 2 3 4 OPERATION Press MODE button on TRANSMITTER to change operating...

Page 15: ...m START TIME by pressing UP or DOWN button 4 Again press PROG button SET TEMP will begin to blink Program SET TEMP by pressing UP or DOWN buttons 5 Again press PROG button The next DAY OF WEEK and PER...

Page 16: ...efective workmanship or materials Damage to the SYSTEM caused by accident misuse abuse or installation error whether performed by a contractor Service Company or owner is not covered by this warranty...

Page 17: ...appliance into the receiver push the ON button on the transmitter and you are in business It s that easy The list price of 29 95 for the Santa s Helper has been cut almost in half to 15 00 USD for th...

Reviews: