CHECKING THERMO OPERATION
The operation of the Thermo setting can be checked on demand by adjusting the SET temperature 2°F above or below the
room temperature, which will cause the system to turn ON or OFF, respectively. Normally, however, the system will only
respond to temperature changes every two minutes. NOTE: If “SWING” number has been changed, then activation will
occur at the new “SWING” setting. See pages 11 and 12 for more temperature SWING information.
When the gas fireplace system is activated, a FLAME icon will display on the LCD screen indicating a signal has been sent
from the transmitter.
THERMO MODE OPERATION
(System operates as a thermostat based on the SET temperature only)
SETTING DESIRED ROOM TEMPERATURE
This remote control system can be thermostatically controlled when
the transmitter is in the THERMO mode.
1. To set the DESIRED room temperature, press the MODE
button on the transmitter until the word THERMO is visible on
the LCD screen. The larger number in the center of the screen is
the room temperature and the smaller number on the right side
is the SET temperature.
.
2. Press the UP or DOWN button to select the DESIRED room temperature. The highest SET temperature is 99°F
(32°C). The lowest SET temperature is 45°F (6°C).
3. The TRANSMITTER will monitor the room temperature every 2 minutes automatically turning fireplace ON or OFF
thermostatically.
DOWN
UP
MODE
SET
PROG
AHEAD
BACK
TIME
TIMER
COVER OPEN
Fig. 25 Thermo on Mode
SET TEMPERATURE OVERRIDE
– (PROGRAM mode only)
The user may change the current SET temperature without chang-
ing the programs stored in the transmitter’s memory. The OVER-
RIDE feature will be automatically cancelled at the start of the next
PROGRAM PERIOD.
1. To change current SET TEMPERATURE, press the UP or DOWN
button (Setting will be cancelled automatically when next program
period begins.) The word OVERRIDE will appear over the SET
frame on the LCD screen.
2. To cancel temperature OVERRIDE, press SET button.
SET TEMPERATURE HOLD
– (PROGRAM mode only)
The user may override the SET temperature during any period, adjust-
ing the SET temperature to a CONSTANT new SET/HOLD tempera-
ture.
1. Press the UP or DOWN button to change the SET temperature to
the level desired. The word OVERRIDE will appear in SET frame
on the LCD.
2. To HOLD the new temperature at a CONSTANT setting, push the
UP and DOWN buttons “
at the same time”
to activate the HOLD
function. The word HOLD will appear over the SET frame and the word OVERRIDE will disappear.
3. To cancel OVERRIDE or HOLD, press the SET button.
DOWN
UP
MODE
SET
PROG
AHEAD
BACK
TIME
TIMER
COVER OPEN
Fig. 26 SET Temperature Override
DOWN
UP
MODE
SET
PROG
AHEAD
BACK
TIME
TIMER
COVER OPEN
Fig. 27 Set Temperature Hold
TRANSMITTER OPERATING MODES