CHECKING THERMO OPERATION

The operation of the Thermo setting can be checked on demand by adjusting the SET temperature 2°F above or below the 

room temperature, which will cause the system to turn ON or OFF, respectively.  Normally, however, the system will only 

respond to temperature changes every two minutes.  NOTE:  If “SWING” number has been changed, then activation will 

occur at the new “SWING” setting. See pages 11 and 12 for more temperature SWING information.

When the gas fireplace system is activated, a FLAME icon will display on the LCD screen indicating a signal has been sent 
from the transmitter.

THERMO MODE OPERATION 

(System operates as a thermostat based on the SET temperature only)

SETTING DESIRED ROOM TEMPERATURE

This remote control system can be thermostatically controlled 

when the transmitter is in the THERMO mode.

 

1.  To set the DESIRED room temperature, press the MODE          

      button on the transmitter until the word THERMO is visible on  

      the LCD screen. The larger number in the center of the screen  

      is the room temperature and the smaller number on the right   

      side is the SET temperature.

.

2.  Press the UP or DOWN button to select the DESIRED room temperature.  The highest SET temperature is 99°F  

 

      (32°C).  The lowest SET temperature is 45°F (6°C).

3.  The TRANSMITTER will monitor the room temperature every 2 minutes automatically turning fireplace ON or OFF  

 

       thermostatically.

SET TEMPERATURE OVERRIDE

 – (PROGRAM mode only)

The user may change the current SET temperature without chang-

ing the programs stored in the transmitter’s memory.  The OVER-

RIDE feature will be automatically cancelled at the start of the next      

PROGRAM PERIOD.

1.  To change current SET TEMPERATURE, press the UP or  

      DOWN button (Setting will be cancelled automatically when next  

      program period begins.)  The word OVERRIDE will appear over  

      the SET frame on the LCD screen.

2.  To cancel temperature OVERRIDE, press SET button.

SET TEMPERATURE HOLD

 – (PROGRAM mode only)

The user may override the SET temperature during any period, 

adjusting the SET temperature to a CONSTANT new SET/HOLD 

temperature.

1.  Press the UP or DOWN button to change the SET temperature  

     to the level desired.  The word OVERRIDE will appear in SET  

     frame on the LCD.

2.  To HOLD the new temperature at a CONSTANT setting, push the  

      UP and DOWN buttons “

at the same time”

 to activate the HOLD  

      function. The word HOLD will appear over the SET frame and the word OVERRIDE will disappear.

3.  To cancel OVERRIDE or HOLD, press the SET button.

TRANSMITTER OPERATING MODES

Fig. 25 Thermo on Mode

AHEAD

TIMER

PROG

TIME

UP

MODE

DOWN

BA

CK

SE

T

Fig. 26 SET Temperature Override

AHEAD

TIMER

PROG

TIME

UP

MODE

DOWN

BA

CK

SE

T

Fig. 27 Set Temperature Hold

AHEAD

TIMER

PROG

TIME

UP

MODE

DOWN

BA

CK

SE

T

Summary of Contents for 3003P

Page 1: ...potentially unsafe condition exists REV 12 7 12 Page 1 Model 3003P INITIAL SET UP OF TRANSMITTER Fig 1 Transmitter Front and Back Views 6 00AM 8 30AM 3 00PM 11 00PM 6 00AM DAY MORN EVE NIGHT 70 60 70...

Page 2: ...the week press the SET button 5 After confirming day of the week the HOUR digits will begin blinking on the screen Fig 4 Press the UP or DOWN buttons to set the hour corresponding with the AM PM time...

Page 3: ...programmed SET temperature is overridden and will hold that temperature until cancelled 14 CP Displays when CHILD PROOF LOCK OUT is engaged Pressing the UP and TIMER buttons together engage or disenga...

Page 4: ...that 18 gauge stranded or solid wires not included be used to make connections between the terminal wiring block on the millivolt gas valve or electronic module and the wire terminals on the remote r...

Page 5: ...damage the remote receiver WIRING MILLIVOLT VALVES The remote receiver must be connected to the millivolt valve at the TH TH TP thermostat terminals on the terminal block on the millivolt gas valve Co...

Page 6: ...uld extinguish the pilot flame will remain on Press the MODE button on the transmitter to change the system to THERMO Advance the SET temperature on the transmitter to a temperature of a least 2 F 1 C...

Page 7: ...atteries when exposed to a constant temperature of 115 F can lose up to 50 of their operating power When the battery cools down it will partially recharge itself but con stant heating and cooling will...

Page 8: ...itter be taken out of the normal operating range or should the transmitter s batteries fail or be removed GENERAL INFORMATION PROGRAM OPERATION OF THE TRANSMITTER The transmitter has a built in factor...

Page 9: ...days you can bypass the DAYS and PERIOD of DAY by pushing the AHEAD or BACK buttons This eliminates the need to enter the TIME and TEMPERA TURE for specific each DAY and PERIOD speeding up the program...

Page 10: ...3 The TRANSMITTER will monitor the room temperature every 2 minutes automatically turning fireplace ON or OFF thermostatically SET TEMPERATURE OVERRIDE PROGRAM mode only The user may change the curren...

Page 11: ...or more than 2 seconds OPERATIONAL NOTE When the TIMER is used in the THERMO mode the THERMO operation will be disabled until the countdown time has expired then normal THERMO mode will presume LOW BA...

Page 12: ...smitter will only activate the remote receiver when temperature change exceeds 2 F 1 C above or below the SET desired temperature However if the SWING setting has been changed from the factory setting...

Page 13: ...TY TO OPERATE THE EQUIPMENT SPECIFICATIONS BATTERIES Transmitter 3 0V 2 ea AAA 1 5V Alkaline Remote Receiver 6V 4ea AA 1 5 Alkaline FCC ID No s transmitter K9L3301TX receiver K9L301RX Operating Freque...

Page 14: ...maining programming wil be made from the front of the transmitter now 1 2 3 4 OPERATION Press MODE button on TRANSMITTER to change operating functions INITIAL SET UPSET FUNCTIONS USING BUTTONS ON FRON...

Page 15: ...T TIME by pressing UP or DOWN button 4 Again press PROG button SET TEMP will begin to blink Program SET TEMP by pressing UP or DOWN buttons 5 Again press PROG button The next DAY OF WEEK and PERIOD OF...